Symbol Definitions
]
= CR/LF (carriage line feed) (hex
0D
0A
)
}
= Soft carriage return (no line feed, hex
0D
)
(For web browser commands, use the
|
[pipe] character instead of the soft return.)
|
= Pipe (vertical bar) character
•
= Space
24
= The
24
superscript indicates commands that give an
E24
(privilege violation) message if you are not logged in at the
administrator level.
E
=
Escape key (hex
1B
) (For web browsers, use
W
instead of
E
. )
X!
= Power receptacle (
1-4
)
X#
=
Greenwich Mean Time (GMT) offset value
(-12.00 to +14.00) represents the time difference in hours and minutes (±
hh
:
mm
) relative to Greenwich, England. The
plus sign and leading zero are optional. For example, 5:30 =
+05:30
.)
X%
= On or Off status
0
= off or disable
1
= on or enable
X^
= Dirty memory status
1
= RAM needs to be saved to flash memory.
0
= RAM has been saved to flash (OK to power off or reset)
.
X(
= Current threshold sense
0
= clear or none
1
= standby
2
= full
(Full threshold must be set before standby.)
X1)
=
Group number
0
= none
1
= yellow
2
= green
3
= red
(The exponent designates the port number. The color relates to setting groups via the front panel.)
X1!
=
Version (typically listed to two decimal places, that is,
n.nn)
X1@
=
Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (
A-Z
), digits (
0-9
),
and minus sign or hyphen (
-
). No blank or space characters are permitted as part of a name. No distinction is made
between upper and lower case.
NOTE:
The first character must be a letter. The last character must not be a minus sign or hyphen.
X1#
= Local date and time format
Set format (
MM/DD/YY-HH:MM:SS
).
Example:
11/18/03-10:54:00
.
Read format (day of week, day month year
HH:MM:SS
).
Example:
Tue,
18
Nov
2011
18:19:33
.
X1$
= IP address (
nnn.nnn.nnn.nnn
)
. Leading zeros in each of four fields are optional in setting values, and they are
suppressed in returned values.
X1%
=
E-mail domain name (for example:
extron.com
)
X1^
=
Power-up delay between ports in 1/3-second increments.
1-255
permitted.
(Default is
3
, which equals 1 second.)
IPL T PC1 • SIS Programming and Control
50