Commands
ASCII
Hex
Response
Set Fade To Black
Fade Screen
B
42
Blk 1
↵
Clear Fade To Black
Fade Screen
b
62
Blk 0
↵
Unit Reset
Reset Unit
Esc P 99
↵
1B+50+39+39
Updated
↵
Query Software Version
Q/q
51/71
QVER
↵
Request Part Number
N/n
4E/6E N60-243-01
↵
(for RGB 302)
N60-244-01
↵
(for RGB 304)
Request Information
I/i
49/69
Hph
•Vph
•Brt
•Pkg
•Syn
•Mem
•Exe
•Mut
•Blk
•Fnc
•Hrt
•Vrt
↵
Example: Hph-112•Vph+009•Brt+000•Pkg1•Syn6•Mem1•Exe1•Mut0•Blk0•Fnc1•Hrt
031.47•Vrt059.94
↵
Where:
Horizontal Shift (Hph)
=
-112
Vertical Shift (Vph)
=
+9
Level (Brt)
=
0
Peaking (Pkg)
=
1
Sync Mode (Syn)
=
6 (Separate H & V with H = negative
and V = positive)
Memory Cycling (Mem)
=
1 (Enabled)
Executive Mode (Exe)
=
1 (On – Front Panel Locked Out)
Backlite Automode (Mut)
=
0 (Off – Backlite stays lit)
Fade to Black (Blk)
=
0 (Off – Not faded)
Menu Language (Fnc)
=
1 (Menu language is English)
Horizontal Scan Rate (Hrt) =
31.47 kHz
Vertical Scan Rate (Vrt)
=
59.94 Hz
Error Codes
Code
Description
E10
Invalid command
E13
Invalid value (too large)
E14
Illegal command for this configuration (DIP Switch 1
is set ON for Digital Display Sync Processing and
Horizontal/Vertical Shift is requested)