Extron electronics MPS 409 Скачать руководство пользователя страница 4

 

4

MPS 409 Setup Guide (Continued)

Extron 

USA - West

Headquarters

+

800.633.9876

Inside USA/Canada Only

+1.714.491.1500
+1.714.491.1517

 FAX

Extron 

USA - East

+800.633.9876

Inside USA/Canada Only

+1.919.863.1794
+1.919.863.1797

 FAX

Extron 

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040
+31.33.453.4050

 FAX

Extron 

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400
+65.6383.4664

 FAX

Extron 

Japan

+81.3.3511.7655
+81.3.3511.7656

 FAX

Extron 

China

+400.833.1568

Inside China Only

+86.21.3760.1568
+86.21.3760.1566 

FAX

Extron 

Middle East

+971.4.2991800
+971.4.2991880

 FAX

©

 

2010 Extron Electronics   All Rights Reserved.   

www.extron.com

68-1833-50 

Rev. A

07 10

Setting the Microphone Talk-Over Threshold

Microphone threshold (the volume where vocal audio is detected) and the program audio level during talkover are adjustable via SIS 
commands. See 

Audio Adjustments

 in the 

MPS 409 User Guide

 for additional SIS commands.

1. 

Speak into the microphone in a normal voice. The main program audio level should drop moderately. If not, adjust the microphone 
threshold level.

2. 

Stop speaking into the microphone. Main program audio should recover to its previous level after approximately four seconds. If 
not, adjust the microphone threshold level.

3. 

If the program audio during talkover is too loud, or too soft, adjust the program audio level.

Mic talk-over threshold

Display talk-over threshold

X*

 * 

2 #

Thr 

X*

 ]

Shows the mic threshold 
number.

  

X*

 = 0 through 15, 

default = 8.

Decrement threshold

 – * 2#

Thr 

X*

 ]

Decrements mic threshold one 
step.

Increment threshold

+ * 2#

Thr 

X*

 ]

Increments mic threshold one 
step.

View mic talk threshold