background image

Installing Modules

Several types of modules can be installed in either touchpanel Cable Cubby. However, the 
installation procedures are different, depending on modules and the touchpanel enclosure.
Each 525C module, which can be used only by the TLP Pro 525C series, can contain one of the 
following:

• 

Up to two MAAPs

• 

Up to five pass-through cables

• 

Up to two retractors

The following Series/2 modules can be used by both the TLP Pro 525C and TLP Pro 725C 
series touchpanels.

• 

Cable Cubby AC or AC + USB power modules. Power modules must be purchased 
separately. See the Extron website (

www.extron.com

) to select a power module that is 

suitable for your location.

• 

Retractor Triple Bracket, accommodating up to three retractors

• 

Series/2  Connectivity Brackets, accommodating up to three AAPs or eight pass-through 
cables.

• 

Cable Quad Brackets accommodating up to four pass-through cables.

TLP Pro 525C

The 525C modules must be installed at the ends of the TLP Pro 525C enclosure.
Extron recommends either of the possible configurations shown in figure 16, although several 
other configurations are possible.

e

e

AC Power  525C Module

Cable Quad Brackets (2) + 525C Module

Figure 16. 

Recommended Module Configurations in the TLP Pro 525C

 

TLP Pro 525C and 725C Series Touchpanels • Mounting

19

Содержание TouchLink TLP Pro 525C NC

Страница 1: ...TLP Pro 525C and 725C Series User Guide TouchLink TouchLink Pro Touchpanel Control Systems 68 3319 01 Rev D 01 20 ...

Страница 2: ...nce importantes qui se trouvent dans la documentation fournie avec le matériel Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68 290 01 sur le site Extron www extron com Istruzioni di sicurezza Italiano AVVERTENZA Il simbolo se usato su...

Страница 3: ...ipple Suppression Codec Connect DDSP Digital Display Sync Processing DMI Dynamic Motion Interpolation Driver Configurator DSP Configurator DSVP Digital Sync Validation Processing eLink EQIP Everlast FastBite Flex55 FOX FOXBOX IP Intercom HelpDesk MAAP MicroDigital Opti Torque PendantConnect ProDSP QS FPC QuickSwitch Front Panel Controller Room Agent Scope Trigger SIS Simple Instruction Set Skew Fr...

Страница 4: ... from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio and TV reception The user is cautioned that changes and modifications made to the ...

Страница 5: ...ference Safety Notices Antenna Warnings WARNING The radiated output power of the wireless device is far below the FCC radio frequency exposure limits Nevertheless the unit should be used in such a manner that the potential for human contact during normal operation is minimized To avoid the possibility of exceeding the FCC radio frequency exposure limits you should keep a distance of at least 20 cm...

Страница 6: ...ay only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved by Industry Canada ...

Страница 7: ...entation d Industrie Canada cet émetteur radio doit être utilisé uniquement avec une antenne d un certain type et d un gain maximal ou inférieur approuvé pour l émetteur par le ministère Afin de réduire les éventuelles interférences électromagnétiques préjudiciables aux autres utilisateurs il est essentiel de choisir le type d antenne et son gain de telle sorte que la puissance isotrope rayonnée é...

Страница 8: ...computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX...

Страница 9: ...sembling the Series 2 Cable Pass through Module 18 Installing Modules 19 TLP Pro 525C 19 TLP Pro 725C 22 Special Considerations for Power Modules 23 Mounting the Touchpanel Enclosure 24 Installing Cable Retractors Optional 25 On screen Menus 26 Setup Menu 26 Status 26 Network 27 Display 29 Audio 30 Advanced 31 Configuration Software 32 Configuration Software 32 Installing GUI Designer Global Confi...

Страница 10: ...TLP Pro 525C and 725C Series Touchpanels Contents x ...

Страница 11: ...WSVGA LCD touchscreen The TLP Pro 525 NC and TLP Pro 725C NC are streamlined versions of these touchpanels with a set of features designed to adhere to government and military security protocols They combine the AV system control of conventional touchpanels with the cable management convenience of the Cable Cubby They feature a tilt up full color touchscreen in an elegant metal enclosure that can ...

Страница 12: ...retraction system supports most AV data and power Included TLP Pro 525C Bracket Kit provides additional flexibility when configuring the Cable Cubby The TLP Pro 725C enclosure accommodates up to three Series 2 modules in a variety of configurations There are three different types of modules Accommodates Series 2 AC or AC USB power module plus three Retractors eight AV cables and or three AAP Archi...

Страница 13: ...ce testing for use in government applications and other mission critical environments Application Diagram Figure 1 shows one application for the TLP Pro 725C The TLP Pro 525C can be used in similar systems POWER 12V A MAX G Tx Rx RTS CTS COM 1 G Tx Rx COM 2 V C G VOL RELAYS 1 2 C 1 2 3 4 G DIGITAL I O PWR OUT 6W eBUS V S S G LAN IPCP PRO 250 IR S S G HCT 103 2 INPUTS 2 3 4 SIGNAL HDCP 3 4 HCR 102 ...

Страница 14: ...These touchpanels are not compatible with Global Configurator 3 or GUI Configurator Hardware An Extron IP Link Pro control interface must also be connected to the same network domain as the TLP Pro TouchLink panel See www extron com for a list of suitable controller processor NOTE These touchpanels are not compatible with Extron IP Link non Pro control processors TLP Pro 525C and 725C Series Touch...

Страница 15: ...o five feet from the touchpanel and at least 15 from the center axis When no motion is detected for a user defined period of time the touchpanel enters sleep mode NOTE For sleep mode to be activated the sleep timer must have been set up see Display on page 29 When motion is detected by the sensor while the display is in sleep mode the screen display is restored and active NOTES For the screen to b...

Страница 16: ...ack for the user Base Features Figure 3 shows the TLP Pro 725C base panel The TLP Pro 525C is very similar e e LAN PoE 275 mA USB RESET MENU D D D E E E A A AB B BC C C Figure 3 TLP Pro 725C Base Panel A Menu button Pressing the Menu button activates the setup menu see Setup Menu on page 26 B Reset button Pressing the Reset button allows the unit to be reset in any of three different modes and can...

Страница 17: ...hin the dedicated closet podium or desk Sauf mention contraire les adaptateurs AC DC ne sont pas appropriés pour une utilisation dans les espaces d aération ou dans les cavités murales La source d alimentation doit être située à proximité de l équipement de traitement audiovisuel dans un endroit ordinaire avec un degré 2 de pollution fixé à un équipement de rack à l intérieur d un placard d une es...

Страница 18: ...injector to the touchpanel 3 Connect the IEC power cord to a convenient 100 VAC to 240 VAC 50 60 Hz power source 3 Figure 20 shows the Extron XTP PI 100 Your power injector may look different 100 240V 50 60Hz 0 4A MAX XTP PWR XTP PWR To network switch To touchpanel 1 1 1 2 2 2 3 3 3 Figure 4 XTP PI 100 Power Injector An Extron IPL Pro control processor must also be connected to the same network do...

Страница 19: ...lso require IP address Subnet mask Gateway User name This can be either admin or user Password The factory configured passwords for all accounts on this device have been set to the device serial number Passwords are case sensitive NOTE If the device is reset to default settings the password will be the default password configuration The default password is extron for either admin or user MAC addre...

Страница 20: ...tactiles ou les processeurs de contrôle avant d avoir lu la mise en garde sur les sources d alimentation via Ethernet PoE voir page 7 Once the touchpanel is set up for network communication disconnect the Ethernet cable before installing modules and mounting the enclosure 7 Prepare and install modules in the touchpanel enclosure see Preparing MAAP or AAP Modules on page 17 Preparing Cable Pass thr...

Страница 21: ...stallation The location of devices that connect to the AAPs either above or below the table 2 Verify that you have the correct template or dimensions see Cut out Dimensions on page 15 3 Decide on the method for cutting a hole in the table see Cutting the Surface on page 15 There are three methods available Hand router and guide see page 16 requires a router template which must be purchased separat...

Страница 22: ...ug 4 1 4 Hole Plug 1 6 32 Screw 4 6 Star Washer 4 TLP Pro 525C or TLP Pro 525C NC 1 2 space MAAP Frame 1 TLP Pro 525C Connectivity Bracket 1 Short Clevis Pin 1 Cotter Pin 1 HDMI Lockit 1 Tie wrap 1 5 cable Pass through Plate 1 Figure 6 Parts Included with the TLP Pro 525C or TLP Pro 525C NC TLP Pro 725C TLP Pro 725C or TLP Pro 725C NC 1 4 40 Screw 8 6 32 Screw 8 6 Star Washer 8 3 8 Hole Plug 12 1 ...

Страница 23: ...ntal mounting difficult To satisfy ADA compliance requirements for XL models there is also an option to mount the retractors at a 30 angle see the Retractors User Guide which is available at www extron com Retractor Clearance for the TLP Pro 525C Series 14 97 380 mm 5 27 134 mm 9 69 246 mm 17 04 433 mm 1 64 42 mm 23 64 600 mm Standard Models Retractor Mounting Clearance XL Models 20 97 533 mm 23 0...

Страница 24: ...2 mm 23 6 599 mm 21 00 533 mm 1 60 41 mm 29 6 752 mm 23 00 584 mm Retractor Mounting Clearance Standard Models XL Models 15 00 381 mm Figure 9 Under table Retractor Clearance Requirements for the TLP Pro 725C Series TLP Pro 525C and 725C Series Touchpanels Mounting 14 ...

Страница 25: ... to the surface cutout dimensions before cutting a hole in the furniture or other surface Pay special attention to the direction the unit will face The connector access side is underlined see CNC wood router on the next page Extron is not responsible for miscut mounting holes Utilisez le gabarit de détourage métallique approprié ou reportez vous aux dimensions de découpe de la surface indiquées ci...

Страница 26: ...h ec k th e pr int se tti ng s be fo re pr int ing an d ma ke su re th e pa ge is no t sc ale d 3 Re mo ve th e su rfa ce cu t o ut ar ea g ra y fro m th e tem pla te by cu tti ng alo ng th e re d lin e DO NO T CU T th e gr ay do tte d lin es 4 Me as ur e th e cu to ut an d tem pla te Ma ke su re th e dim en sio ns ar e th e sa me as th os e sh ow n 5 Pl ac e th e tem pla te an d ma rk th e po sit...

Страница 27: ... the connectivity bracket 3 4 Secure the MAAP frame to the connectivity bracket using the captive screw 4 that is provided with the MAAP frame 5 Insert the assembled MAAP module into the touchpanel enclosure see Installing Modules on page 19 U S B H U B 4 M A A P AC TI VI TY Mini Type B USB Extron USB HUB4 MAAP USB Hub 4 4 40 Screws 1 1 1 2 2 2 3 3 3 4 4 4 Figure 12 Assembling a MAAP Module Assemb...

Страница 28: ...ur tabs of the grommet plate into the four holes of the connectivity bracket 2 5 Secure the grommet plate to the connectivity bracket using the captive screw 3 that is provided with the grommet plate 6 Insert the assembled cable pass through module into the touchpanel enclosure see Installing Modules on page 19 e 2 1 9 1 8 1 2 3 Figure 14 Assembling the 525C Cable Pass through Module Assembling th...

Страница 29: ...chased separately See the Extron website www extron com to select a power module that is suitable for your location Retractor Triple Bracket accommodating up to three retractors Series 2 Connectivity Brackets accommodating up to three AAPs or eight pass through cables Cable Quad Brackets accommodating up to four pass through cables TLP Pro 525C The 525C modules must be installed at the ends of the...

Страница 30: ...he cotter pin NOTE Use a similar procedure to mount up to three retractors into a Retractor triple bracket module e 21 525 01 LF 21 525 01 LF 21 52 6 0 1L F 21 52 6 0 1L F Insert Retractors into the bracket Slide the bracket into the enclosure as shown either side 1 3 4 Secure the bracket with the included screws and washers 2 Secure the Retractors with the included mounting pin and clip Secure th...

Страница 31: ... ATTENTION Risque de décharge électrique Afin d assurer une mise à la terre correcte utilisez les fixations de mise à la terre et les rondelles en étoile fournies 1 Slide the module into the enclosure from underneath 1 Ensure the mounting holes on the module are aligned with the holes on the front of the enclosure 2 Secure the module with the provided 6 32 screws and 6 star washers 2 e 21 525 01 L...

Страница 32: ... to install an AC power module The Retractor bracket module and Series 2 Connectivity bracket modules are installed in the same way Install the modules as follows 1 Insert the module into the cable cubby see figure 19 1 Make sure the mounting holes on the module line up with the holes on the enclosure Mount retractors in the far left or far right end spaces at the lowest height inside the touchpan...

Страница 33: ...alimentation est installé à côté des rétracteurs assurez vous qu il ne puisse pas s emmêler dans le mécanisme du rétracteur de câbles ATTENTION All structural steps and electrical installation must be performed by qualified personnel in accordance with local and national building codes and electrical codes Toute étape structurelle et installation électrique doit être effectuée par un personnel qua...

Страница 34: ... 21 5 25 0 1L F 21 5 25 0 1L F 21 5 26 0 1L F 21 5 26 0 1L F Rotate the clamp outward and ensure that the lever is down Slide the clamp all the way up against the bottom of the table Ensure the TLP Pro 725C is firmly seated in the table Rotate the lever up to secure the enclosure 2 1 3 Lever Figure 20 Mounting the TLP Pro 725C Enclosure Locking Plate NOTE To lower the side clamp turn the lever dow...

Страница 35: ... with the included mounting pin and clip Secure the locking screw on each Retractor Do not overtighten 5 Figure 21 Installing Cable Retractors Extron recommends mounting an empty Retractor bracket into the touchpanel and installing the retractors after the enclosure is seated in the table 1 Slide the Retractor bracket into the enclosure see figure 21 1 2 Secure the bracket to the enclosure with th...

Страница 36: ...is very similar Press the Status button in the navigation panel at the top of any screen to open the Status screen Status Display Audio Advanced Exit Network Info Model TLP Pro 725C Part Number 60 1564 02 Firmware Version 1 02 0001 b001 Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Display Resolution GUI Project Sleep Timer 1024x600 N A 5 Minutes Audio Master Volume Master Mut...

Страница 37: ...f IP addresses are assigned by DHCP press On If the IP address is to be assigned manually press Off When DHCP is off the Host Name is grayed out and cannot be edited All addresses can be edited as shown in figure 23 When DHCP is on the Host Name can be edited The addresses are grayed out and cannot be edited because they are set by the DHCP server If IP addresses are assigned manually press Off 2 ...

Страница 38: ...o enter the 89 but the 2 cannot be entered When a valid 3 digit value is entered the next octet is automatically selected c Press OK to save the changes and return to the Network screen or press Cancel to return to the Network screen without saving the changes 4 If you have changed any of the values in the Network screen the background color of the button changes to blue Press Apply to apply the n...

Страница 39: ...anel does not enter sleep mode Auto Brightness Toggle between On and Off If Auto Brightness is on the light sensor see figure 2 D on page 6 monitors the amount of ambient light detected and automatically provides a suitable amount of screen backlighting for the situation If Auto Brightness is off the screen brightness is not affected by changes in the ambient light LCD Brightness Use the slider co...

Страница 40: ...ttings Master Sets the maximum volume for all the other sound volume settings For example if the master volume is set to 80 80 percent of maximum even when the sound volume is set to 100 it is equivalent to only 80 percent of maximum Click Sets the volume for audible feedback that accompanies events such as a screen button being pressed Sound Sets the volume of audio from any audio file playback C...

Страница 41: ...ing information about the system the Global Configurator Project and the GUI Designer Project Menu PIN The PIN setup options allow you to enable disable or change the setup menu PIN The PIN is a 4 digit number Each digit can have any value from 0 9 1 Enter a four digit PIN Enter New Menu PIN 4 5 6 7 8 9 0 2 1 3 Cancel Back Figure 30 Numeric Keypad for Setting PIN 2 The title bar changes to Confirm...

Страница 42: ...ayout of the screen text and graphics using GUI Designer You can either customize an existing template or create an entirely new interface GUI Designer offers several templates 2 After designing the user interface the project is saved built and imported into Global Configurator where the appropriate control functions are assigned to the text and graphic items of the interface After assigning the c...

Страница 43: ... Configurator Toolbelt and Global Scripter can be downloaded from www extron com 1 Select the Download button see figure 31 1 and then click the Software option 2 1 1 1 2 2 2 Figure 31 Extron Download Page You may see the product immediately for example Global Configurator Plus and Professional see figure 32 2 Use the left and right arrows 3 to scroll through all the highlighted products If the so...

Страница 44: ...d follow the on screen instructions 3 Run the executable file to install the software By default your computer creates a new folder at C Program Files Extron or C Program Files x86 Extron Using the Software GUI Designer Use the GUI Designer software to design the screen layout for the touchpanel see the GUI Designer Help file for step by step instructions and more detailed information Global Confi...

Страница 45: ... the web browser of a PC connected to the same subnet A dialog box opens asking for your user name and password NOTE The factory configured passwords for all accounts on this device have been set to the device serial number If the device is reset the password reverts to extron Passwords are case sensitive Figure 33 shows the TLP Pro 725C web page The web pages for the TLP Pro 525C very similar Fig...

Страница 46: ...er T from the alphabet menu 4 Scroll down the page until you find the firmware for your TLP Pro model Figure 35 TLP Pro Firmware download 5 Click Release Notes see figure 19 1 for more information about the firmware optional 6 Click Download 2 7 Enter the required information and click the download button An executable exe file is downloaded to your computer Run this program to place the firmware ...

Страница 47: ... single power cycle in the event of a firmware update that failed or incompatibility issues arising with user loaded firmware Activation To start the Use Factory Firmware reset mode and replace firmware 1 Remove power from the touchpanel 2 On the touchpanel hold down the recessed Reset button B while re applying power to the unit When power is restored the Reset LED C lights Hold the Reset button ...

Страница 48: ...efaults and removes all configurations It allows you to start over with configuration and uploading NOTE The factory configured passwords for all accounts on this device have been set to the device serial number If the device is reset to factory defaults the passwords revert to extron Passwords are case sensitive Activation To reset the unit to all factory default settings 1 Hold down the Reset bu...

Страница 49: ...controller NOTES You must run Toolbelt as an administrator Some certificates require a passphrase that is created when the certificate is created If a passphrase is required you must enter that passphrase before uploading and applying the certificate These devices support standard OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file t...

Страница 50: ...cation for the TouchLink Pro control systems DER Distinguished Encoding Rules file types are binary encoded and can typically have several file extension variations such as crt and cer NOTE DER encoded files files with der crt or cer extensions that are encoded in DER binary format must be converted to a PEM encoded file type pem before being used for authentication DER encoded certificates must b...

Страница 51: ...arranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 ...

Отзывы: