VoiceLift Pro Microphones User Guide • Reference Information
32
Resetting the VLR 302
Follow the steps below to reset the VLR 302 receiver using the front panel
Reset
button
(see
on page 12). The VLR 302 may also be reset using the Product Configuration
Software (see the help file for the VLR 302 module within PCS).
NOTE:
All paired microphones must be turned off in order to properly reset the VLR 302
receiver.
Reset Mode 1
This mode resets the unit to its base factory firmware.
Hold down the
Reset
button while the switcher is being powered up. The receiver boots
to its base factory firmware. Any firmware that has been loaded over the base firmware is
ignored.
Reset Mode 2
This mode resets pairing history, but retains settings and usage data.
1.
Hold down the
Reset
button for about three seconds until the Power LED blinks once.
2.
Release and press the
Reset
button momentarily (for less than one second) within one
second.
3.
Both LINK 1 and LINK 2 LEDs flash one time, simultaneously, to confirm that the pairing
history has been cleared. Unsolicited response “
Pair00
” is sent.
Reset Mode 3
This mode is an absolute factory reset. It will default the unit back to factory settings, and
also clear pairing and usage data.
1.
Hold down the
Reset
button for about six seconds until the Power LED blinks two
times.
2.
Release and press the
Reset
button momentarily (for less than one second) within one
second.
Front panel LEDs will cycle, and all settings (including pairing history) will be cleared from the
unit. This reset is the same as sending the ‘
ZXXX
’ SIS command.