IPL Pro Series • Setup Guide (Continued)
Reset Modes: a Brief Summary
The IP Link Pro control processors offer the following reset modes:
•
Use Factory Firmware
:
Press and hold the front panel
Reset
button while applying power to the unit. Keep holding the
button down until the Power LED blinks twice, or for 6 seconds, then release the button. The
control processor enters factory firmware mode. For units with firmware prior to version 2.
x
, the
LED blinks quickly. Use this mode to revert to factory firmware in the event of a firmware failure.
Do not continue to operate the control processor using the factory firmware version. If you want
to use the factory default firmware version, you must upload that version again.
•
Project Recovery
:
See the
IPL Pro Series User Guide
for instructions. Use this mode to recover the project in the
event of a lost user name and password.
•
Run/Stop Program
:
Hold down the
Reset
button for about 3 seconds, until the
Power
LED blinks once. Release
and press the
Reset
button momentarily (for <1 second) within 1 second. (Nothing happens if
the momentary press does not occur within 1 second.) The LED blinks 2 times if the program is
starting. The LED blinks 3 times if the program is stopping. This mode allows you to restart any
programs stopped by an IP settings reset.
•
Toggle DHCP Client
:
Press the
Reset
button five times (consecutively). Release the button. Do not press the button
within 3 seconds following the fifth press. Use this mode to enable or disable the DHCP client
for the LAN port.
•
The
Reset
LED blinks 6 times if the DHCP client is enabled.
•
The
Reset
LED blinks 3 times if the DHCP client is disabled.
NOTES:
•
DHCP toggle mode is supported on firmware version
3.0
or higher.
•
By default DHCP is off and the unit uses a static IP address.
•
When you disable the DHCP client, the unit reverts to using the previously-set static
IP address.
•
Reset All IP Settings
:
Press and hold the front panel
Reset
button for 6 seconds. After the Power LED blinks twice,
release and momentarily press the
Reset
button. Use this mode to reset all network settings
to factory default values without affecting user-loaded files. This reset mode also stops any
running programs.
•
Reset to Factory Defaults
: Press and hold the front panel
Reset
button for 9 seconds. After the Power LED blinks
three times, release and momentarily press the
Reset
button. Use this mode to return the
control processor to factory default settings. This mode also deletes all user-loaded files and
configurations.
For detailed information on each mode and its use, see the
IPL Pro Series User Guide
at
www.extron.com
.
Resources
Obtaining Control Drivers
Extron provides an extensive selection of device drivers available on the
Extron website. If the system requires a control driver that is not already
available, you have the following options:
•
You can request a new serial (RS-232) or Ethernet driver from Extron.
•
Create your own custom IR device driver using Extron
IR Learner Pro software. Follow the directions in the
IR Learner
Pro Help File
to create a driver by using the remote control for
that device and the IR receiver port on the front panel of the
IPL Pro IRS8.
Obtaining Instructions, Information,
and Assistance
A checklist of basic setup steps is provided at the
beginning of this guide. For additional information
see the help files and the
IPL Pro Series User
Guide
, available at
www.extron.com
.
If you have questions during installation and
setup, call the
Extron S3 Sales & Technical
Support Hotline
or the Extron S3 Control
Systems Support Hotline
(1.800.633.9877).
Rev. B: Changed wording of various items in the reset
modes summary:
For the Use Factory Firmware mode, changed
“replace” to “revert to factory”. Added more text
to clarify how long to hold the button, and on LED
behavior for units with versions prior to 2.x.
Per peer reviewer (Sean), added “
Do not continue
to operate the control processor using the factory
firmware version. If you want to use the factory
default firmware version, you must upload that
version again.
“
For the Reset All IP Settings mode, added “to factory
default values” and noted that the mode stops
running scripts/events.
Rev. B: Added Run/Stop Program mode and new
DHCP toggle mode.
Since rev. A: changed “ollowing” to “following” in the first sentence on pg. 7.
Corrected IPCP to IPL in the name of the user guide in the last sentence of the reset
modes summary section.