Extron electronics HFX 100 Rx Скачать руководство пользователя страница 5

 

68-2260-01 Rev. C

1

2

 13

Extron Headquarters

+800.633.9876 Inside USA/Canada Only

 
Extron USA - West 

Extron USA - East

+1.714.491.1500 +1.919.

850.1000

+1.714.491.1517 FAX 

+1.919.

850.1001

 FAX

Extron Europe

+800.3987.6673
Inside Europe Only

+31.33.453.4040
+31.33.453.4050 FAX

Extron Asia

+65.6383.4400
+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656 FAX

Extron China

+86.21.3760.1568
+86.21.3760.1566 FAX

Extron Middle East

+971.4.299.1800
+971.4.299.1880 FAX

Extron Korea

+82.2.3444.1571
+82.2.3444.1575 FAX

Extron India

1800.3070.3777
(Inside India Only)

+91.80.3055.3777
+91.80.3055.3737  FAX  

© 

2013 Extron Electronics   All rights reserved.  All trademarks mentioned are the property of their respective owners. 

 

www.extron.com

HFX 100 Tx and HFX 100 Rx • User Guide

Mounting

Desktop Placement

Attach the four provided rubber feet to the bottom of the HFX 100 transmitter or receiver and place it in any convenient location.

Rack Mounting

UL guidelines for rack mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of these products in a rack:

Elevated operating ambient temperature

 — If the units are installed in a closed or multi-unit rack assembly, the operating 

ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the equipment in an 
environment compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C) specified by Extron.

Reduced air flow

 — Install the equipment in the rack so that the equipment gets adequate air flow for safe operation.

Mechanical loading

 — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.

Circuit overloading

 — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on 

overcurrent protection and supply wiring. Consider the equipment nameplate ratings when addressing this concern.

Reliable earthing (grounding)

 — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply 

connections other than direct connections to the branch circuit (such as the use of power strips).

Rack mounting procedure

To mount the unit on a rack shelf, follow the instructions provided with the shelf accessories.

Содержание HFX 100 Rx

Страница 1: ...1 LASER PRODUCT Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 5 dated June 24 2007 The product is intended to be used with the fiber optic cables fully installed This product meets the applicable requirements of IEC 60825 1 Edition 1 2007 Any service to this product must be carried out by Extron Electronics and its qualified service pe...

Страница 2: ...USB Extron HFX 100 Tx Transmitter Extron HFX 100 Rx Receiver Blu ray Player HDMI HDMI Flat Panel Display Up to 300m 984 ft on Multimode Fiber Figure 1 Typical HFX 100 Application Product Label DFX HFX 100 Series 33 2458 02 Rev A www extron com About Extron Electronics 1025 East Ball Road Anaheim CA 92805 Class 1 Laser Product 21 CFR 1040 10 This label is affixed to the bottom of the unit ...

Страница 3: ...n air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicated closet podium or desk The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadia...

Страница 4: ...sible radiation exposure Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure When the HFX 100 Rx is receiving optical input the front panel LED lights green Installation To install the HFX 100 extender follow these instructions 1 Mount the HFX 100 Tx and HFX 100 Rx in suitable locations see page 5 2 Connect the pr...

Страница 5: ...elevant to the safe installation of these products in a rack Elevated operating ambient temperature If the units are installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extr...

Отзывы: