Mounting the USB Extender

ATTENTION:

 

• 

Installation and service must be performed by authorized personnel only.

• 

L’installation et l’entretien doivent être effectués par le personnel autorisé 
uniquement.

The three inch deep, one inch high, quarter-rack width USB Extender transmitters and 
receivers can be placed on a tabletop, mounted on a rack shelf, or mounted under a desk 
or tabletop. The receiver can be mounted on a projector bracket. Consult the individual 
mounting kits for installation instructions.

Tabletop Placement

Affix the four included rubber feet to the bottom of the unit and place it in any convenient 
location.

Rack Mounting

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of 
these products in a rack:

1. 

Elevated operating ambient temperature 

 

If the unit is installed in a closed or 

multi-unit rack assembly, the operating ambient temperature of the rack environment 
may be greater than room ambient temperature.  Therefore, install the equipment in 
an environment compatible with the maximum ambient temperature (Tma: +122 °F, 
+50 °C) specified by Extron.

2. 

Reduced air flow 

— Install the equipment in the rack so that the equipment gets 

adequate air flow for safe operation.

3. 

Mechanical loading 

— Mount the equipment in the rack so that uneven mechanical 

loading does not create a hazardous condition.

4. 

Circuit overloading 

— Connect the equipment to the supply circuit and consider the 

effect that circuit overloading might have on overcurrent protection and supply wiring.  
Consider the equipment nameplate ratings when addressing this concern.

5. 

Reliable earthing (grounding) 

— Maintain reliable grounding of rack-mounted 

equipment.  Pay particular attention to supply connections other than direct 
connections to the branch circuit (such as the use of power strips).

Rack Mounting Procedure

The USB Extenders are in three inch deep, quarter rack width, one inch high metal 

enclosures. To find an appropriate rack mount system for your installation, go to the product 

page at 

www.extron.com

.

To mount the USB Extender, follow the instructions provided with the accessories.

Under-furniture Mounting

The unit can be mounted under a horizontal surface using an optional Under-Desk Mount 
Kit for eighth-rack and quarter-rack width products (see 

www.extron.com

). To mount the 

USB Extenders follow the instructions provided with the mounting kit.

 

USB Extenders • Reference Information

14

Содержание USB Extender AAP Rx

Страница 1: ...USER MANUAL Twisted Pair Extender for USB Peripherals USB Extenders User Guide USB for Pro A V Series 68 1719 01 Rev E 01 19...

Страница 2: ...encia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur...

Страница 3: ...IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVault PowerCage PURE3 Quantum SoundField SpeedMount SpeedSwitch System INTEGRATOR TeamWork TouchLink V Lock VN Matrix V...

Страница 4: ...ference to radio communications Operation of this equipment in a residential area is likely to cause interference This interference must be corrected at the expense of the user NOTES This 1st paragrap...

Страница 5: ...device responses mentioned in this guide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the...

Страница 6: ...ing Options Overview 5 Connections 6 Transmitter Rear Panel 6 Operation 8 Transmitter Front Panel Indicators 8 Receiver Front Panel Indicators 9 Cabling and Setup 10 System Operation 12 Troubleshootin...

Страница 7: ...USB Extenders Contents vi...

Страница 8: ...ron Electronics USB Extender Tx Rx USB Extender AAP Tx Rx and the USB Extender D decorator style Tx Rx transmitter and receiver Additional information can be found on the Extron Electronics website at...

Страница 9: ...er system consists of a transmitter Tx and a receiver Rx The transmitter connects directly to a USB port on a PC or USB host The receiver features a four port USB hub to connect multiple peripheral de...

Страница 10: ...d with each transmitter and each receiver USB Extender AAP and Decorator Style Tx Rx The AAP and decorator style versions have an RJ 45 rear connector in a single gang plate size enclosure Figure 2 US...

Страница 11: ...equired 5 Apply power to the USB extenders If external supplies are used with the transmitter and receiver both power LEDs and both LINK LEDs light to indicate proper link cable connection between the...

Страница 12: ...Installation and service must be performed by authorized personnel only L installation et l entretien doivent tre effectu s par le personnel autoris uniquement Connection Guidelines The USB Extenders...

Страница 13: ...e in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the...

Страница 14: ...see figure 4 has a DC power input twisted pair link connection and also has four female USB Type A hub connectors AAP and decorator style receivers have the hub connectors on the front panel HUB 1 2 3...

Страница 15: ...OST HOST ACTIVITY LINK HOST G B H B I G H I G H I Figure 5 Front Panel Indicators USB Extender Transmitters B USB Host connector AAP and decorator style Tx only Connect a Type A male to mini Type B ma...

Страница 16: ...built in four port hub The connections are USB 2 0 compatible providing 5 VDC at up to 500 mA to connected USB peripherals requiring power J Power LED Lights to indicate the device is receiving power...

Страница 17: ...smitter Receiver UTP or STP CAT5 or better cable Terminate both ends identically in accordance with either the TIA EIA T 568A or the TIA EIA T 568B wiring standard Figure 7 USB Extender Connection Gui...

Страница 18: ...o the receiver and apply power The Power LED on the front panel of the receiver lights NOTE The transmitter Power LED and both Link LEDs remain dark 3 Connect a Type A B USB cable Type A male to mini...

Страница 19: ...nsmitter and receiver Power LEDs Link LEDs and Host LEDs are lit The hub LED for each connected peripheral recognized by the host PC is also lit Front panel LEDs are also useful for troubleshooting Th...

Страница 20: ...A T 568B wiring standard Figure 9 shows the recommended termination of TP cables with RJ 45 connectors NOTE Terminate both ends of a cable identically in accordance with either the TIA EIA T 568A or t...

Страница 21: ...ed by Extron 2 Reduced air flow Install the equipment in the rack so that the equipment gets adequate air flow for safe operation 3 Mechanical loading Mount the equipment in the rack so that uneven me...

Страница 22: ...ders on a projector mount follow the instructions provided with the mounting kit Wall mounting The USB Extender AAP and decorator style transmitter and receiver can be installed in an electrical wall...

Страница 23: ...duits before installing the wall plate NOTE The decorator style series is designed to mount in a standard single gang wall box 1 6 in 4 1 cm 1 4 in 3 6 cm One Gang Junction Box 2 5 in 6 4 cm TP Cable...

Страница 24: ...pe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg...

Отзывы: