VSC 75 Serial Communication
VSC 75 Serial Communication
Remote Contr
ol, cont’d
Freeze
Set Freeze mode to On (freeze the displayed image)
F
46
Frz 1
Enable freeze
Set Freeze mode to Off (release the displayed image)
f
66
Frz 0
Disable freeze
Executive mode
Set Executive mode to On
X
58
Exe 1
Enable executive
Set Executive mode to Off
x
78
Exe 0
Disable executive
Test mode
Set Test mode to On
J
4A
Dmo 1
Enable test
Set Test mode to Off
j
6A
Dmo 0
Disable test
Firmware version, part number & information requests, and reset
System reset
Esc z
1B 7A 0D
Zap
Reset to factory default
Query firmware version number
Q/q
51/71
Ver x.xx
Display firmware version
Request part number
N/n
4E/6E
N60-321-01
Display VSC 75’s part #
Request information
Command =
I/i
49/69
(see below)
Display status
Response =
Dvt
X1
• Frz
X2
• Exe
X2
• Dmo
X2
Command/response table
Command description
Command
Response
Additional
ASCII
Hex
to host
description
Horizontal shift
Shift right one step
{ H
7B + 48
Hph +
Increment up
Shift left one step
} H
7D + 48
Hph -
Increment down
Vertical shift
Shift down one step
{ /
7B + 2F
Vph +
Increment up
Shift up one step
} /
7D + 2F
Vph -
Increment down
Horizontal size
Increase horizontal size by one step
{ :
7B + 3A
Hsz +
Increment up
Decrease horizontal size by one step
} :
7D + 3A
Hsz -
Increment down
Vertical size
Increase vertical size by one step
{ ;
7B + 3B
Vsz +
Increment up
Decrease vertical size by one step
} ;
7D + 3B
Vsz -
Increment down
Flicker/vertical filter (detail)
Select flicker/vertical filter
X1
(Dvt)
X1
d
X1
+ 64
X1
Dvt
Specific value
Select next higher flicker/vertical filter (Dhz + 1)
{ d
7B + 64
Dvt
X1
Increment up
Select next lower flicker/vertical filter (Dhz - 1)
} d
7D + 64
Dvt
X1
Increment down
3-5
3-4
Symbol definitions
= CR/LF (carriage return/line feed)
= CR (carriage return only)
• =
Space
X1
= Vertical filtering
level (1 through 2)
X2
= 1 = On, 0 = Off