Extron electronics YCS SW6 MX Скачать руководство пользователя страница 10

YCS SW6 MX • Serial Communication

YCS SW6 MX • Serial Communication

Serial Communication, cont’d

The YCS SW6 MX switcher can be controlled by a host computer
or other control device via an RS-232 connection with a protocol
of 9600 baud, 1 stop bit, no parity, and no flow control.  The
control device can use either Extron’s Simple Instruction Set
(SIS) or the graphical control program for Windows.

The rear panel RS-232 9-pin D connector has the
following pin assignments:

Pin

Description

1

Input #1

2

Transmit data

3

Receive data

4

Input #2

5

Ground

6

Input #3

7

Input #4

8

Input #5

9

Input #6

RS-232 Programmer’s Guide

SIS commands consist of one or more characters per field.  No
special characters are required to begin or end a command
sequence.  When the switcher determines that a command is
valid, it executes the command and sends a response to the host
device.  All responses from the switcher to the host end with a
carriage return and a line feed (CR/LF = 

), which signals the

end of the response character string.  A string is one or more
characters.

Switcher-initiated messages

When a local event such as an input selection occurs, the
switcher responds by sending a message to the host.  No
response is required from the host.  The switcher-initiated
messages are listed below (underlined).

(C)COPYRIGHT 1997, EXTRON ELECTRONICS YCS SW6 MX,
Vx.xx
The switcher displays the copyright message when it first
powers on.  Vx.xx is the firmware version number.

Serial Communication

DB9 Pin Locations

Female

5

1

9

6

Switcher error responses

When the switcher receives a valid SIS command, it executes the
command and sends a response to the host device.  If the
switcher is unable to execute the command because the
command is invalid or it contains invalid parameters, the
switcher returns an error response to the host.  The error
response codes and their descriptions are as follows:
E01 — Invalid input channel number (out of range)
E10 — Invalid command
E13 — Invalid value (out of range)

Using the command/response table

The table on page 3-4 lists the commands that the switcher
recognizes as valid, the responses that are returned to the host, a
description of the command’s function or the results of
executing the command, and an example of each command.
Lower case characters are acceptable in the command field only
where indicated.

Symbol definitions are shown at the beginning of the table.  An
ASCII to HEX conversion table is provided in figure 8.

Figure 8 — ASCII-to-HEX conversion table

3-2

3-3

ASCII to HEX  Conversion Table

Содержание YCS SW6 MX

Страница 1: ...3 4040 Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Ku...

Страница 2: ...artung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuc...

Страница 3: ...ront panel features 2 7 Selecting an input 2 7 Chapter 3 Serial Communication 3 1 RS 232 Programmer s Guide 3 2 Switcher initiated messages 3 2 Switcher error responses 3 3 Using the command response...

Страница 4: ...ii YCS SW6 MX Table of Contents Table of Contents cont d YCS SW6 MX 1 Chapter One Introduction Features...

Страница 5: ...The switcher can be configured to operate in either NTSC or PAL mode Inputs Six inputs are provided Four can be used as either composite video or S video and two are dedicated to composite video Built...

Страница 6: ...ard is NTSC Down Video standard is PAL 7 Input 4 pin mini DIN connectors Four 4 pin mini DIN female connectors for S video input devices Installation procedure To install a YCS SW6 MX switcher perform...

Страница 7: ...the switcher 5 Turn the switcher right side up and place it in the desired location Cabling the switcher Use high resolution cable for all video input and output connections See page A 4 for Extron s...

Страница 8: ...nused side of the adapter s RS 232 T connector 3 Plug the IR detector s male plug into the IR 20 adapter s RJ 11 female connector 4 Connect the 9VDC power supply to the IR 20 adapter 5 Position the IR...

Страница 9: ...SW6 MX Installation and Operation Installation and Operation cont d YCS SW6 MX 2 8 3 Chapter 3 Serial Communication RS 232 Programmer s Guide Universal SW Control Program Remote Contact Closure Operat...

Страница 10: ...nding a message to the host No response is required from the host The switcher initiated messages are listed below underlined C COPYRIGHT 1997 EXTRON ELECTRONICS YCS SW6 MX Vx xx The switcher displays...

Страница 11: ...S SW6 MX switcher is compatible with Windows 3 1 3 11 95 98 and NT It provides remote control of input selection Installing the software The Universal SW Control Program is contained on a single 3 5 d...

Страница 12: ...ration The RS 232 connector provides a way to control the switcher from a remote contact closure device This is made possible by using pins that are not normally used by the RS 232 interface The conta...

Страница 13: ...Video Gain Unity Bandwidth 30 MHz 3dB Crosstalk 60dB 3 58 MHz Video input Number signal type 4 NTSC PAL S video 6 NTSC PAL composite video Connectors 6 BNC female 4 4 pin mini DIN female Impedance 75...

Страница 14: ...12 SHR1 12 26 383 07 SHR1 25 26 383 04 SHR1 50 26 383 05 SHR1 75 26 383 06 SHR1 100 26 383 03 SHR1 150 26 383 08 SHR1 200 26 383 09 SHR1 250 26 383 10 SHR1 300 26 383 11 S video cable Description Part...

Страница 15: ...YCS SW6 MX Reference Information Reference Information cont d A 6...