![Extron electronics IN1604 DT Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/extron-electronics/in1604-dt/in1604-dt_user-manual_2457038047.webp)
IN1604 DTP and IN1604 HD Scalers • SIS Configuration and Control
41
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Output Configuration Commands
TMDS output format
Set format
EX3$
VTPO
}
Vtpo
X3$]
Set the color space and format of the
output to
X3$
.
View setting
E
VTPO
}
X3$]
Vtpo
X3$]
View the color space and format setting.
Verbose mode 2 and 3
View auto output format
E
1*VTPO
}
X3$]
View the Auto output color space.
Power Save mode
Power Save off
E
0PSAV
}
Psav0
]
Operate at full power.
Power Save on
E
1PSAV
}
Psav1
]
Operate in a low power state. There is
no video output or DTP communication.
NOTE:
It may take some time for DTP communication to resume after Power Save mode is turned off.
View setting
E
PSAV
}
X4@]
View the Power Save mode.
Screen saver
Set mode
E
M
X2*
SSAV
}
SsavM
X2*]
Set the color of the screen saver to
X2*
.
View mode
E
MSSAV
}
X2*]
SsavM
X2*]
View the color of the screen saver.
Verbose mode 2 and 3
Set time-out duration
E
T
X2@
SSAV
}
SsavT
X2@]
Set the time-out duration to
X2@
.
View time-out duration
E
TSSAV
}
X2@]
SsavT
X2@]
View the time-out duration.
Verbose mode 2 and 3
View screen saver status
E
SSSAV
}
X4#]
SsavS
X4#]
View the screen saver status.
Verbose mode 2 and 3
NOTES:
X2@
= Output sync timeout
0
= OSD is never displayed, output sync is instantly
disabled with no active input
1-500
(in 1 second increments)
501
= output sync never times out
X2*
= Screen saver mode
1
= black output (default)
2
= blue output
X3$
= HDMI output format
0
= auto (default)
1
= DVI RGB 444
2
= HDMI RGB “Full”
3
= HDMI RGB “Limited”
4
= HDMI YUV 444 “Full”
5
= HDMI YUV 444 “Limited”
6
= HDMI YUV 422 “Full”
7
= HDMI YUV 422 “Limited”
X4@
= Power Save mode
0
= full power mode (default)
1
= low power state
X4#
= Screen saver status
0
= active input detected, timer not running
1
= no active input, timer running, output sync enabled
2
= no active input, timer expired, output sync disabled