IPL T SF24 and IPL T SFI244 • Installation and Operation
Installation and Operation, cont’d
IPL T SF24 and SFI244
3
Chapter Three
Connection and Configuration
Connecting the Hardware
Configuring the Hardware
2-12
•
If the events are currently stopped following the
momentary (<1 second) press, the Power LED
will
flash twice
indicating the starting of events.
or
•
If events are currently running following the
momentary (<1 second) press, the Power LED will
flash three times
indicating the stopping of events.
Each flash will last for .25 seconds. Nothing happens if
the momentary press does not occur within 1 second.
Mode 4
— Holding the Reset button until the Power LED blinks
twice
(6 seconds) followed by a momentary (<1 second)
press will reset IP settings. The Power LED will blink four
times in quick succession, confirming a Mode 4 reset. This
mode will
1
. Enable ARP program capability.
2
. Set IP back to factory IP.
3
. Set Subnet back to factory default.
4
. Set Gateway back to factory default.
5
. Set port mapping back to factory default.
6
. Turn DHCP off.
7
. Turn events off.
Nothing happens if the momentary press does not occur
within one second.
Mode 5 —
Holding the Reset button until the Power LED
blinks three times (9 seconds) followed by a momentary
(<1 second) press will cause an absolute system reset back
to factory default conditions. Nothing happens if the
momentary press does not occur within 1 second. The
power LED will
blink four times in quick succession,
confirming a Mode 5 reset.