3=Horiz Curtain
4=Diagonal
5=Diamond
6=Arrow Left
7=Arrow Up
“TTnnn”
Set Transition time to
nnn. Where nnn=:
000
250
54,54,30,30,38
Set transition time to 8 frames.
“HTnnn”
Set Hold time to nnn.
Where nnn=:
000
250
48,30,30,38
Set hold time to 8 frames.
“TK”
Start Auto transition.
(TAKE)
54,4B
A response will occur within 100mS of the command. The responses are as
follows:
Response
Meaning
Hex string
“OK”
Command was understood and will implement.
4F,4B
“E0”
Command timed out.
45,30
“E1”
Error 1. Unknown command.
45,31
“E2”
Error 2. Next Logo number is not in range.
45,32
“TF”
This indicates that a transition has ended. The
user should look for this after a “TK” command
and not issue any more commands until this is
received.
4.3
geNETics Automation Protocol Parameter table.
This is the Automaticlly extracted parameters for the MW-3EM. This is used for
the generic geNETics automation protocol. See etherbox manual for a full
description of its usage.