ISS 608 • Setup Guide (Continued)

Configure and Recall a Logo Preset

NOTE:

  User images must first be uploaded via Extron Product Configuration Software (PCS) available at 

www.extron.com

.

To configure a logo preset 

(see 

figure 4

 on page 2):

1. 

Press the 

MENU

 button (

C

) to go to the 

Background/Logo

 

Configuration

 menu. 

2. 

Press the 

NEXT

 button (

C

) to go to the 

Logo

 

Select

 submenu. 

3. 

Rotate the 

ADJUST

 

[

 knob (

G

) to select the logo preset to configure.

4. 

If needed, rotate the 

ADJUST

 

{

 knob (

G

) to change the assigned image file (the image file shows on the preview output).

5. 

Press the 

NEXT

 button to adjust the position of the logo.

6. 

Rotate the 

ADJUST

 

[

 knob to adjust the horizontal (

H

) position and rotate the 

ADJUST

 

{

 knob to adjust the vertical (

V

position.

7. 

Press the 

NEXT

 button to select a 

Logo

 

Key

 

Effect,

 if desired.

8. 

Rotate the left and right 

ADJUST

 knobs to select the 

Logo

 

Key

 

Effect

 (

Transparency

RGB

Level

, or 

Alpha

).

To recall a logo preset:

1. 

Press the 

LOGO

 button (if no logo preset was previously selected, 

Logo

 

Error

 shows on the LCD screen for 2 seconds).

2. 

Rotate the 

ADJUST

 

knob to select the logo preset.

3. 

Wait a second or press the 

NEXT

 button and the logo preset is recalled onto the preview output.

4. 

Press the 

TAKE

 button to switch the preview output, with the included logo preset, to the program output using the selected 

effect, displaying the logo preset on the program output.

• 

A different logo preset can be recalled or removed on the preview output by pressing the 

LOGO

 button again.

5. 

Press the 

TAKE

 button again to switch the preview output to the program output.

• 

If a different logo preset was recalled on the preview output, the new logo preset is displayed on the program output.

• 

If no logo preset is on the preview output, the logo on the program output is removed.

NOTE:

 The 

LOGO

 button lights solid if there is a logo on preview output but not on program output. The 

LOGO

 button 

blinks if there is a logo on program output whether there is a logo on preview output or not.

Recall Layout Presets

Layout presets are used to preconfigure a presentation prior to going live. This minimizes missed cues or incorrect video layout. A 
layout preset captures transition effect settings, a logo preset, the input channel, and any picture control adjustments made to the 
preview output. When recalled, layout presets apply the settings to the preview output to review the configuration before 

TAKE

 is 

pressed to make it live on the program output.

1. 

Press the 

RECALL

/

SAVE

 button (see 

figure 4

D

 on page 2) to go to the 

Recall

 

Layout

 menu.

2. 

Rotate either 

ADJUST

 knobs to select a saved 

Layout

 

Preset

.

3. 

Press the 

ENTER

 button to recall the selected preset to the preview output.

Adjust the size and position of the Program or Preview 

The size and position of the program or preview can be adjusted using the 

ADJUST

 

SIZE

 and 

POSITION

 buttons (

E

).

• 

Press 

SIZE

 or 

POSITION

 buttons to toggle between the 

PREVIEW

 image and the 

PROGRAM

 image adjustments.

• 

When the 

PIP

 (

C

) effect is selected, the 

SIZE

 and 

POSITION

 buttons cycle through the 

PIP

 window, 

PIP

 image, and 

program image adjustments.

ISS 608 Configuration

To configure the ISS 608 switcher, available methods include front panel controls, Extron Product Configuration Software (PCS), 
and Simple Instruction Set (SIS) Commands.

• 

Front Panel Controls

 

To configure network settings using the front panel controls:

1. 

Press 

MENU

 (

G

) repeatedly to access the 

View

 

Comm

 

Settings

 submenu.

2. 

Press and hold 

NEXT

 for approximately 5 seconds until the submenu changes to 

Edit

 

Comm

 

Settings

.

Содержание ISS 608

Страница 1: ...et button and LED C DisplayPort input connectors G LAN connector D HDMI output connectors H Remote RS 232 connector Connections Step 1 Mounting Turn off or disconnect all equipment power sources For tabletop use affix the rubber feet and remove the brackets For optional rack mounting mount in a rack via the attached brackets see figure 2 Step 2 Video inputs HDMI input connectors 1 through 6 Connec...

Страница 2: ...CD screen reverts to its default display cycle alternating between three displays two showing the selected program and preview inputs and their rates and the third showing the selected output rate 2 sec 2 sec Default Display Cycle Extron ISS 608 60 1684 01 FW Ver 1 00 Prog 01 HDMI 1080p 60Hz 720p 60 Hz Prev 08 DP Output Rate 1080p 60Hz Power on Extron Electronics 2 sec Front Panel Operations ISS 6...

Страница 3: ...on to recall the selected preset VIDEO KEY Video on the preview bus can be keyed to appear over the existing video on the program bus using an RGB key a luminosity level key or a transparency effect To configure 1 Select the VIDEO KEY button to go to the Video Key Effect submenu 2 Rotate the ADJUST knobs to select the key effect Available options are Transparency RGB or Level 3 Select the NEXT but...

Страница 4: ...isplayed on the program output If no logo preset is on the preview output the logo on the program output is removed NOTE The LOGO button lights solid if there is a logo on preview output but not on program output The LOGO button blinks if there is a logo on program output whether there is a logo on preview output or not Recall Layout Presets Layout presets are used to preconfigure a presentation p...

Страница 5: ...utX InX Vid Tie input X to output X Vid Tie input to output audio only X X OutX InX Aud Tie input X to output X Aud KEY X Input number 1 8 two digit response with 0 padding X Output number 1 Preview 2 Program Take effect select Set Take effect EO1 X1 2 SWEF SwefO1 X1 Sets the Take effect to X1 View setting EO1SWEF X1 View current setting Default 0 KEY X1 Take video effect 0 Cut 1 Dissolve 2 Wipe 3...

Страница 6: ... front panel lockout 2 Exe Mode 2 Partial front panel lockout Menu and Next buttons disabled 3 Exe Mode 3 Program lockout all changes to Program are locked out LAN IP Configuration and Setup Set DHCP mode EX1 DH Idh X1 Set IP address EX9 CI Ipi X9 Default 192 168 254 254 Set subnet mask EX9 CS Ips X9 Default 255 255 0 0 Set gateway IP address EX9 CG Ipg X9 Default 0 0 0 0 Set DNS server IP address...

Отзывы: