Installing the Speaker System in a Hard Ceiling
If you are installing the SF 3C LP or SF 3CT LP in a hard ceiling (having no ceiling tiles), with
the ceiling structure in place, follow the steps below:
1.
Disconnect power
—
Power down all attached devices before proceeding.
2.
Cut a hole for the speaker
—
Use the provided cutout template to outline the hole to
be cut in the ceiling as described below.
a.
Mark the location on the ceiling where the center of the speaker will be placed.
b.
Position the center hole of the cutout template directly over the center mark.
c.
Trace a circle around the cutout template.
d.
Cut out the traced circle.
3.
Fold one C-ring assembly in half and insert it through the hole in the ceiling.
4.
Unfold the C-ring and center it over the hole with the flat side down.
Figure 33.
Installing the C-ring
5.
Route the speaker wires
through the ceiling hole.
SF 3C LP and SF 3CT LP User Guide • Installation