![Extron electronics XTP T USW 103 4K Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/extron-electronics/xtp-t-usw-103-4k/xtp-t-usw-103-4k_user-manual_2457237027.webp)
XTP T USW 103 4K Switcher • SIS Configuration and Control
19
SIS Configuration and
Control
The XTP T USW 103 4K can be configured and controlled using Extron Simple Instruction Set
(SIS) commands or the XTP System Configuration Software (see
on page 27). This section contains SIS communication details and SIS commands and
responses when connected directly to an XTP T USW 103 4K. Topics in this section include:
•
•
•
Command and Response Tables for SIS Commands
Host Device Connection
Use a computer running the Extron DataViewer utility or use a control system to enter SIS
commands. To connect directly to an XTP T USW 103 4K, connect the computer to the
front panel configuration port (see
,
B
on page 16) or the rear panel RS-232
connector (see
,
H
on page 5). The protocol for the serial port is as follows: 9600
baud, no parity, 8 data bits, 1 stop bit, no flow control.
SIS Overview
Host and Device Communication
SIS commands consist of one or more characters per field. No special characters are required
to begin or end a command sequence. When the XTP T USW 103 4K determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the switcher to the host end with a carriage return and a line feed
(CR/LF =
]
), which signals the end of the response character string. A string is one or more
characters.
Unsolicited Message
When the switcher is connected through the serial port only and a local event occurs, the
device responds by sending a message to the host.
The following copyright message is displayed after a power cycle via RS-232.
(C)
Copyright
YYYY
,
Extron Electronics,
XTP T USW 103 4K V
x.xx
,
60-1550-12
]
YYYY
is the year.
V
x.xx
is the firmware version number.
Содержание XTP T USW 103 4K
Страница 6: ......
Страница 8: ...XTP T USW 103 4K Switcher Contents viii...