background image

Extron Electronics, USA

1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500  
Fax 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040  
Fax +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400  
Fax +65.6383.4664

Extron Electronics, Japan

Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan 
+81.3.3511.7655  
Fax +81.3.3511.7656

www.extron.com

© 2003  Extron Electronics.  All rights reserved.

User’s Manual

IP Link Tools

68-738-06 

Rev. A

Printed in the USA

11 03

IPL T SF24 and SFI244 Series

Содержание IPL T SF24 Series

Страница 1: ...50 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2003 Extron Electronics All rights reserved User s Manual IP Link Tools 68 738 06 Rev A Printed in the USA 11 03 IPL T SF24 and SFI...

Страница 2: ...werden können Wartung Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal durchgeführt werden Die internen Komponenten des Gerätes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Gerät selbst öffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und Öffnungen Wenn d...

Страница 3: ...ce QS 1 Quick Start Guide IPL T SF24 and SFI244 COM1 TX RX TX RX COM2 LAN 00 05 A6 xx xx xx POWER 12V 5A MAX FLEX I O 2 1 3 4 1 IR 2 3 4 G S G S G S G S 2 4 40 x 3 16 Screws Use 2 mounting holes on opposite corners 1U Rack Shelf 1 4 Rack Width False Front Face Plate IPL T SFI2 44 1 R 100 COM TX IR LINK ACT 2 RX RTS CTS 2 4 1 3 2 4 I O IR IPL T SFI 244 1 R 100 CO M TX IR LIN K ACT 2 RX RTS CTS 2 4 ...

Страница 4: ...t 4 4 Analog input 4 5 Bidirectional serial control interface ports 4 5 Table of Contents iii QS 2 Extron IPL T RLY4 Relay Box Lighting System CO M1 TX RX TX RX CO M2 LA N 00 05 A6 xx xx xx PO WER 12 V 5A MA X FL EX I O 2 1 3 4 1 IR 2 3 4 G S G S G S G S Screen Control Extron IPL T SFI244 Ethernet Control Interface RS 232 RS 232 DVD 1 VCR DVD 2 Extron IR Emitters Projector Ethernet Remote User Con...

Страница 5: ...asswords 4 10 Editing and adding e mail alerts 4 11 Upgrading the firmware 4 12 Managing files 4 13 IR Learning SFI244 only 4 14 Creating a driver with the IR Learner software 4 15 Programmer s Guide for the Telnet and Web Browser 4 16 Using the command response table 4 16 Symbol definitions 4 18 Copyright information 4 21 Password information 4 21 Error responses 4 22 References to errors 4 22 Co...

Страница 6: ...IPL T SF24 and SFI244 1 Chapter One Introduction About this Manual About the IPL T SF24 and SFI244 Interfaces Features ...

Страница 7: ...2 and the IPL T SFI244 Extron part 60 544 06 Ethernet control interfaces It includes information on how to install configure and operate each system When information in this manual applies to both models they may be referred to generally as an IPL T unit or interface About the IPL T SF24 and SFI244 Interfaces The Extron IPL T interfaces SF24 and SFI244 are Ethernet based control interfaces designe...

Страница 8: ...Explorer V5 5 Netscape V6 0 or higher and Web based interface Using a standard Telnet client application Requires no centralized processor to operate within a system Choice of mounting options Can be mounted under a desktop or podium on a projector mount or on a rack shelf Remote management Allows you to remotely manage projectors cameras video conferencing equipment switchers and other A V equipm...

Страница 9: ...es See Connecting the Hardware in chapter 3 4 Connect power cords and turn on the devices in the following order output devices projectors monitors speakers the IPL T unit a serial controller or computer PC then all input devices DSS cable boxes etc 5 Configure the IPL T interface through Telnet then access the IPL T interface using an Internet browser Mounting the IPL T Interface Rack mounting Fo...

Страница 10: ...r Extron part 70 217 01 projector as follows 1 Attach the mounting brackets to the interface with the machine screws provided figure 2 3 2 If feet were previously installed on the bottom of the interface remove them 3 For furniture mounting hold the interface with the attached brackets against the underside of the table or other furniture Mark the location of the screw holes of the bracket on the ...

Страница 11: ...gure 2 8 COM1 and COM2 9 pin D connector pin assignments SF24 only Pin Function RS 232 RS 422 RS 485 2 3 5 7 8 Receive Data Receive Data Transmit Data Transmit Data Signal Ground Request to Send Transmit Data Clear to Send Receive Data RX TX GND RTS CTS RX TX GND TX RX Data Tie 2 3 GND Data Tie 7 8 2 6 Figure 2 6 Power connector wiring Do not tin the stripped power supply leads before installing t...

Страница 12: ...re 2 9 Example application using I O ports Operation Connect power cords and turn on the display output devices projectors monitors VCRs control devices switchers scalers distribution amplifiers interface and input devices PC laptop network equipment Check indicator LEDs on the PC laptop on the interface and on the network hub router etc to ensure that all devices are plugged in and communicating ...

Страница 13: ...bled the COM port Mode 3 Holding the Reset button until the Power LED blinks once 3 seconds followed by a momentary 1 second press will turn events either on or off depending on the current state of the events 2 11 2 10 1 On Off indicator LED A green LED lights to indicate that the interface is receiving power 2 Reset button recessed See Resetting the unit later in this chapter for details on this...

Страница 14: ...on until the Power LED blinks twice 6 seconds followed by a momentary 1 second press will reset IP settings The Power LED will blink four times in quick succession confirming a Mode 4 reset This mode will 1 Enable ARP program capability 2 Set IP back to factory IP 3 Set Subnet back to factory default 4 Set Gateway back to factory default 5 Set port mapping back to factory default 6 Turn DHCP off 7...

Страница 15: ...SAV E 4 3 2 1 1 2 I O INP UTS OUT PUT S RS 232 Projector Extron Crosspoint Switcher RS 232 TCP IP Network 3 2 Connecting the Hardware To connect the IPL T interface connect the input and output devices to the unit using figure 3 1 as a guide Please note prior to connecting the IPL T unit to a local area network LAN you must initially connect a PC directly to the IPL unit and change the default IP ...

Страница 16: ... it Refer to Ethernet connection in this chapter for additional information IPL T interface configuration Configuring the IPL T using the ARP command You can make use of the ARP Address Resolution Protocol command to set up an IP address for your IPL T interface The ARP command tells your computer to associate the IPL T unit s MAC address with the assigned IP address You must then use ping to acce...

Страница 17: ... other end of the Ethernet cable into the Ethernet port on your PC 3 Right click on the Network Neighborhood or My Network Places icon on your Windows 98 2000 NT ME XP desktop and select Properties from the menu 3 7 3 6 In order to use this setup method both your computer and IPL T interface must be connected to the same LAN Or you may use a crossover Ethernet cable to connect the device server di...

Страница 18: ... note of that instead IP Address Subnet Mask 6 Click on Specify an IP address or Use the following IP address depending on your operating system and leave the default gateway blank Enter the following values IP address 192 168 254 253 Subnet mask 255 255 0 0 7 Save the changes and exit the Network setup Reboot the PC if required for the changes to become effective 8 Launch your Web browser Netscap...

Страница 19: ...ivating the 5VDC and 2K pull up resistor Figure 4 4 Sample wiring for a digital input reading an external pushbutton switch 4 3 I O 2K 30V 5V SW2 GND 24K Ports Overview Flex I O ports Extron Flex I O ports are configurable input or output ports designed to provide connectivity to various devices such as motion detectors alarms lights LEDs buttons photo light sensors temperature sensors relays etc ...

Страница 20: ...dard pin out and will vary from device to device Captive Screw Connectors On other IPL T units several of the serial interface ports are connected on captive screw terminals When using the ports on the captive screw terminals only RS 232 control is available and hardware handshaking is unavailable Since RS 232 is the most common control interface encountered this port configuration allows for quic...

Страница 21: ... In other words both the unit and the PC should be connected to your local intranet or the Internet If you have established passwords for the interface you will be shown a Password window when your browser accesses the IPL T unit but not when you initially access the Web server since no passwords have been established Your level of control over the interface will depend on the password you enter i...

Страница 22: ...e displayed on this page Figure 4 12 IR Driver screen 5 Click the IR driver that controls the device A separate IR interface screen figure 4 13 will display the commands in the driver 6 Select the port the IR command will be sent to 7 Execute the IR command by clicking the command link The IR LED on the front of the IPL T SFI244 unit will blink a green light verifying the sending of the IR command...

Страница 23: ...under E mail Settings 4 Click Save to keep changes 5 Click the Edit buttons to independently edit each E mail Address and File Name a Enter the e mail address of the alert recipient in one of the numeric mailboxes under E mail Address b Enter the name of the file containing the alert message under File Name 4 10 Figure 4 13 Example of the default Web interface of an eir file Setting and changing y...

Страница 24: ...and code For example the code for sending an alert from the 4th numeric mailbox would be Esc 4 SM For detailed information on creating monitoring and scheduling scripts and software see the Global Viewer Software User s Guide Upgrading the firmware Firmware upgrades will become available periodically as improvements are made to the versatility and functionality of the IPL T interface These upgrade...

Страница 25: ...t in controlling commonly used functions During IR learning the user must hold the device remote between 2 and 12 away from the IR pick up device See figure 4 18 for an example Figure 4 18 IR remote distance Creating a driver with the IR Learner software In order to use your third party remote device with the IPL T SFI244 the functions of your third party driver must be learned by the IPL T unit I...

Страница 26: ...er session For Web browsers all non alphanumeric characters must be represented as their hex equivalent such as xx where xx equals the two character representation of the hex byte that needs to be sent e g a comma would be represented as 2C Telnet Web Browser Escape Hex 1B W must not be encoded Carriage Return Hex 0D Pipe Character must not be encoded When using these commands through a Web browse...

Страница 27: ...1 user absolute 2 user relative 3 NVRAM X37 Event buffer offset range 0 MaxBufferSize Symbol definitions CR LF carriage return line feed Carriage return no line feed Space hard character X1 Specific port number 01 99 The port number will be represented as two ASCII characters 2 bytes example port 05 would be represented as 30 35 in hex 00 All ports X2 Command data section For Web encoding only Dat...

Страница 28: ...sed X55 Upper transition threshold 0 detection off for digital inputs Lower must be smaller than upper 0 4095 based on 12 bit A to D X56 Lower transition threshold 1 detection on for digital inputs Lower must be smaller than upper 0 4095 based on 12 bit A to D The default Web pages will display X55 and X56 in voltages 100mV to 24VDC upper default 2VDC and lower default 1VDC The conversion rate is ...

Страница 29: ... 0 0 Flex I O Data port Set I O mode modes 0 5 X1 X40 X1 2A X40 5B Cpn X1 Iom X40 Set I O mode modes 6 7 X1 X40 X55 X56 X1 2A X40 2A X55 2A X56 5B Cpn X1 Iom X40 X55 X56 View I O mode X1 X1 5B X40 X55 X56 Pulse I O state10 14 X1 3 X63 X1 2A 3 2A X63 5D Cpn X1 Sio X5 Toggle I O state10 14 X1 2 X1 2A 2 5D Cpn X1 Sio X5 Set I O state ON X1 1 X1 2A 1 5D Cpn X1 Sio 1 Set I O state OFF X1 0 X1 2A 0 5D C...

Страница 30: ...ser password24 Esc X33 CU W X33 CU Ipu X33 Command ASCII Telnet URL Encoded Web Response IR Serial Data port SFI244 only Send IR command 28 Esc X1 file function X59 IR Irs X1 file function X57 Get IR command info 28 Esc file function IR description text Firmware Version Part Number Information Query firmware version Q Q X11 Query verbose version information 0Q 0Q sum of responses from 2Q 3Q 4Q Que...

Страница 31: ... port 80 Load file to user flash memory Use a POST on port 80 followed by the delimited data to be written to the flash file memory Retrieve file from user flash memory Send a page GET on port 80 followed by WSF responds with raw unprocessed data in file e g http 192 168 254 254 mypage html cmd WSF Command ASCII Telnet URL Encoded Web Response Re map port designations Set Telnet port map 24 Esc po...

Страница 32: ...P Link product When a Web page is requested the Web server removes the SSI and replaces it with the answer to the SIS command within quotes Figure 4 22 Example of SSI host command In figure 4 22 above the N command is used to request the IP Link product s part number echo var SIS Command Server Side Include Using the Host SIS command type with no spaces SIS command to be processed by the IP Link N...

Страница 33: ...title head h2 b HTML Example 1 h2 b body The following lines demonstrate how to read status from the IPLink Product p IPLink Product Name b echo var 1I b br IPLink Product Description b echo var 2I b br IPLink Product Part Number b echo var N b br hr p This example requires an Extron Crosspoint 84HVA connected to IPL T SF244 serial port 1 p Part Number b echo var W01RS N b br Connection Info b ech...

Страница 34: ...point 84HVA connected to IPL T SFI244 serial port 1 p Part Number b N60 337 01 0D 0A b br Connection Info b V08X04 A08X04 Exe0 0D 0A b br Firmware Version b Ver2 02 0D 0A b 4 33 4 32 The host SSI commands in figure 4 26a request the product name product description and product part number of an IP Link device The remote SSI commands request the part number connection information and firmware versi...

Страница 35: ...cript code to determine which switcher input is selected This example also demonstrates using a URL query string in conjunction with the pulse I O command to allow the user to switch the System 8 with a 250 ms closer Figure 4 29b Browser view html head title Example 4 title head h2 b HTML Example 4 b h2 body p script var ioState1 echo var 1 var ioState2 echo var 2 if ioState1 1 ioState2 0 document...

Страница 36: ...echo var W01RS V03 25 xOut4 echo var W01RS V04 25 script head h2 b HTML Example 6 h2 b body This example requires an Extron Crosspoint 84HVA connected to IPL T SFI244 serial port 1 p b Sample links that can be followed b br a href http 192 168 254 254 example 6 html cmd W01RS 5 1 http 192 168 254 254 example 6 html cmd W01RS 5 1 a i Creates tie from input 5 to output 1 i br a href http 192 168 254...

Страница 37: ...Backslash Caret Tilde Left Square Bracket Right Square Bracket Grave Accent 20 23 22 3C 3E 25 7B 7D 7C 5C 5E 7E 5B 5D 60 Hex 32 35 123 125 124 92 94 126 91 93 96 34 60 62 37 Dec Characters Dollar Ampersand Plus Comma Forward Slash Virgule Colon Semi colon Equal Question Mark At Symbol 24 26 2B 2C 2F 3A 3B 3D 3F 40 36 38 43 44 47 58 59 61 63 64 Hex Dec alphanumerics special characters reserved char...

Страница 38: ...the IP address followed by a space then the port number e g 192 168 244 244 2001 A V Device Control Control of A V devices may be accomplished in any of several ways once the IPL T interface has been connected and configured These include Web pages Telnet and direct port access Custom Web pages These pages can either be modified versions of the existing Web pages or new Web pages developed in the ...

Страница 39: ...ing Power connections 1 Ensure that all devices are plugged in 2 Make sure that each device is receiving power The interface s front panel power LEDs light if the device is receiving power Data connections 1 Check the cabling connections and make adjustments as needed The Link LEDs on the IPL T control interface and the computer should be solid green if a network connection is detected If these LE...

Страница 40: ...and IPL T SFI244 Communication and Control Communication and Control cont d IPL T SF24 IPL T SFI244 Specs Part Numbers Accessories A Appendix A Specifications Part Numbers and Accessories Specifications Parts 4 44 ...

Страница 41: ... part 60 190 20 also under furniture mountable with optional brackets 70 212 01 or projector mountable with optional brackets 70 217 01 70 077 04 Enclosure type Metal Enclosure dimensions 1 7 H x 4 3 W x 3 0 D 1U high quarter rack width 4 3 cm H x 10 9 cm W x 7 6 cm D Depth excludes connectors Product weight 0 7 lbs 0 3 kg Shipping weight 2 lbs 1 kg Specifications Ethernet control interface Connec...

Страница 42: ...ustrial strength Velcro Female 3 5 mm 5 pole captive screw connectors 10 319 10 Female 3 5 mm 2 pole captive screw connectors 10 319 05 Tweeker IPL T SF24 and SFI244 User s Manual Optional accessories Accessories Part number 19 1U VersaTools Rack Shelf kit 60 190 20 19 1U Universal Rack Shelf kit 60 190 01 Under desk mounting bracket kit 70 077 01 Projector mount kit 70 217 01 Vibration ISTA NSTA ...

Страница 43: ...ct to a network such as the Internet When your computer or networking device router hub interface etc is connected to a LAN or the Internet a table see ARP relates the device s IP address to its corresponding physical MAC address on the LAN Glossary 10 100Base T is Ethernet which uses unshielded twisted pair UTP Cat 5 etc cable where the amount of data transmitted between two points in a given amo...

Страница 44: ...er supplies Static IP refers to an IP address that has been specifically instead of dynamically see DHCP above assigned to a device or system in a network configuration This type of address requires manual configuration of the actual network device or system and can only be changed manually or by enabling DHCP Transmission Control Protocol Internet Protocol TCP IP is the communication protocol lan...