Extron electronics PowerCage MTP AV Series Скачать руководство пользователя страница 1

68-1643-01 Rev. A

08 10

MTP Twisted Pair Transmitter and Receiver Modular Boards

PowerCage

 MTP AV Series 

User Guide

PowerCage Products

Содержание PowerCage MTP AV Series

Страница 1: ...68 1643 01 Rev A 08 10 MTP Twisted Pair Transmitter and Receiver Modular Boards PowerCage MTP AV Series User Guide PowerCage Products...

Страница 2: ...rksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bev...

Страница 3: ...with the instruction guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Страница 4: ...3 Installing the Boards into the PowerCage Enclosure 3 Connections LEDs and Encoders 4 PowerCage Front Panel Port Control and Indicators 6 Operation 7 Reference Information 8 Specifications 8 Part Num...

Страница 5: ...ted Pair boards that are exclusively for use in Extron PowerCage 1600 enclosure They can be used with any CAT 5 5e or 6 cable or with Extron Enhanced Skew Free A V UTP cable for cable runs of 1 000 fe...

Страница 6: ...Hot swappable components allow the user to replace boards or install additional transmitter and receiver boards any time for quick and easy upgradeability or expansion without the need to power down t...

Страница 7: ...able remove as many blank plates or previously installed boards from the rear of the PowerCage as necessary for the number of new boards to be installed 2 Hold the board with the signal connectors tow...

Страница 8: ...ect suitable display devices to the BNC connectors for composite video Vid or S video output Y C b Audio connector 5 pole captive screw MTP T AV board Connect an audio input source to the 5 pole capti...

Страница 9: ...o a suitable MTP receiver via this connector Terminate the cable as shown on the right using the same standard A or B at both ends MTP R AV board Connect the twisted pair cable from the transmitter to...

Страница 10: ...h fiber optic boards only where installed This LED lights to indicate that light is received on the fiber optic board Rx connector at this location i Comm Select button Repeatedly press this button to...

Страница 11: ...powered up the system is fully operational If any problems are encountered verify that the cables are routed and connected properly and that all display devices have suitable resolutions and refresh r...

Страница 12: ...V to 1 5 Vp p with no offset Impedance 75 ohms Return loss 30 dB DC 10 MHz DC offset max allowable 250 mV Video output PowerCage MTP R AV Number signal type 1 S video or composite video Connectors 2...

Страница 13: ...e 6 shielded or unshielded Power consumption Each MTP board at 115 VAC 60 Hz MTP T AV 2 69 watts MTP R AV 3 92 watts Power input requirements 12 VDC 1 0 A supplied by the PowerCage enclosure Temperatu...

Страница 14: ...Accessory Part number Enhanced Skew Free A V UTP cable 26 569 0x Enhanced Skew Free A V cable 1000 ft non plenum 22 141 03 Skew Free UTP P series A V cable 75 ft 22 8m 26 570 07 Enhanced Skew Free A...

Страница 15: ...Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore...

Отзывы: