background image

RGB 324/326/340 • Installation and Operation

RGB 324/326/340 • Installation and Operation

Installation and Operation, cont’d

2-10

2-11

Metal Wall Box

Screw

Braided Shield

Installation Cable

Foil Shield

Cable Clamp

To prevent short circuits, the outer foil sheild can be
cut back to the point where the cable exits the cable
clamp.  Trim back or use heat shrink to insulate all
shields (braided or foil) from the circuit board.  If
shields contact the circuit board, a short circuit may
occur.  Also, both the braided and foil sheilds should
be connected to an equipment ground at the other
end of the cable.

Connecting the buffer to the RGB 320
with installation cable

The cabling examples on page 2-14 and 2-15 show a buffer
wired for RGBHV video and balanced audio output using
seventeen conductor plenum installation cable.

Extron recommends using Extron’s seventeen conductor bulk
plenum installation cable (part numbers 22-111-03, 22-111-04) or
equivalent.  Installation cable includes coaxial cables for video
signals, shielded twisted pair wires for audio, and single
conductors for power and communications signals.

Connect the cables between the buffer and the
RGB 320 interface on a one-to-one basis.  Cable
conductor assignments must be the same at both
ends of the cable

, or damage may occur to circuits

in the buffer and/or the RGB 320.

Remove power from both the buffer and the
RGB 320 while cables are being attached.

Preparing and terminating the cable

Use the illustrations on pages 2-14 and 2-15 as wiring guides.
They show connectors and conductor assignments for the buffers
and the RGB 320.

1.

Select and install a multiconductor cable, such as the
Extron Plenum seventeen conductor installation cable, which
contains appropriate conductors (at least 5 coaxial, 3 sets
of shielded twisted pair, 3 single 20 AWG) for the video,
power, control, and audio signals that this system will use.

4.

Remove the Adjust knob.  You may need a very small
diameter Allen wrench to loosen the nut that holds it in
place.

5.

Slide the top part of the enclosure slightly forward, then
upward to remove the cover.  The circuit board remains in
the bottom portion of the enclosure.

H-SHIFT

HIGH-Z

INPUTS

ANALOG

AUDIO

SHOW ME/

SELECT

V-SHIFT

VIDEO LEVEL

AUDIO LEVEL ADJUST

Remove (5)
Screws

Remove (2)

Connector Nuts

and Knob

Opening the RGB 340 enclosure

6.

Set the level/peaking jumpers.  See the jumper diagram on
page 2-9.

7.

Reverse steps 2 through 5 to replace the cover.

Cabling

All the output, power, and control  cables from the RGB 324,
RGB 326, and RGB 340 buffers go directly to the RGB 320
switching interface.  Refer to the RGB 320 User’s Manual  and see
“Connecting the buffer to the RGB 320 with installation cable”
in this chapter when making and connecting cables for the
buffers.  Run the cables through the wall/furniture and into the
electrical box (if used) before attaching connectors.

Input connections

Input connections and audio input connector wiring are
discussed on page 2-5.

Connecting shields

Multiconductor cables contain several braided and foil shields.
At the buffer end of the cable, the outer braided and foil shields
should be connected to the grounded metal wall box (or to a
grounding wire if a metal wall box is not used).  The wires that
make up the braided shield can be unbraided, then twisted
together to form a large, multi-strand wire that can be folded
back under the wall box cable clamp or attached to the metal
wall box with a screw.  See the following illustration.

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание RGB 324

Страница 1: ...sia 135 Joo Seng Rd 04 01 PM Industrial Bldg 65 383 4400 FAX 65 383 4664 Singapore 368363 Extron Electronics Information ExtronWEB www extron com ExtronFAX 714 491 0192 24 hour access worldwide 2000 E...

Страница 2: ...k nnen Wartung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schoc...

Страница 3: ...nt 2 9 Cabling 2 10 Input connections 2 10 Connecting shields 2 10 Connecting the buffer to the RGB 320 with installation cable 2 11 Preparing and terminating the cable 2 11 Pre installation testing t...

Страница 4: ...nt d RGB 324 326 340 1 Chapter One Introduction About the RGB 324 RGB 326 and RGB 340 Interface Buffers Features 68 338 01 E Printed in the USA 09 00 im Vertrieb von CAMBOARD Electronics www camboard...

Страница 5: ...defined picture control settings that are specific to the installation so it is not necessary to make adjustments each time an input is selected Furniture and wall mountability The RGB 324 and RGB 326...

Страница 6: ...on cont d RGB 324 326 340 2 Chapter Two Installation and Operation Installation Overview Installation and Operation Instructions 1 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 9112...

Страница 7: ...ng the site installing the wall box RGB 324 RGB 326 When selecting an installation site choose a location that will allow cable runs without interference preferably next to a 2 x 4 wall stud or a stru...

Страница 8: ...e cables to the rear panel The jumpers and cables will be inaccessible after installation See Rear panel circuit board features and jumpers and Cabling in this chapter for details 5 Align the screws w...

Страница 9: ...ess the Show Me Select button again or wait 7 5 seconds to exit the adjustment mode When an adjustment reaches a minimum or maximum limit the buffer s adjustment indicator 7 LED blinks The RGB 320 s L...

Страница 10: ...Level peaking jumpers Changes to video peaking may be needed for high resolution signals or to compensate for signal loss from long cable runs The buffers have separate jumpers for red green and blue...

Страница 11: ...r installation cable which contains appropriate conductors at least 5 coaxial 3 sets of shielded twisted pair 3 single 20 AWG for the video power control and audio signals that this system will use 4...

Страница 12: ...DIO Connect the sleeve to ground Connecting the sleeve to a negative terminal will damage the audio output circuits Insert the tips of the white black twisted pair wires into the captive screw connect...

Страница 13: ...COM PWR Anaheim CA A B C D E COM PWR A B C D E White Black Shields Red Black Black Orange Brown Violet Grey White Black Shields Red Black Black Orange Brown Violet Grey 2 1 R L R L RGB 320 Rear Panel...

Страница 14: ...button on the buffer If the Show Me Select button blinks the RGB 320 is busy and the Show Me Select button must be pressed a second time 5 Call the Extron S3 hotline if the image still does not appear...

Страница 15: ...O RGB 326 Mounting the buffer to the wall box 5 Reconnect the input cables to the buffer s front panel connectors 6 Reconnect the power cables and restore power to the equipment Application diagram La...

Страница 16: ...3 1 kHz 0 3 20 kHz at rated maximum output drive S N 90dB output 17dBu balanced Stereo channel separation 95dB 1 kHz to 20 kHz Audio input buffered to RGB 320 Number signal type 1 stereo unbalanced 1...

Страница 17: ...ries Part number RGB 320 switching interface 60 232 01 3 5 mm stereo plug 10 306 01 Cables Bulk installation cable Part number Plenum seventeen conductor installation cable 500 feet 152 meters 22 111...

Страница 18: ...060 DEPTH C BORE ON THE NEAR SIDE 2 PLCS 160 THRU WITH C SINK 290 x 82 ON NEAR SIDE 4 PLCS CODED A 166 THRU TYP 6 PLACES CODED C 136 THRU TYP 2 PLCS CODED B PEM STANDOFF BSOS 440 22 NOTE DRAWING NOT T...

Страница 19: ...ng the installation DETAIL A DETAIL B DETAIL C DETAIL D ROTATED 180 DETAIL C 4 PLACES R 132 4 CORNERS 2 PLCS DETAIL D DETAIL B DETAIL A 125 THRU CODED a 6 PLCS 503 6 PLCS 250 THRU 200 THRU 520 THRU B...

Страница 20: ...al wall box to allow room for the raised areas surrounding the knockouts See chapter 2 for details on installing the buffers The light gray area represents the layout of the electrical box 3 75 H x 3...

Страница 21: ...RGB 324 326 340 Dimensions and Template Dimensions and Template cont d B 8 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Отзывы: