EZ-CLONE MAG450 Скачать руководство пользователя страница 2

WARNING

•  Risk of electric shock - This pump is supplied with a grounding 

conductor and  grounding type attachment plug. To reduce 

risk of electric shock, be certain that it is connected only to 

properly grounded, grounding-type receptacle.

•  Risk of Electric Shock, Do not remove cord and strain relief. 

Do not connect conduit to pump.

•  This Pump Has Been Evaluated for Use With Water Only

•  Reduce risk of electric shock during operation of this pump 

requires the provision of acceptable grounding.

•  Risk of electric shock – This pump has not been investigated 

for use in swimming pool or marine areas

•  Do not connect to any voltage other than that shown on the 

pump.

•  Always disconnect from electrical outlet before handling the 

pump.

•  Don’t operate without water.

•  Operate pump completely submerged for proper cooling.

PERFORMANCE 

A clogged or dirty intake screen will greatly reduce performance. 

If the pump is used on a dirty surface, raise it slightly to reduce 

the amount of debris contacting the intake. If less flow is desired, 

adjust the flow control lever on the side of the pump or restrict the 

discharge flow.

Do not let the pump run when not submerged in water. Doing so 

may damage the pump. Always submerge the pump first, and then 

plug in the electrical outlet. The pump is to be supplied through a 

residual current device (RCD) with a rated residual operating cur-

rent not exceeding 30 mA.

MAINTENANCE

To clean the pump, remove the back cover and the impeller.

Use a small brush or stream of water to remove any debris 

CAUTON: The pump shaft can not be removed.

IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:

•  Check the circuit breaker and try another outlet to ensure the 

pump is getting electrical power. NOTE: Always disconnect 

from electrical outlet before handling the pump.

•  Check the pump discharge and tubing for any obstructions. 

Algae build up can be flushed out with a garden hose.

•  Check the inlet to ensure it is not clogged with debris.

•  Remove the pump inlet to access the impeller area. Turn the 

rotor to ensure it is not broken or jammed.

•  Monthly maintenance will add to your pump’s life. NOTE: 

•  Ensure that the electrical cord loops below the electrical out-

let to form a “Drip Loop” This will prevent water from running 

down the cord into the electrical outlet.