MTP AV Series • Installation
11
Power Connection (All Models)
to identify the power connections, indicators, and panel screws.
MTP Transmitters
MTP Receivers
MTP AAP Transmitters
INPUT
MTP T SV A RCA
OUTPUT
S-VIDEO
L
R
OUTPUT
MTP R SV A RCA
INPUT
S-VIDEO
R
L
12V
0.5a MAX
12V
0.5a MAX
AUDIO IN
VIDEO
IN
L
R
MTP T AV
12V
0.5A
MAX
OUTPUT
PO
WER − +
1
2
1
1
2
2
Figure 14.
Power Connections and Indicators
a
Power connector
— Plug the external 12 VDC power supply into this 2-pole captive
screw connector on both the transmitter and the receiver. Figure
shows how to wire
the connector.
Power Supply
Output
Cord
Captive Screw Connector
SECTION A–A
Ridges
Smooth
A
A
Tie Wrap
5
Figure 15.
Power Connector Wiring
CAUTION
:
The two power cord wires must be kept separate while the power
supply is plugged in. Remove power before wiring.
NOTES:
•
If the transmitter and receiver are either older generation units or jumper
configured to the stereo audio position (compatible with the older units), only a
single device needs to be powered in a two-unit system (see “
for Generational Compatibility
” on page 3). The device connected to the
power supply, in turn, provides power to its counterpart. This remote power
application is only available in stereo mode, not mono mode.
•
If the transmitter and receiver are separated by more than 200 feet (61 meters)
of STP/UTP/FTP cable, connect a power supply to both units.
•
Do not tin the stripped power supply leads before installing the captive screw
or direct insertion connector. Tinned wires could be pulled out because they are
not as secure in the captive screw and direct insertion connectors.