Reset Modes: a Brief Summary

The IP Link Pro control processors offer the following reset modes:

• 

Use Factory Firmware

Press and hold the front panel 

Reset

 button while applying power to the unit. Keep holding the 

button down until the Power LED blinks twice, or for 6 seconds, then release the button. The 
control processor enters factory firmware mode. For units with firmware prior to version 2.

x

, the 

LED blinks quickly. Use this mode to revert to factory firmware in the event of a firmware failure. 
Do not continue to operate the control processor using the factory firmware version. If you want 
to use the factory default firmware version, you must upload that version again.

• 

Project Recovery

See the 

IPL Pro Series User Guide

 for instructions. Use this mode to recover the project in the 

event of a lost user name and password.

• 

Run/Stop Program

Hold down the 

Reset

 button for about 3 seconds, until the 

Power

 LED blinks once. Release 

and press the 

Reset

 button momentarily (for <1 second) within 1 second. (Nothing happens if 

the momentary press does not occur within 1 second.) The LED blinks 2 times if the program is 
starting. The LED blinks 3 times if the program is stopping. This mode allows you to restart any 
programs stopped by an IP settings reset.

• 

Toggle DHCP Client

Press the 

Reset

 button five times (consecutively). Release the button. Do not press the button 

within 3 seconds following the fifth press. Use this mode to enable or disable the DHCP client 
for the LAN port. 

• 

The 

Reset

 LED blinks 6 times if the DHCP client is enabled.

• 

The 

Reset

 LED blinks 3 times if the DHCP client is disabled.

NOTES:

 

• 

DHCP toggle mode is supported on firmware version 

3.0

 or higher.

• 

By default DHCP is off and the unit uses a static IP address.

• 

When you disable the DHCP client, the unit reverts to using the previously-set static 
IP address.

• 

Reset All IP Settings

Press and hold the front panel 

Reset

 button for 6 seconds. After the Power LED blinks twice, 

release and momentarily press the 

Reset

 button. Use this mode to reset all network settings 

to factory default values without affecting user-loaded files. This reset mode also stops any 
running programs.

• 

Reset to Factory Defaults

:  Press and hold the front panel 

Reset

 button for 9 seconds. After the Power LED blinks 

three times, release and momentarily press the 

Reset

 button. Use this mode to return the 

control processor to factory default settings. This mode also deletes all user-loaded files and 
configurations.

For detailed information on each mode and its use, see the 

IPL Pro Series User Guide

 at 

www.extron.com

.

Resources

Obtaining Control Drivers

Extron provides an extensive selection of device drivers available on the 
Extron website. If the system requires a control driver that is not already 
available, you have the following options:

• 

You can request a new serial (RS-232) or Ethernet driver from Extron.

• 

Create your own custom IR device driver using Extron 
IR Learner Pro software. Follow the directions in the 

IR Learner 

Pro Help File

 to create a driver by using the remote control for 

that device and the IR receiver port on the front panel of the 
IPL Pro IRS8.

Obtaining Instructions, Information, 
and Assistance

A checklist of basic setup steps is provided at the 
beginning of this guide. For additional information 
see the help files and the 

IPL Pro Series User 

Guide

, available at 

www.extron.com

.

If you have questions during installation and 
setup, call the 

Extron S3 Sales & Technical 

Support Hotline

 or the Extron S3 Control 

Systems Support Hotline

 

(1.800.633.9877).

Rev. B: Changed wording of various items in the reset 

modes summary:

For the Use Factory Firmware mode, changed 

“replace” to “revert to factory”. Added more text 
to clarify how long to hold the button, and on LED 
behavior for units with versions prior to 2.x. 
Per peer reviewer (Sean), added “

Do not continue 

to operate the control processor using the factory 
firmware version. If you want to use the factory 
default firmware version, you must upload that 
version again.

For the Reset All IP Settings mode, added “to factory 

default values” and noted that the mode stops 
running scripts/events. 

Rev. B: Added Run/Stop Program mode and new 

DHCP toggle mode.

Since rev. A: changed “ollowing” to “following” in the first sentence on pg. 7.
Corrected IPCP to IPL in the name of the user guide in the last sentence of the reset 

modes summary section.

Содержание IPL Pro Series

Страница 1: ... yourself with the features of the control processor see Front Panel Features on page 4 and Rear Panel Features and of any TouchLink Pro touchpanels that will be part of the system Download and install the latest version of the following Toolbelt software for discovering the control processor and other control products on the network for managing core settings and for upgrading firmware when neede...

Страница 2: ...the system start and use GUI Designer to design save and build the graphical user interface GUI layout for the touchpanels Using GC create a new GC Plus or GC Professional project and configure the control processor and other IP Link Pro devices The configuration tells the control processor how its ports function what to monitor how to control other products when to do things which touchpanels to ...

Страница 3: ...ork Apply power to all devices Use the Set IP feature in Toolbelt or use the Toolbelt Manage Network Settings tab feature to enter the IP address subnet address and gateway then configure other network settings as needed Figure 1 Network Setup Mounting Securely mount the control processor and other devices and attach cables using the wiring section Cabling and Features on page 5 as a wiring guide ...

Страница 4: ... Tx Rx RTS CTS COM 6 G Tx Rx RTS CTS COM 5 LAN PoE IPL PRO S6 IPL PRO S1 LAN PoE POWER 12V 0 3A MAX POWER 12V 0 3A MAX 3 4 2 1 1 G 7 8 6 5 G G S G S INPUT 2 1 2 G S G S 7 8 G S G S 7 8 G S G S 7 8 3 4 5 6 7 8 RELAYS LAN PoE LAN PoE IR SERIAL IPL PRO CR88 IPL PRO IRS8 MAC 00 05 A6 XX XX XX S N E MAC 00 05 A6 XX XX XX S N E MAC 00 05 A6 XX XX XX S N E MAC 00 05 A6 XX XX XX S N E 00 05 A6 XX XX XX MA...

Страница 5: ...xternal Power Supply 12 VDC 0 5 A max Extron P N 28 331 57LF NOTE IPL Pro Series control processors accept power over Ethernet PoE through the LAN port in addition to network communication see Control LAN Ethernet on page 6 for cabling and details Both an external power supply and PoE can be connected to the control processor simultaneously The IPL uses PoE when it is available but can switch seam...

Страница 6: ... Control LAN Ethernet 1000 LINK ACT LAN PoE I IPL PR PRO S6 5 A6 XX XX XX E 5 A6 XX XX XX Rear Panel Front Panel RJ 45 Connector Insert Twisted Pair Wires Pins 1 2 3 4 5 6 7 8 1000 Mbps Connection Network is active Data is being sent received Link LED Activity LED LAN PoE Ethernet Default protocol IPL IP address 192 168 254 250 Gateway IP address 0 0 0 0 Subnet mask 255 255 255 0 DNS address 127 0...

Страница 7: ...input Each port senses external switch or contact closure by using a 1k ohm pull up resistor in a TTL 5 VDC circuit Use these ports to monitor or trigger events and functions toggle relays issue commands send e mail once configured Input LEDs Light when the corresponding ports are active tied to ground logic low Rear Panel Front Panel Switches sensors relays or similar items Share the same ground ...

Страница 8: ...rmware version 3 0 or higher By default DHCP is off and the unit uses a static IP address When you disable the DHCP client the unit reverts to using the previously set static IP address Reset All IP Settings Press and hold the front panel Reset button for 6 seconds After the Power LED blinks twice release and momentarily press the Reset button Use this mode to reset all network settings to factory...

Страница 9: ... a link for contacting an Extron support representative who can provide you access to the latest version To obtain Extron control product software you must have an Extron Insider account Extron provides training to our customers on how to use the software Access to the full features of Global Configurator Professional is available to users who successfully complete Extron Control Professional Cert...

Страница 10: ...schedules timers macros and local variables Add touchpanels or other interfaces if used to the project Configure ports on the control processor Import GUI layouts and configure the touchpanels or other interfaces Test the system make adjustments finalize configuration Save the project Build and upload the configuration to the control processor If desired or required install a new security certific...

Отзывы: