TP T 15HD 45 and TP T A 45 • Installation
Installation, cont’d
TP T 15HD 45 and TP T A 45
A
Appendix
Reference Information
Specifications
Parts Lists
2-8
Skew delay problems
CAT 5 TP cable can lead to registration errors between the red,
green, and blue video signals. Pair skew can be measured with
test equipment or identified by viewing a crosshatch test pattern
with a critical eye to determine if either the red, green, or blue
video image leads (appears to the left of) the other two video
images. These images can be minimized or eliminated by one
of the following methods:
•
Switch to Extron’s Enhanced Skew-Free A/V UTP cable.
•
Add a skew compensation cable equal to the length of
pair skew to the receiver’s output.
•
Install an SEQ 100 15HD Skew Equalizer on the receiver’s
video output and adjust the skew for the leading video
image.
Mounting
The TP T 15HD 45 and TP T A 45 are designed to fit into a wall-
mountable or floor box-mountable 45 mm mounting frame.
COMPUTER
INPUT
AUDIO
INPUT
The following application diagram illustrates one example of
installing these devices.