3.7
Fuse Rating
The XN3 is fitted with a single resettable fuse on the Live circuit, of either 750mA
for AC input units or 2.5A for DC input.
If there is a power fault, the fuse may activate in which case power should be
removed from the unit and reapplied.
3.8
External Overcurrent Protection
The XN3 should be installed on a circuit with a double-pole circuit breaker of a
maximum rating of 25A. This is the maximum current rating of the smallest
internal chassis earth bond in accordance with EN60950-1 2.6.3.3. Refer to
Extronics if it becomes necessary to exceed this rating.
3.9
Data Connections
3.9.1
Copper Ethernet
Information
Check that the line speed of the switch port to which the
XN3 is connected matches the XN3 port configuration,
otherwise communication may not be established.
If Copper Ethernet is specified, this will be terminated in a standard CAT5E RJ45
Socket on the front plate of the XN3, Position D in Figure 6. Typically, the interface
will be an IEEE 10/100/1000BaseT format, but this is dependent on the access
point installed.
Terminate the RJ45 plug as follows (EIA 568B standard), Figure 8:
3.9.2
Power-Over-Ethernet (POE)
If Power-Over-Ethernet (POE) is used, the format will depend on the access point
installed in the XN3. Ensure that the correct Power Sourcing Equipment (PSE) is
used. Connect the RJ45 cable per Section 3.9.1.
Pin Function
1
OE/WE
2
OE
3
GN/WE
4
BE
5
BE/WE
6
GN
7
BN/WE
8
BN
Figure 8: RJ45 CAT5E EIA 568B Plug Wiring
Содержание iWAP XN3 X2000
Страница 1: ...INSTALLATION AND OPERATING MANUAL ...
Страница 11: ...XN3 Installation and Operating Manual 11 Figure 1 Aluminium Enclosure Mounting Dimensions ...
Страница 24: ...XN3 Installation and Operating Manual 24 6 Technical Data ...
Страница 28: ...XN3 Installation and Operating Manual 28 9 EU Declaration of Conformity ...
Страница 29: ...XN3 Installation and Operating Manual 29 ...