11
©2001 - INLINE, Inc.
CIA116 Operation Manual - V1.3 01/03/01
Required Accessories (Ordered Separately)
Input and Local Monitor Adapter and Extension Cables:
VGA: IN8000 Series 15-pin HD male to 15-pin HD female, various lengths from 3’ to 100’
For Other Computers: Refer to the table on page 5
Optional Accessories
Audio Input Cables:
IN9106: 3.5mm stereo mini male to 3.5mm stereo mini male, 6’ long
IN9107: (1) 3.5mm stereo mini male to (2) RCA male, 6’ long
Installation Hardware:
IN9253: Flush-mount brackets - For Mounting CIA116 through Hole in Table Top
IN9254: Rack Ears - Rack Mounts Unit in 1 U Rack Space, Rack Ear Holds Up to
4 Additional Single-Space A/V Connector Modules
IN9255: Rack Ears - Rack Mounts Unit in 1 U Rack Space
RGB Installation Cables
Coaxial Cables
3-Conductor
4-Conductor
5-Conductor
Standard Resolution
IN7000-4
IN7000-5
Standard Resolution, Plenum
IN7000P-4
IN7000P-5
Super High Resolution
IN7300-3 IN7300-4 IN7300-5
Super High Resolution, Plenum
IN7400P-5
Ultra High Resolution
IN7200-3 IN7200-5 IN7200-6
All cable grades are available in lengths from 3’ to 250’ pre-terminated with high quality BNC connectors or as bulk cable.
Troubleshooting
Problem: The display device connected to the CIA116 output has a bad / scrambled image.
Solution 1: Verify that the correct input cable is being used (see the table on page 5).
Solution 2: The display device connected to the output of the interface may not be
compatible with the computer output. PC, MAC, SUN and other high-resolution
workstations have new and ultra high-resolution modes such as 1600 x 1200 and
1800 x 1440, and can output a video signal with a horizontal scan rate of over 100 KHz!
Many data monitors and data projectors are not compatible with these resolutions and
frequencies.
Solution 3: Check the dipswitch settings to make sure the unit is putting out a sync
format that the display device can use. For most applications, the default dipswitch
settings will work best (see page 9). For LCD / DMD / D-ILA / Plasma Display devices,
you may have to disable the horizontal position control.
Solution 4: The RGBS or RGBHV cable may have a bad sync line. Try running the sync
through another cable.