Extron electronics MLC 62 RS EU Скачать руководство пользователя страница 3

 

Product Category

 

z

Digital Input port

 — Connect a switch 

or sensor to this port to control other 
devices in the room that are connected to 
the MLC serial, IR, or relay ports. The port 
monitors the high and low states of the 
connection between the switch or sensor 
and the connected device. For the voltage 
thresholds, a voltage below 1.0 VDC is 
considered 

logic low

, and a voltage above 

1.5 VDC, 

logic high

. When a threshold 

between the states is crossed (from high 
to low and vice versa), the selected action 
occurs. 
By default, this port is configured with a 
+5 VDC pull-up resistor for use with basic 
non-powered switches. If the device being 
connected has its own power source, 
configure the port to disable the pull-up 
mode (see the configuration program 
help file for port setup procedures). To 
wire this port, see the example above. 
 

5. 

Connect and apply power.

 

Connect the included power supply to the 
MLC Pwr connector as shown at right, then 
connect power to all devices in the system.

6. 

Connect the MLC to the computer.

 

Use either of the following methods:

 

z

Connect a USB A-to-USB mini B cable 
between the 

USB configuration 

port

 on the MLC side panel and a USB 

port on your computer as shown at 
right; 

or

 

z

Wire an RS-232 cable to the provided 
3-pole connector and connect it 
between the MLC 

Host/Config port

 

and the computer serial port, as 
shown below.

RELAYS

   N

/O

 PW

R

12 

V

0.4 A ma

x

 H

O

S

T

/  

CONFIG

D

IG

IT

A

L

 IN

P

U

T

+

Tx

Rx

1

Tx

Tx/

IR

1

2

C

12

R

PORT 

A

RS-232

PORT 

B

IR/ 
S

MLC 62 RS EU or MK
Rear Panel

To RS-232 Port on Computer 
or Control System

9-pin HD

Connector

Ground 

Rx

Receive

Transmit

Tx

3

Transmit (Tx)

Receive (Rx)

2

Ground

5

5

1

9

6

7. 

Configure the MLC buttons and ports

 (see the

 MLC 60 Series Configuration Program Help File

 for the procedures). 

a. 

Load and install the configuration software to your computer from the Extron website or the provided DVD.

b. 

Obtain device drivers. Drivers for the devices that will be connected to the MLC rear panel IR and serial ports can be 
obtained from the provided MLC software DVD or downloaded from the Extron website at 

www.extron.com

. You 

can also obtain them using the configuration software if an Internet connection is available. 

c. 

Upload the configuration to the MLC.

3

RELAYS

   N

/O

 PW

R

12 

V

0.

A

 m

ax

 H

O

S

T

/  

CONFIG

D

IG

IT

A

L

 IN

P

U

T

+

Tx

Rx

1

Tx

Tx/

IR

1

2

C

12

R

PORT 

A

RS-232

PORT 

B

IR/ 
S

Ground

Digital Input

MLC RS EU or MK Rear Panel

Two-position Switch

SECTION  A–A

A

A

Power Supply

Output Cord

Ridges

Smooth

MLC RS EU or MK
Rear Panel

RELAYS

   N

/O

 PW

R

12 

V

0.4 A max

 HOST/ 

 

CONFIG

D

IG

IT

A

L

 IN

P

U

T

+

Tx

Rx

1

Tx

Tx/

IR

1

2

C

12

R

PORT 

A

RS-232

PORT 

B

IR/ 
S

Ground
12 VDC Input

Ground all devices.

USB Cable

Type 

A

USB

Mini Type 

B

USB

USB 1

PC
USB A
Ports

MLC 62 RS EU or MK 
Left Side Panel

Отзывы: