Extron electronics RGB 400xi Series Скачать руководство пользователя страница 5

RGB 400

xi

xi

xi

xi

xi

 Series Installation Guide

RGB 400

xi

xi

xi

xi

xi

 Series Installation Guide

Installation, cont’d

2

To prevent short circuits, the outer foil shield can be
cut back to the point where the cable exits the cable
clamp.  Both braided and foil shields should be
connected to an equipment ground at the other end
of the cable.

7.

Insert the MK box into the opening, and secure it to the
wall stud or furniture with nails or screws, leaving the
front edge flush with the outer wall or furniture surface
(figure 2).

Installation

Cable

Screws or
Nails

Wall Stud

Flush with

Outside Wall

Figure 2 — Securing the MK knockout box to a
wall or furniture

8.

Set the gain and DIP switches and cable and test the
interface before securing the interface into the wall box.

The switches and cables will be inaccessible after
installation

.  Refer to the specific user’s manual for your

interface.

Mounting the interface MK to the knockout box

1.

Disconnect the power supply to remove power from the
interface.

2.

Place the interface through the opening in the wall or
furniture and into the knockout box.  Take care not to
damage the cables, which will lay next to the interface at
the side of the box.

3

Installation Instructions

The MK box is not included with the interface; the
installer is responsible for obtaining and installing the
box.

The MK box must have a minimum depth of 47 mm.

Preparing the site and installing the MK box

Choose a location that allows cable runs without interference.
Allow enough depth for both the MK box and the cables.  You
may need to install the cables into the wall, furniture, or
conduits before installing the interface.

The installation must conform to national and local electrical
codes and to the interface’s size requirements.  Dimensional
drawings and actual-size cut-out templates are provided at the
end of this guide.

1.

Cut out the center portion of the cut-out template.

2.

Place the template (or the MK box) against the installation
surface, and mark the guidelines for the opening on the
wall or furniture.

3.

Cut out the material from the marked area.

4.

Check the opening size by inserting the MK box.  The box
and interface should fit easily into the opening.  Enlarge or
smooth the edges of the opening if needed.

5.

Feed cables through the wall box punch-out holes, and
secure them with cable clamps to provide strain relief.

6.

Exposed cable shields (braids or foil) are potential sources
of short circuits.  Trim back and/or insulate shields with
heat shrink (figure 1).

Installation Cable

Metal Wall Box

Screw

Braided Shield

Figure 1 — Grounding outer braided and foil shields

Содержание RGB 400xi Series

Страница 1: ...Installation Guide MK Box Mounted Interface 68 636 02 Rev B Printed in the USA 09 02 RGB 400xi xi xi xi xi Series Installation Guide...

Страница 2: ...sam machen da im Inneren des Geh uses dieses Produktesgef hrlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie...

Страница 3: ...ut box 3 Specifications 4 Included Parts 5 Accessories 6 Audio connector 6 Accessories 6 Cables 6 Male to male VGA cables 6 Male to male 90 VGA cables 6 Laptop breakout cables 6 High resolution cables...

Страница 4: ...nel only This product must be used with the correct MK electrical box Install the interface as follows 1 Turn all of the equipment off Make sure that the computer the interface and the output devices...

Страница 5: ...ation Instructions The MK box is not included with the interface the installer is responsible for obtaining and installing the box The MK box must have a minimum depth of 47 mm Preparing the site and...

Страница 6: ...0 000 hours Warranty 3 years parts and labor Specifications are subject to change without notice Included Parts These items are included in each order for an RGB 460xi or RGB 472xi MK interface Includ...

Страница 7: ...Accessories Audio connector Part number 3 5 mm stereo plug 10 306 01 MK mounting bracket black white unfinished 70 086 16 26 56 Accessories Part number Mac VGA adapter VGA male Mac female Mac RGBS 1 2...

Страница 8: ...2 765 2 190 1 690 1 490 1 270 770 615 000 000 10 2 PLCS DETAIL A 0 125 THRU C BORE 0 250 x 0 50 DEEP 2 PLCS R 0 132 TYP 0 984 0 806 0 224 0 449 SECTION A A A A Figure 4 RGB 460xi xi xi xi xi MK Dimens...

Страница 9: ...2 68 H x 5 25 W for the installation surface The inside solid line 3 38 H x 5 70 W represents the outside edge of the RGB 460xi wall plate Template for the MK mounting bracket The outside solid line 3...

Страница 10: ...sed by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is def...

Страница 11: ...The Netherlands 31 33 453 4040 Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan...

Отзывы: