SF 10C SUB • Installation
17
NOTE:
The cable conduit access plate has an alternate hole that is available by
removing the knockout.
Cable
Clamp
1
— OR —
2
3
Flexible
Conduit
Adapter
3
3
3
Figure 11.
Connection Using a Cable Clamp or Flexible Conduit
3.
Strip 3/16 inch (5 mm) of the cable insulation from the wire ends.
NOTES:
•
The length of exposed wires is important. The ideal length is 3/16 inch (5 mm).
•
If the stripped section of wire is longer than 3/16 inch, the exposed wires
may touch, causing a short circuit.
•
If the stripped section of wire is shorter than 3/16 inch, wires can be easily
pulled out even if tightly fastened by the captive screws.
•
Do not tin the leads before installing them in the connector. Tinned wires are
not as secure in the connector and could be pulled out.
11