Intelligent pulse battery charger AP-800
HOW AND WHEN TO USE THE BURST CHARGING
When charging an
over
discharged battery which has a voltage below 6V (at
12V charger), the system does not start charging, even though the charger is
properly connected. In this case, press the "
BURST
" button on the front panel of
the charger to activate forced charging with the single-pulse. If necessary, press
the button several times, up to 100x, until a short beep is heard and a voltage of
6V is reached
at 12V charger
(For the other chargers, see table below).
From then on the
system automatically starts charging.
Charger model:
AP-800 12V AP-800 24V AP-800 36V AP-800 48V AP-800 60V AP-800 72V
Start charge at:
6V
12V
18V
24V
30V
36V
OPERATIONAL PROBLEMS
Error
Cause
Solution
The charger is connected to the mains,
power switch is ON. LED not flashing.
- there is no able mains voltage 230Vac
- ensure supply voltage
230Vac
Battery is connected but the charger is not
charging, all LED blinking.
- to low voltage on the battery (Over-
discharged battery)
- press BURST button
Red LED is on.
- devices has overheated due to high
ambient temperatures
- fan error
- decrease temp. of
environment
- service intervention
- clean up fan
WARNING!
•
The charger is
designed
for indoor use (do not expose the charger to rain).
•
Charger AP800 48V/14A can not use unauthorized person!
•
During charging ensure adequate ventilation!
•
Never hold with hand red and black cro and – and push BURST
button!
•
We recommend disconnecting the battery from the car if the CaCaWET or
Traction charging program is used.
•
The charger AP-800 has a built-in security feature that prevents the automatic
charging start if charger detects
an
over-discharged battery.
Over-discharged
battery could be in damage.
Therefore, the charger will start only if you press
the
»Burst button«
Sometimes it is necessary to press it several times,
up to
100x, until a voltage of 6V is reached
at 12V charger (For the other chargers,
see technical data), then the system automatically starts charging.
From this
moment on, the user is obliged to control the charging of batteries.
Because in case of a defect on the battery, it can overheat, begin to gasify
and in extreme cases may happen an explosion and /or a fire.
6