2
FOX3 T/R 301 and FOX3 T/R 311 • Setup Guide (Continued)
g.
Connect peripheral devices to the USB ports (see figure 3).
NOTES:
•
The FOX3 matrix switches the USB HID and USB 2.0 inputs and outputs independently of the video and each USB
connection.
•
The USB 2.0 port is only available on the FOX3 T/R 301 devices.
•
The USB HID ports are used only for a mouse or keyboard.
•
The USB 2.0 ports are used for thumb drives, cameras, keyboards, a mouse, CAC reader, and such devices.
Transmitter
Receiver
60-60 Hz
100-240V
~
0.7A MAX
L
R
L
R
RS-232
Tx Rx
Tx Rx
G
IR
A
OUT
R
IN
OUTPUTS
AUDI
O
RETURN
INPUTS
CONTRO
L
B
OUT IN
USB 2.0
AUDIO
FO
X3 R 301
LAN
1
1
2
HDMI
DEVICES
USB HID
100 mA
500 mA
REMOTE
RS-232
Tx Rx
S 5V
G
3D
SYNC
60-60 Hz
100-240V
~
0.7A MAX
L
R
L
R
RS-232
Tx Rx
Tx Rx
G
IR
A
OUT
R
IN
INPUTS
AUDI
O
RETURN
OUTPUTS
CONTRO
L
B
OUT IN
HDMI
LOOP OUT
USB HID
USB 2.0
AUDIO
FO
X3
T 301
LAN
HOST
HOST
REMOTE
RS-232
Tx Rx
S 5V
G
3D
SYNC
SM or MM cable
USB
USB
USB
USB
USB
Laptop
L
t
Keyboard
y
Mouse
Thumb Drive
A
A
A
B
B
B
Figure 3.
Peripheral USB Connections Diagram
•
USB Host ports
(
A
) — Connect a USB type A to B cable between this USB type B port and the USB port of a host.
•
USB Hub ports
(
B
) — Connect a USB type A cable between the USB type A port and peripherals.
Step 3 — Control Connections
a.
To pass serial, IR data, or control signals, such as for serial control of a projector,
connect the master device to the transmitter and the controlled device to the
receiver via the CONTROL 5-pole captive screw connector (see figure 4 for
wiring).
NOTE:
For returned RS-232 and IR responses (from the receiver to the
transmitter) install the receiver-Tx-to-transmitter-Rx cable in
b.
For stereoscopic 3D sync such as an external IR emitter for glasses, connect a PC
to the two right poles of the REMOTE RS-232/3D Sync 5-pole captive screw port
on the transmitter (see
Tx
Rx
Rx
Tx
Gnd
Gnd
IR Device
RS-232 Device
Rx
Tx
Rx
Tx
G
RS-232
IR
CONTROL
Figure 4.
RS-232 and IR Wiring
Connect a display or projector to the two right poles of the REMOTE RS-232/3D Sync 5-pole captive screw port on the
receiver (
c.
For remote control of a unit and loading firmware (LAN or USB only), connect a host device, such as a computer or control
system, to one of the following ports (see the
FOX3 T/R 301 and FOX3 T/R 311 User Guide
, available at
www.extron.com
,
for details):
•
Remote RS-232 port
— Connect the 3 left poles of this 5-pole captive screw connector to this port (
The protocol for the Remote port is as follows:
•
9600 baud
•
no parity
•
8 data bits
•
1 stop bit
•
no flow control
•
LAN Ethernet port
— Connect an RJ-45 connector to this port (
).
•
USB Configuration port
— Connect a USB mini-B connector to this port (see
3
4