Trigger LEVEL control (30)
Mid rotation
HOLDOFF control (29)
NORM (fully CCW)
2. Use the corresponding Vertical POSITION control (17) or (18) to set trace near mid
screen.
3. Connect the signal to be observed to the corresponding INPUT connector (9) or (10),
and adjust the corresponding VOLTS/DIV switch (13) or (14) so the displayed signal
is totally on screen.
CAUTION ; Do not apply a signal
Greater than 250 V (DC + peak AC)
4. Set the A TIME/DIV switch (22) so the desired number of signal cycles are displayed.
For some measurements just 2 or 3 cycles are best ; for other measurements 50-100
Cycles appearing like a solid band works best. Adjust the Trigger LEVEL control
(30) if necessary for a stable display.
5. If the signal you wish to observe is so weak that even the 5 mV position of the VO-
LTS/DIV switch cannot produce sufficient trace height for triggering or a useable
display, pull the corresponding VARIABLE control knob(PULL X 5 MAG switch)
(15) or (16) This produces 2
㎷
/div sensitivity when the VOLTS/DIV switch is set
to 10
㎷
, and 1
㎷
/div when it is set to 5 mV. However, the channel bandwidth
decreases to 20MHZ, and the trace noise may become noticeable when this is done.
6. If the signal you wish to observe is so high in frequency that even the 01 uS position
of the A TIME/DIV switch results in too many cycles displayed, pull the A
VARIABLE knob to activate the PULL X 10 MAG switch (25).
This increases the effective sweep speed by a factor of ten, so 01 uS becomes 10
nS/div, 0.2
㎲
become 20 ns/div, etc.
7. If the signal you wish to observe is either DC or low enough in frequency that AC
coupling attenuates or distorts the signal, flip the AC/GND/DC switch (11) or (12) to
DC.
CAUTION : If the observed waveform is
low-level AC, make certain it is not
riding on a high-amplitude DC voltage.
You will also have to reset the Trigger MODE switch (27) to NORM if the signal
frequency is below 25 Hz, and possibly readjust the Trigger LEVEL control (30).
Free Datasheet http://www.datasheet4u.com/
Содержание OS-5060A
Страница 1: ...Oscilloscope Analog Oscilloscope Operation Manual Free Datasheet http www datasheet4u com ...
Страница 2: ...Oscilloscope Analog Oscilloscope Operation Manual Free Datasheet http www datasheet4u com ...
Страница 13: ...12 Free Datasheet http www datasheet4u com ...
Страница 22: ... a PROBE b EGGECTS OF PROBE COMPENSATION FIGURE 2 2 PROBE COMPENSATION Free Datasheet http www datasheet4u com ...
Страница 27: ...FIGURE 2 3 USING THE TV SYNC SEPARATOR Free Datasheet http www datasheet4u com ...
Страница 30: ...FIGURE 2 4 TRIGGER SLOPE SELECTION Free Datasheet http www datasheet4u com ...
Страница 35: ...FIGURE 2 5 SWEEP MAGNIFICATION BY THE B TIME BASE Free Datasheet http www datasheet4u com ...
Страница 43: ...FIGURE 2 8 TIME INTERVAL MEASUREMENT Free Datasheet http www datasheet4u com ...
Страница 49: ...FIGURE 2 11 RISETIME MEASUREMENT Free Datasheet http www datasheet4u com ...
Страница 51: ...4 DIAGRAMS 4 1 EXTERNAL VIEWS Free Datasheet http www datasheet4u com ...
Страница 52: ...4 2 BLOCK DIAGRAMS Free Datasheet http www datasheet4u com ...
Страница 53: ...The specifications are subjected to change without notice Free Datasheet http www datasheet4u com ...