Warning Do not exceed the Effective Isotropic Radiated Power (EIRP) for the gas
group in which the iANT2xx will be operating. The RF output of the
transceiver will vary depending on the hardware and antenna used. The
maximum hardware limit of the access point must be used to calculate
the EIRP
–
software control by the user of the RF power is not allowed
- Group IIC
–
2W (+33dBm)
- Group IIB
–
3.5W (+35.4dBm)
- Group IIA/I/III
–
6W (+37.7dBm)
Refer to Table 1 for specific antenna details.
Important
iANT2xx are only certified for use in ambient temperatures in the ranges
specified in Table 1 and should not be used outside this range.
Important Do not exceed the Effective Isotropic Radiated Power (EIRP) limit for the
country / region of operation
Important
Repair of the iANT2xx shall only be carried out by the manufacturer. The
antennas contain no user-serviceable parts.