XMP 240 C AT • Installation
4
Installation
This section describes the installation of the XMP 240 C AT and covers the following topics:
•
•
Rear Panel Features and Cabling
•
•
Mounting
The 1U high, half rack width, 9.5 inch deep XMP 240 C AT mounts in the following manners:
•
Rack mounting
— Attach the XMP 240 C AT to a standard 19-inch rack shelf. The
following Underwriters Laboratories (UL) guidelines pertain to the installation of the
XMP 240 C AT in a rack:
•
Reduced air flow
— Install the equipment in the rack so that the amount of air
flow required for safe operation of the equipment is not compromised.
•
Mechanical loading
— Mount the equipment in the racks so that uneven
mechanical loading does not create a hazardous condition.
•
Circuit overloading
— When connecting the equipment to the supply circuit,
consider the effect that circuit overloading might have on overcurrent protection
and supply wiring. Consider equipment nameplate ratings when addressing this
concern.
•
Reliable earthing
(grounding)
— Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to power supply connections other than direct
connections to the branch circuit (such as the use of power strips).
•
Under-furniture mounting
— Mount the XMP 240 C AT under the surface of a desk,
table, or podium.
•
Free-standing
— Attach the four rubber feet provided with the device to the bottom of
the XMP 240 C AT in the four corners and place the unit on furniture as desired.
NOTE:
To mount the XMP 240 C AT using an Extron mounting kit, see the instructions
provided with the kit.