Extron electronics MVC 121 Скачать руководство пользователя страница 15

MVC 121• Remote Control

MVC 121• Remote Control

Remote Control

3-3

is invalid or it contains invalid parameters, it returns an error
response to the host.

The error response codes and their descriptions are as follows:

E01 – Invalid channel number
E10 – Invalid command
E13 – Invalid value (the number is out of range)
E14 – Invalid command at this time (input on/off command not

valid during contact closure mute)

E23 – Firmware update failure

Using the command/response table

The command/response table lists valid command ASCII codes,
the MVC’s responses to the host, and a description of the
command’s function or the results of executing the command.
Lower case characters are acceptable in the command field only
where indicated.  The ASCII to HEX conversion table below is
for use with the command/response table.

ASCII to HEX  Conversion Table

3-2

RS-232 Programmer’s Guide

The MVC 121 can be remotely controlled via a host
computer attached to the rear panel’s 3-pole captive
screw RS-232 connector.  The protocol is 9600 baud,
1 stop bit, no parity, and no flow control.

The RS-232 control device (host) can use either Extron’s Simple
Instruction Set (SIS) commands or the graphical control
program for Windows.  Windows control software is included
with the MVC.

The rear panel’s RS-232 3-pole female connector has the
following pin assignments:

Pin

RS-232 function

Description

1

Tx

Transmit data

2

Rx

Receive data

3

Gnd

Signal ground

Host-to-MVC communications

SIS commands consist of one or more characters per field.  No
special characters are required to begin or end a command
sequence.  When a command is valid, the MVC executes the
command and sends a response to the host device.  All respon-
ses from the MVC to the host end with a carriage return and a
line feed (CR/LF = 

), which signals the end of the response

character string.  A string is one or more characters.

MVC-initiated messages

When a local event such as a front panel or contact closure
selection or adjustment takes place, the MVC sends a message
to the host.  No response is required from the host.  One MVC-
initiated message is listed here (underlined).

(C) Copyright 2004, Extron Electronics, MVC 121, V x.xx 
The MVC issues the copyright message when it first powers on.
V x.xx is the firmware version number.

Other examples of unsolicited responses are indicated in the SIS
command/response table by a   following every description of
a response that could also be an unsolicited response.

Error responses

When the MVC 121 receives a valid SIS command, it executes
the command and sends a response to the host device.  If the
MVC is unable to execute the command because the command

RS-232

Tx Rx

The command/response table uses symbols (defined below) to
represent variables.

The SIS on/off commands and the equivalent front panel
operations have equal priority.  The MVC will respond
to the latest settings from either SIS commands or front
panel operations.

Symbol definitions

= CR/LF (carriage return/line feed) (hex 0D 0A)

= Space
= Every response that could also be an unsolicited response

will have this symbol at the end of each description of that
response.

X1

= Master (output) volume adjustment range (0 – 92),

default = 50 (-30 dB), gain (dB) = 

X1

 - 80

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание MVC 121

Страница 1: ...ad 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81...

Страница 2: ...lten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger...

Страница 3: ...screws Use 2 mounting holes on opposite corners VersaTools Rack Shelf 1 4 Rack Width False Front Face Plate DIS TR IBU TIO N AM PL IFI ER DIS TR IBU TIO N AM PL IFI ER MIX ER VO LU ME CO NT RO LL ER M...

Страница 4: ...power is disabled regardless of its DIP switch position 3 Mic 1 and Mic 2 input connector Up to two mono microphones balanced and or unbalanced may be connected 4 Main 3 line level input connector Co...

Страница 5: ...de 3 2 Host to MVC communications 3 2 MVC initiated messages 3 2 Error responses 3 2 Using the command response table 3 3 Command response table 3 5 Windows based Program Control 3 9 Installing the so...

Страница 6: ...ents cont d MVC 121 Mic Line Mixer 1 Chapter One Introduction About the MVC 121 Features ii 68 793 01 Rev B Printed in the USA 05 04 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 9112...

Страница 7: ...ain attenuation and control of output volume RS 232 control also includes the capability to turn the inputs and output on off The latest firmware can be uploaded using RS 232 and the Extron control pr...

Страница 8: ...gh quarter rack wide MVC can be set on a table mounted on a rack shelf mounted under a desk or tabletop or mounted on a projector bracket Tabletop use Each MVC comes with rubber feet For tabletop use...

Страница 9: ...with the slots in the brackets and place the MVC against the surface with the screws through the bracket slots See the illustration below Mounting the MVC to furniture 7a Slide the MVC slightly forwa...

Страница 10: ...ck the no load power supply output with a voltmeter After making any adjustments to the MVC 121 either via the front panel controls SIS commands or the Extron Audio Products Control Program wait at le...

Страница 11: ...p Ring Balanced Stereo Input high impedance high impedance 600 ohms 600 ohms 600 ohms 5 Variable output connector The balanced unbalanced stereo output to an amplifier from the 5 pole 3 5 mm captive s...

Страница 12: ...put from this 5 pole 3 5 mm captive screw connector is output at a fixed volume level for input to a recording device Volume level can be adjusted at the recording device The Master volume control kno...

Страница 13: ...ron Audio Products Control Program or the SIS commands See Setting output volume range limits and Using the command response table in chapter 3 2 13 Turning channels on off To turn a channel off turn...

Страница 14: ...volume control knobs are locked although the Gain Volume level LEDs will still show the current gain volume settings if any knobs are rotated slightly For a muted input no gain volume level will be d...

Страница 15: ...ed to begin or end a command sequence When a command is valid the MVC executes the command and sends a response to the host device All respon ses from the MVC to the host end with a carriage return an...

Страница 16: ...n X2 X3 Set input X2 to X3 where X3 0 off 1 on 2 mute by contact closure An input while muted by contact closure is not affected by SIS commands or front panel operations See Note below View input on...

Страница 17: ...of input X2 in 1 dB steps View input gain level X2 G g X4 Show the gain X4 of input X2 These commands use both uppercase and lowercase characters e g X or x X x I or i I i etc Update firmware Upload f...

Страница 18: ...tware To run the software 1 Double click the Audio Products Control Program icon in the Extron Electronics program group 2 Click the comm port that is connected to the unit s remote connector 3 Click...

Страница 19: ...der loads the update The firmware update file must have an s19 extension If it does not have that extension it will not work properly 6 When the program is finished loading the update click Exit The w...

Страница 20: ...Contact closure Description 1 Connect pin 1 to Gnd Mute input Mic 1 2 Connect pin 2 to Gnd Mute input Mic 2 3 Connect pin 3 to Gnd Mute input Main 3 Gnd Signal ground Contact closure mute has higher p...

Страница 21: ...part 60 190 20 or 60 604 20 furniture mountable with optional under desk mounting brackets 70 212 01 and projector mountable with kit 70 217 01 Enclosure type Metal A 2 Specifications Audio Gain from...

Страница 22: ...VersaTools rack shelf 60 604 20 1U Universal rack shelf 60 190 01 1U Basic rack shelf 60 604 01 6 Deep 1U rack shelf kit 60 190 10 6 Deep Basic 1U rack shelf 60 604 10 Mini under desk mounting bracket...

Страница 23: ...MVC 121 Specifications Parts Accessories Specifications Parts and Accessories cont d im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Отзывы: