This guide provides quick start instructions for an experienced installer
to set up and operate the SW RGBHV and SW RGBHV A
switchers.
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources
and mount the switcher as required.
Step 2 — Inputs
• Connect up to 2, 4 or 6 RGBHV, RGBS,
RGsB, or RsGsBs video or component
video inputs to the Input connectors.
•
Audio models —
Connect up to 2,
4 or 6 stereo or mono audio inputs
to the 5-pin
captive screw
connectors.
Step 3 — Outputs
•
Connect an RGBHV, RGBS, RGsB, or RsGsBs video or component video display or
other device to the Output connectors. Make connections as shown for step
3
.
•
Audio models —
Connect a balanced or unbalanced stereo audio or mono audio
device to the 5-pin captive screw connector.
C
Connect the sleeves to ground (Gnd). Connecting the sleeve to a negative (-) terminal
will damage the audio output circuits.
Step 4 — Remote port
Connect a host device, such as a computer or touch
panel control via RS-232,
OR
connect a remote contact
closure device to the switcher
via the 9-pin D connector for
remote control of the switcher.
To command a switch under
contact closure control,
momentarily short an input’s
pin on the remote connector to
ground (the switcher must be in
normal [manual] mode).
N
For complete descriptions of remote control of the switcher using the applicable Simple
Instruction Set (SIS
™
) commands and/or the Universal Switcher Control Program, refer to
the full
SW RGBHV Switchers User’s Manual
, available at
www.extron.com
.
Step 5
— Power
Plug a standard IEC power cord between the switcher’s power connector and a 100 VAC to
240 VAC, 50 or 60 Hz power source.
Operation
Switch mode
Set the rear panel switch to Auto for autoswitch mode (the switcher automatically
switches to the highest-numbered input with a sync signal present) or Normal for
manual switch mode. The front panel Auto Switch Active LED lights when the
switcher is in autoswitch mode.
Switch inputs in normal switch mode
Press and release the desired input button.
Adjust audio level (audio models)
You can set the input level of audio gain or attenuation via the front panel or the Remote port
to be compatible with a wide range of line level sources. Individual input audio levels can be
adjusted so that there is no noticeable volume difference among sources. This function also
eliminates the need for separate preamps or attenuators, when used with professional (higher
line level) and consumer (lower line level) audio equipment.
Adjust the audio from the front panel as follows:
1
. Pre
ss and release the desired input button.
2
. Press and hold the Audio Conf./Save button until the Audio Conf./
Save LED begins to blink. The approximate level is indicated by the
input LEDs and the polarity by the ±dB LEDs.
N
The input LEDs display the approximate level of attenuation.
The +dB LED indicates the level is gain (positive).
The - dB LED indicates the level is attenuation (negative).
For details about reading the displayed value, refer to the
full
SW RGBHV Switchers User’s Manual
, available at
www.extron.com
.
3
. Press and release the
>
and
<
buttons to increase and decrease the audio level by 1 dB
per push of the button, or press and hold the buttons to increase or decrease the level
by 3 dB per second.
4
. Press and release the Audio Conf./Save button to exit. The Audio
Conf./Save LED goes out.
Do not tin the wires!
Unbalanced Stereo Output
Balanced Stereo Output
Ring
Sleeve(s)
Tip
Tip
Ring
Sleeve(s)
Tip
Tip
NO GROUND HERE.
NO GROUND HERE.
L
R
L
R
Unbalanced Stereo Input
Balanced Stereo Input
L
R
L
R
Ring
Sleeve (s)
Tip
Sleeve
Tip
Sleeve
Tip
Tip
Ring
Do not tin the wires!
Setup Guide — SW RGBHV Series Switchers
Extron
USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517
FAX
Extron
USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797
FAX
Extron
Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050
FAX
Extron
Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664
FAX
Extron
Japan
+81.3.3511.7655
+81.3.3511.7656
FAX
Extron
China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566
FAX
Extron
Middle East
+971.4.2991800
+971.4.2991880
FAX
© 2009 Extron Electronics. All rights reserved.
68-648-50
Rev. A
04 09
Setup Guide — SW RGBHV Series Switchers
CONF/SAVE
B
Press
and
hold.
Conf/Save blinks.
Release the button.
2
6
5
4
3
2
1
-dB +dB
3
Press
Press
CONF/SAVE
Press
and release.
4
G
RGBHV
RGBS
RGsB,
RsGsBs,
Component
B
H
/HV
V
R
G
B
H/
HV
V
R
G
B
H/HV
V
Pin RS-232 Contact
closure
Function
1
—
In #1
Input #1
2
TX
—
—
Transmit data (-)
3
RX
Receive data (+)
4
—
In #2
Input #2
5
Gnd
RS-232 Protocol:
9600 Baud, 8, N, 1
Gnd
Signal ground
6
—
In #3
In #4
In #5
In #6
Input #3
Input #6
Input #4
Input #5
7
—
8
—
—
Female
5
1
9
6
AUTO
MANUAL
1
Press
and release.
1