SMX System MultiMatrix Switchers
• Configuration and Control
5-3
Starting the program
1.
Click
Start
>
Programs
>
Extron Electronics
>
SMX
Control Program
>
SMX Control Pgm
icon.
The Comm Port Selection window appears.
2
.
Choose the comm (serial) port that is connected to the
switcher or
IP [LAN]
.
N
For a comm port
, check the baud rate displayed in the
comm port selection window. To change the baud rate,
click the
Baud
button, double-click the desired baud rate.
Click
OK
.
If you selected a comm port in step 2
, the SMX Control
Program is ready for operation.
3
.
If you selected IP [LAN] in step 2
, the IP Connection
window appears.
a
. Examine the Matrix IP Address field, which displays
the last Matrix IP address entered and a drop down box
with a list of the most recently used IP addresses.
If listed, select the applicable IP address, or enter the
correct IP address in the field.
N
192.168.254.254 is the factory-specified default IP address.
b
. If the switcher is password protected, enter the
appropriate administrator or user password in the
Password field.
c
. Click
Connect
. The SMX Control Program is ready for
operation.
Also refer to the
SMX System MultiMatrix Switchers User’s Manual
at www.extron.com.