background image

 

MTP AV Series • Installation

9

Transmitter and Receiver Throughput Connections

Figure

 

12

 identifies the connections between the transmitter and receiver. 

12V

0.5A

MAX

OUTPUT

PO
WER −   

+

MTP Transmitters

MTP Receivers

INPUT

L

R

MTP T AV

OUTPUT

VIDEO

12V

0.5a

INPUT

MTP T SV A RCA

OUTPUT

MAX

12V

0.5a MAX

S-VIDEO

L

R

OUTPUT

MTP R SV A RCA

INPUT

S-VIDEO

12V

0.5a MAX

OUTPUT

MTP R AV

L

R

INPUT

VIDEO

12V

0.5a MAX

R

L

1

1

1

Figure 12. 

Throughput Connections

CAUTION:

  Do not connect these devices to a computer data network or a 

telecommunications network.

NOTE:

  RJ-45 termination must comply with the TIA/EIA T 568A or TIA/EIA T 568B 

wiring standards for all connections (see

 figure 13)

.

a

 

Transmitter output and receiver input connector 

— Connect one end of a TP cable 

to this RJ-45 female connector on the transmitter. On the MTP T AV AAP the connector 

is at the end of a short pigtail.
Connect the free end of the same TP cable from the transmitter to the RJ-45 female 
connector on the receiver.

Содержание MTP R AV

Страница 1: ...User Guide MTP AV Series Twisted Pair Video and Audio Twisted Pair Transmitters and Receivers 68 732 01 Rev I 12 11...

Страница 2: ...en da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das...

Страница 3: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to...

Страница 4: ...ention to important information TIP A tip provides a suggestion to make working with the application easier WARNING A warning warns of things or actions that might cause injury death or other severe c...

Страница 5: ...itter and Receiver Throughput Connections 9 Power Connection All Models 11 Receiver Output Connections 12 Operation 14 Front Panel Features 14 Troubleshooting Skew Delay Compensation 14 Reference Info...

Страница 6: ...MTP AV Series Contents vi...

Страница 7: ...nce Y and chrominance C or composite video Audio input is either balanced or unbalanced audio on captive screw connectors as well as unbalanced audio on RCA connectors The transmitters sum the left an...

Страница 8: ...ced The transmitters and receivers are designed for and perform best with Extron Enhanced Skew Free AV cable CAT 5 cables are acceptable but are less preferable We also recommend the use of pretermina...

Страница 9: ...h if Your installation mixes a transmitter and receiver from different generations You want the units to transmit stereo audio You want one unit to remotely power another Use the table below to identi...

Страница 10: ...knobs 3 Lift the cover straight up 4 If the transmitter or receiver is an audio unit remove and retain the two screws that secure the audio board to the main video board see figure 2 5 Pull the audio...

Страница 11: ...it in place with the screws removed in step 4 8 If the receiver is an audio unit locate the jumper block on the audio board see figure 4 Shift the jumper to the alternate location Receiver Rear Panel...

Страница 12: ...o the main video board see figure 6 Lift the audio board out of the way Remove these standoffs Figure 6 Removing the Audio Board 4 Locate the jumper block see figure 7 on the video board Shift the jum...

Страница 13: ...tions a S video connector SV models Connect an S video input to this 4 pin mini DIN connector b Composite video connector AV models Connect a composite video input to this connector female RCA on the...

Страница 14: ...output NOTES When making connections for the MTP from existing audio cables see figure 10 to identify the tip ring and sleeve wires in various connectors A mono audio connector consists of the tip an...

Страница 15: ...12V 0 5a MAX R L 1 1 1 Figure 12 Throughput Connections CAUTION Do not connect these devices to a computer data network or a telecommunications network NOTE RJ 45 termination must comply with the TIA...

Страница 16: ...e pairs of this cable have virtually identical lengths and should be used to transmit the video signals The orange pair of this cable has a different length and should not be used to transmit the vide...

Страница 17: ...ing WARNING The two power cord wires must be kept separate while the power supply is plugged in Remove power before wiring NOTES If the transmitter and receiver are either older generation units or ju...

Страница 18: ...er receptacle The blue connector does not have an extended tail or the included tie wrap Alternatively an optional Extron PS 124 Universal 12 VDC Power Supply part number 60 1022 01 can power multiple...

Страница 19: ...tin the wires Figure 17 Captive Screw Connector Wiring for Audio Output NOTE Some receivers do not have audio connections CAUTIONS Connect the sleeve to ground Connecting the sleeve to a negative term...

Страница 20: ...for luminance Y and chrominance C on S video MTP receivers If the chrominance setting on the MTP receiver S video output is too low the image may appear in monochrome Adjust the chrominance C gain un...

Страница 21: ...45 Nominal level 1 Vp p for Y of S video and for composite video 0 3 Vp p for C of S video Minimum maximum levels 0 3 V to 1 5 Vp p with no offset Impedance 75 ohms Return loss 30 dB DC 10 MHz DC offs...

Страница 22: ...onnector 5 pole MTP T AV SV A RCA MTP T AAP 1 pair of RCA female MTP R Series 1 female RJ 45 shielded Impedance 5 6k ohms 5 unbalanced 10k ohms 5 balanced Nominal level 10 dBV 0 32 Vrms Maximum level...

Страница 23: ...on no vents Mounting Rack mount MTP T AAP Series Yes with optional rack panel All other models Yes with optional 1U deep rack shelf Furniture or wall mount MTP T AAP Series Yes with optional AAP mount...

Страница 24: ...2 03 AAP 106 panel black 60 531 02 AAP 201 panel half rack width 1U black 60 302 02 AAP 301 panel full rack width 1U black 60 632 02 AAP 302 panel full rack width 2U black 60 633 02 Accessories Access...

Страница 25: ...ck red quantity 10 100 477 01 CAT 6 jack blue quantity 10 100 478 01 CAT 6 jack orange quantity 10 100 479 01 CAT 6 jack gray quantity 10 100 480 01 CAT 6 jack white quantity 10 100 481 01 CAT 6 jack...

Страница 26: ...ion of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratin...

Страница 27: ...n Europe Africa and the Middle East Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135...