background image

 

2

TLP Pro 1220, 1520, and 1720TG • Setup Guide (cont’d)

Mounting

A range of optional mounting kits are available for all three models. The 
kits must be purchased separately. Follow the installation instructions 
provided with the kit.

Removing the back and base covers

Some of these procedures require the back and base covers to be 
removed. You must remove the back cover before you can remove the 
base cover.

1. 

Use the provided Extron removal tool. There is one notch on each 
side of the back cover (figure 1, 

1

). Insert the tool into the notch to 

release the catch.

2. 

Use the removal tool to remove the base cover. There are two 
notches at the back of the base (

2

).

2. 

Drill two pilot holes into the desktop.

3. 

Remove the base cover (see Removing the Back and Base 
Covers, above).

4. 

Insert two #10 flat-head wood screws (not provided) through 
the touchpanel and align them with the two pilot holes.

5. 

Secure the touchpanel to the tabletop.

6. 

Replace the base cover.

Kensington

®

 Security Lock

For added security, attach a Kensington Security Lock 
(not provided) to the metal-reinforced Kensington Security 
Slot on the rear edge of the base (figure 3, 

1

). The figure 

shows the rear edge of the TLP Pro 1520TG base, but the 
bases of the TLP Pro 1220TG and TLP Pro 1720TG are 
very similar. Follow the instructions that are provided by the 
manufacturer to install the lock.

Desktop Mounting

The TLP Pro 1220TG, TLP Pro 1520TG, and TLP Pro 1720TG 
come assembled with stands that allow the units to be placed on 
any suitable flat surface (for example a desk, table, or lectern).

Fixed Mounting

Figure 2 shows the base of the TLP Pro 1220TG, with the cover 
removed to indicate the position of the mounting holes. The bases 
of the TLP Pro 1520 TG and TLP Pro 1720TG are similar and the 
spacing of the mounting holes (figure 2, 

1

) is identical.

1. 

Mark the location for two holes, 4.96 inches (126 mm) apart. 
This measurement is the same for all three models.

1

1

1

SMA-1 Swivel Mount Adapter

To swivel either device up to 180° in either direction, use the optional Extron SMA-1 swivel mount adapter, to permanently mount the 
touchpanels.

1. 

Remove the back cover and base cover (see 

Removing the back and base covers

, above).

2. 

Attach the conduit, insulation disk, and swivel disk and configure the set screws to allow for the degree of swivel that is required 
(see the 

SMA-1 Swivel Mount Adapter Kit User Guide

, available at 

www.extron.com

).Place the mounting hole in the base over 

the conduit of the SMA-1.

3. 

Secure the unit with the backing plate and locking nut as described in the 

SMA-1 Swivel Mount Adapter Kit User Guide

.

VESA Mounting

Use a third-party D-type VESA mounting kit with the 100 mm x 100 mm mounting pattern.

1. 

Remove the back cover.

2. 

Remove the four screws holding the touchpanel to the base. There are two screws in each base attachment hinge 
(

figure 5

K

 on page 4).

3. 

Follow the instructions provided with the VESA mounting kit.

1

1

1

Figure 1. 

Remove the Back and Base Covers

figure 1

Figure 2. 

Mounting Holes in TLP Pro 1220TG Base

Figure 3. 

Slot for Kensington Security Lock

figure 3

1

1

1

2

2

2

2

2

2

1

1

1

Содержание TouchLink TLP Pro 1220 Series

Страница 1: ...words The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive NOTE If the device is reset to default settings the passwords are reset to the default password which is extron for either admin or user Make a note of the touchpanel MAC address Mount and Cable All Devices ATTEN...

Страница 2: ...ed with stands that allow the units to be placed on any suitable flat surface for example a desk table or lectern Fixed Mounting Figure 2 shows the base of the TLP Pro 1220TG with the cover removed to indicate the position of the mounting holes The bases of the TLP Pro 1520 TG and TLP Pro 1720TG are similar and the spacing of the mounting holes figure 2 1 is identical 1 Mark the location for two h...

Страница 3: ...e enabled and disabled using the Setup Menu see page 6 B Status light can be programmed to provide system feedback The LED light bar is located above the screen C Ambient light sensor monitors ambient light level and adjusts screen brightness D Capacitive touch screen provides simple control of AV systems The TLP Pro 1220TG has a 12 1 inch screen with a 1280x800 resolution The TLP Pro 1520TG has a...

Страница 4: ... your XTP product LAN input Connect the touchpanel to the LAN using a twisted pair cable terminated with an RJ 45 connector PoE input the connector can be used with a PoE power injector Connect the cables as shown in figure 6 which shows the Extron PI 140 power injector recommended by Extron NOTE Some XTP models are able to remotely power these touchpanels but not all have that capability Go to th...

Страница 5: ...y press the Reset button Use this mode to return the interface to factory default settings NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive If the device is reset to default settings the passwords are reset to the default password which is extron for either adm...

Страница 6: ... Audio Input and Advanced by pressing the appropriate button in the navigation bar at the top of the screen for more information see the TLP Pro 1220 TLP Pro 1520 and TLP Pro 1720 Series User Guide Figure 7 shows the setup menu for the TLP Pro 1220TG The setup menus for the TLP Pro 1520TG and TLP Pro 1720TG are very similar Press the Menu button for at least 3 seconds to open the calibration scree...

Отзывы: