As shown below, the Extron VCM 100 AAP and VCM 100 MAAP serve to remotely control
volume and mute with Extron products (such as the
MPA 122 Mini Power Amplifier).

Extron Electronics, USA

1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500  
Fax 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040  
Fax +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400  
Fax +65.6383.4664

Extron Electronics, Japan

Kyodo Building
16 Ichibancho
Chiyoda-ku, Tokyo 102-0082 Japan 
+81.3.3511.7655  
Fax +81.3.3511.7656

www.extron.com

PO

W

ER

OU

TP

UT

S

4/8

 Oh

ms

INP

UT

S

L

R

L

R

REM

OT

E

10

V

VO

L/M

UT

E

L

MP

12

2

R

C

US

US

Projector

Audio
Output

Extron
STP 22

Cable

Extron
MPA 122

Mini Power Amplifier

MU

TE

VO

LU

ME

VC

10

0 A

AP

Extron
VCM 100 AAP

Volume/Mute Controller
(mounted in an Extron
AAP 100 Frame)

VCM 100 AAP and MAAP

Remote connector pin configuration

As shown below right, 

Pin 1

 is a 10 VDC reference voltage.  

Pin 2

 is volume and mute

control with DC voltage; the range is 0 to 10 V, where 0 V is mute and 10 V provides
maximum volume.  

Pin 3

 is ground.

All nominal levels are at ±10%.

The Extron VCM 100 AAP and VCM 100 MAAP are remote volume/mute controllers
designed to work with Extron products (such as the MPA 122 mini power amplifier).

Mounted into standard Extron AAP or MAAP mounting frames, the VCM 100 AAP and
VCM 100 MAAP each have a 10k ohm potentiometer volume control knob and mute
button.

The Mute button toggles between mute and un-mute, turning bright red to indicate
mute, and dim green to indicate un-mute.

Audio level setting procedure

To set the system level to not exceed the maximum
volume in using the VCM 100, do the following:

1.

 Reduce the power amplifier volume to minimum.

2.

 Turn the Volume knob on the VCM 100 to the

maximum position.

3.

 Slowly turn up the power amplifier volume to the

maximum undistorted sound level allowed for the
application.

MUTE

VOLUME

VCM 100 MAAP

VO

L

/

MUTE

10V

REMOTE

Red

Black

Ground

Extron
STP 22

Cable

10V
VOL/MUTE

1