Extron electronics FOX 3G HD-SDI Скачать руководство пользователя страница 19

FOX 3G HD-SDI • Unit Mounting

11

Unit Mounting

Mounting the Transceiver

ATTENTION:

• 

Installation and service must be performed by authorized personnel only

.

• 

L’installation et l’entretien doivent être effectués par le personnel autorisé 
uniquement.

The 1-inch high, quarter rack width FOX 3G HD-SDI can be placed on a tabletop. It can 
also be mounted on any of mounted in any of the following ways:

• 

On a rack shelf 

• 

Through a desk or tabletop

• 

Under a desk or tabletop 

• 

On a projector bracket

Tabletop Use

Affix the included rubber feet to the bottom of the unit and place it in any convenient location.

Mounting Kit

Mount the unit using any compatible rack, furniture, or projector mounting kit, listed on the 
Extron website (

www.extron.com

), in accordance with the directions included with the kit. 

For rack shelf mounting, also see “UL Rack-Mounting Guidelines.”.

UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the installation of the 
FOX 3G HD-SDI into a rack.

• 

Elevated operating ambient

 — If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack environment may be greater than room 
ambient. Therefore, consider installing the equipment in an environment compatible with 
the +122 °F (+50 °C) maximum ambient temperature (Tma) specified by Extron.

• 

Reduced air flow

 — Installation of the equipment in a rack should be such that the 

amount of air flow required for safe operation of the equipment is not compromised.

• 

Mechanical loading

 — Mounting of the equipment in the rack should be such that a 

hazardous condition is not achieved due to uneven mechanical loading.

• 

Circuit overloading

 — Consideration should be given to the connection of the 

equipment to the supply circuit and the effect that overloading of the circuits might have 
on overcurrent protection and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this concern.

• 

Reliable earthing (grounding)

 — Reliable earthing of rack-mounted equipment 

should be maintained. Particular attention should be given to supply connections other 
than direct connections to the branch circuit (such as the use of power strips).

Содержание FOX 3G HD-SDI

Страница 1: ...User Guide FOX 3G HD SDI Fiber Optic Transceivers Multi Rate HD SDI SDI Fiber Optic Transceiver 68 1384 01 Rev C 10 17...

Страница 2: ...encia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur...

Страница 3: ...ey Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVault PowerCage PURE3 Quantum SoundField SpeedMount SpeedSwitch System INTEGRATOR TeamWork TouchLink V Lock VoiceLift VN Matrix W...

Страница 4: ...o this product must be carried out by Extron Electronics and its qualified service personnel CAUTION Using controls making adjustments or performing procedures in a manner other than what is specified...

Страница 5: ...rt CAUTION Risk of minor personal injury ATTENTION Risque de blessure mineure ATTENTION Risk of property damage Risque de dommages mat riels NOTE A note draws attention to important information Specif...

Страница 6: ......

Страница 7: ...ut this Manual 2 About the FOX 3G HD SDI 2 Transceiver Configurations 2 Features 4 Installation and Operation 6 Installation Overview 6 Connections and Settings 6 Operation 10 Front Panel Indicators 1...

Страница 8: ...FOX 3G HD SDI Contents viii...

Страница 9: ...tic cable is unplugged AVERTISSEMENT Le FOX 3G HD SDI met une lumi re invisible en continu conforme la classe 1 qui peut tre dangereux pour les yeux utiliser avec pr caution Ne regardez pas dans les c...

Страница 10: ...itor Video Editor OVER RANGE STATUS OPERATE OPTION B OPTION A OVER RANGE STATUS OPERATE OPTION B OPTION A Figure 1 Typical FOX 3G HD SDI Application NOTE The three products are physically and function...

Страница 11: ...nother FOX 3G HD SDI that is configured as either a bidirectional transceiver or a receiver 12V 0 3A MAX FOX HDSDI HD SDI IN POWER BUFFERED OUTPUTS MODE OPTICAL Rx Tx 1 2 12V 0 3A MAX FOX HDSDI HD SDI...

Страница 12: ...iver converts the proprietary signal back to original HD SDI SDI or 3G SDI video and outputs the video on only one of its own Buffered Output BNC connectors Output 2 The receiver converts the second d...

Страница 13: ...ls and reshapes and restores signals on its buffered outputs Daisy chain capability Up to 3 transceivers can be daisy chained to send the video to multiple locations when one of more units are configu...

Страница 14: ...that the video sources and the output display are all turned off and disconnected from the power source 2 Mount the transceivers See Mounting the Transceiver on page 11 3 Connect the cables and config...

Страница 15: ...s de c ble fibre optique sur le panneau arri re ou dans les c bles fibre optique eux m mes Branchez les protections contre la poussi re dans l ensemble metteur r cepteur lorsque le c ble fibre optique...

Страница 16: ...gure 5 shows how to wire the power connector Use the supplied tie wrap to strap the power cord to the extended tail of the connector Power Supply Output Cord Captive Screw Connector SECTION A A Ridges...

Страница 17: ...oltage polarity can damage the power supply and the unit The ridges on the side of the cord figure 5 on the previous page identify the power cord negative lead ATTENTION Si le produit n est pas fourni...

Страница 18: ...the Rate Unknown LED lights this indicates that an input is detected either on the HD SDI input BNC if configured as a transmitter or on the Optical Rx connector if configured as a receiver or bidire...

Страница 19: ...ack Elevated operating ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consider instal...

Страница 20: ...pe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg...

Отзывы: