Front Panel Overview

SME 100

STREAMING MEDIA ENCODER

ADJUST

1

MENU

NEXT

2

3

1

2

3

4

5

6

CONFIG

a

 

Config port

 — Connect a control PC to this port using a Mini-B USB cable (not supplied). Use this port to send  

SIS commands to the SME 100 for device configuration and control.

NOTE:

  For information on using this port for device configuration and control and for a list of available  

SIS commands, see the 

SME 100 User Guide

.

b

 

Input selection buttons

 — These buttons select and switch inputs. A green LED lights to indicate the selected input. A 

blinking LED indicates an audio breakaway input. An input that does not contain an input source can still be selected, 
but the LCD display will show 

No Signal

.

 

z

Button 1 selects input 1 (component video, S-video, or composite video).

 

z

Button 2 selects input 2 (component video, S-video, composite video, and RGB video [RGBHV, RGBS, RGsB, RGcvS]).

 

z

Button 3 selects input 3 (DVI-D video).

c

 

Menu button

 — Pressing this button navigates through the primary configuration menus of the SME 100.

d

 

Next button

 — Pressing this button navigates through the configuration submenus of each primary menu.

e

 

LCD display

 — This display shows the device settings and menu configuration information.

f

 

Adjust knobs

 — These are used with the Menu and Next buttons to adjust the settings of the configuration menus.

About the Front Panel Lock (Executive Mode)

The front panel buttons on the SME 100 can be locked so that configuration cannot be made using the front panel. The 
following modes are available.

 

z

Exe Mode Disabled

 (default setting) — Front panel lock is disabled. The front panel can be used to configure the unit.

 

z

Exe Mode Enabled

 — Front panel lock is enabled. The front panel 

cannot

 be used to configure the unit. The SME 100 

can only be configured with a connected control system or PC.

Enabling or disabling front panel lock using the front panel

To enable or disable front panel lock, press and hold the Menu and Next buttons simultaneously for approximately two 
seconds. The LCD display indicates (for approximately two seconds) that the front panel lock is either enabled or disabled, 
then returns to the default display cycle. When front panel lock is enabled on the SME 100 and a front panel action is 
attempted, the LCD display shows 

Exe Mode Enabled

 for approximately two seconds.

Configuring the Network Settings of the SME 100 Using the Front Panel

The SME 100 contains eight primary configuration menus and one hidden menu that are available on the front panel  
LCD display. In order to access the web-based user interface of the SME 100, the network settings may need to be 
configured. The SME 100 is pre-configured with the following network settings:

IP address:

 

 

  192.168.254.254 

Subnet mask:

  

 

255.255.0.0 

Gateway address:

  

0.0.0.0

NOTE:

  With these settings, the control PC and viewing devices must use IP addresses within the range of 192.168.0.1 

through 192.168.254.253 and use the same subnet mask.

Use the following procedure to configure the network settings of the SME 100, if necessary.

Menu

PRESETS

INPUT

CONFIG

PICTURE

CONTROL

OUTPUT

CONFIG

AUDIO

CONFIG

ADVANCED

CONFIG

VIEW COMM

SETTINGS

EDIT COMM

SETTINGS

Menu

Menu

Menu

Menu

Menu

Input 3

EXIT MENU?

PRESS NEXT

Menu

+

Next

Menu

1. 

Press the Menu button repeatedly until the View Comm Settings menu is shown on the LCD display.

2. 

Press and hold the Next button and the Input 3 button simultaneously for approximately three seconds. This changes 
the View Comm Settings menu to the Edit Comm Settings menu.