background image

EDID 101D/EDID 101V • Installation and Operation

Installation and Operation, cont’d

10

EDID 101D/EDID 101V Operation

The EDID 101 can either record EDID from a display device or a 

pre-programmed EDID can be selected using the rotary and DIP 

switches.  

Recording a display EDID

To record a new EDID into memory: 

Turn the rotary switch (

1. 

d

) to position 0.  

N

 

The DIP switch positions have no effect in this mode.  

Apply power to the EDID 101 by connecting a power 

2. 

source.

N

 

If power is not available from a video source, an external 

12 VDC power supply can be used.  The green LED will 

be lit when power is available.

Connect the display device to the 

3. 

OutPut

 of the 

EDID 101 using a DVI (EDID 101D) or a VGA (EDID 101V) 

cable.  

N

 

To capture analog EDID on the EDID 101D, a DVI-A to 

VGA adapter must be used.

Power on the display device.

4. 

N

 

Although the EDID 101 supplies 5 VDC to power the 

EDID circuitry of a display device, power on the display 

device to ensure that data is being transmitted during 

the recording process.

Press and hold the recessed record button (

5. 

b

) until the 

LED flashes red rapidly, then release the button.  The LED 

continues to flash red, then returns to solid green when 

the EDID data has been stored.  The display can now be 

disconnected.

N

 

If an external supply was used for recording, it can now 

be disconnected.  

Install the EDID 101 into the system. 

6. 

 

Содержание EDID 101D

Страница 1: ...User s Manual EDID 101D EDID 101V EDID Emulator with EDID Minder 68 1773 01 Rev A 06 09 ...

Страница 2: ...faufmerksam machen daß im Inneren des Gehäuses dieses ProduktesgefährlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen können herrschen Achtung Lesen der Anleitungen Bevor Sie das Gerät zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit ...

Страница 3: ...d including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio commun...

Страница 4: ...delines for rack mounting 5 Rack mounting procedures 6 Furniture mounting 7 Panel Features 8 Side panel 8 Front and rear panels 9 EDID 101D EDID 101V Operation 10 Recording a display EDID 10 Using the pre programmed Extron EDID 11 Specifications 12 Included Parts 14 Accessories 14 All trademarks mentioned in this manual are the properties of their respective owners 68 1773 01 Rev A 06 09 ...

Страница 5: ...Identification Data A source device normally uses EDID to identify the signal type i e analog or digital the native rate of the display how to correctly output the preferred native timing additional rates supported by the display and various other information The Extron EDID 101 is a standalone EDID Minder device that emulates EDID to a DVI or VGA source It helps ensure the video source boots up c...

Страница 6: ...by the video source N Configuring the EDID 101 rotary and DIP switches allow a user to select a pre programmed EDID based on the native rate of a display i e 1280x1024 60 Hz and a desired signal type i e digital but does not necessarily force a video source to output that rate Since EDID is not limited to reporting a single video rate i e the native rate each Extron EDID also lists other common vi...

Страница 7: ...OURCE DVI OUTPUT DISPLAY D SUB NPUT SOURCE D SUB OUTPUT DISPLAY DVI DVI Mac Mini DVI DVI DVI DVI EDID 101D Projector EDID 101D EDID to PC No EDID Passed EDID 101V PC VGA VGA Twisted Pair VGA VGA VGA VGA Projector EDID 101V MTP 15 HD A D MTP RL 15 HD RS RGB PEAKING LEVEL MTP SERIES Typical EDID 101 applications ...

Страница 8: ...HER IR IN1508 PICTURE CONTROL VGA SVGA XGA SXGA ON 7 6 5 4 3 2 1 SWAP 8 CENTER SIZE CONT BRT COL TNT MENU ENTER 1024x852 1024x1024 1366x768 1365x1024 UXGA 720p 1080i 1080p RS 232 AU DIO INP UT S AU DIO OU TP UT S L R L R L R 1 2 1 3 4 2 1 5A MAX R 1 2 G B H V R G B H V INP UT S OU TP UT S R G B H V 100 240V 50 6 0Hz 3 4 1 2 H VH V H VH V 1 ON 2 3 4 Projector Extron Crosspoint 300 42 HVA Wideband M...

Страница 9: ...g ambient temperature If the unit is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in the rack so the equipment gets ad...

Страница 10: ...ucts part 60 604 10 RSU 129 universal rack shelf kit for 9 5 deep products part 60 190 01 RSB 129 basic rack shelf kit for 9 5 deep products part 60 604 01 To rack mount the EDID 101D EDID 101V 1 If necessary remove the rubber feet 2 Secure the EDID 101 to the shelf with two 4 40 x 3 16 screws in opposite corners of the base see below 3 Install false faceplate s or other unit s to the rack shelf 4...

Страница 11: ...at the marked screw locations 4 Insert 8 wood screws into the four pilot holes Tighten each screw into the mounting surface until just less than 1 4 of the screw head protrudes 5 Align the mounting screws with the slots in the brackets and place the EDID 101 and brackets against the surface with the screws through the bracket slots 6 Slide the EDID 101 slightly forward or back then tighten all fou...

Страница 12: ...ammable memory position 0 on the rotary switch c DIP switch Position 1 is used to select the vertical refresh frequency for the pre programmed EDID When switched to Off the EDID selected by rotary positions 1 through F are based on 50 Hz When switched to On they are based on 60 Hz default position Position 2 not used on EDID 101V labeled Spare selects the signal format digital or analog for the pr...

Страница 13: ...DID 101 is powered from a video source there is no need to connect an external power supply f Input connector EDID 101D Female DVI I EDID 101V Female D Sub 15 pin g Output connector EDID 101D Female DVI I EDID 101V Female D Sub 15 pin N DVI A to VGA adapters may be used to connect the EDID 101D to analog displays and sources having VGA connectors EDID functionality if the VGA source supports it wi...

Страница 14: ... lit when power is available Connect the display device to the 3 output of the EDID 101 using a DVI EDID 101D or a VGA EDID 101V cable N To capture analog EDID on the EDID 101D a DVI A to VGA adapter must be used Power on the display device 4 N Although the EDID 101 supplies 5 VDC to power the EDID circuitry of a display device power on the display device to ensure that data is being transmitted d...

Страница 15: ...set the rotary switch 2 d to the position 1 F selected in step 1 The switch clicks as it moves through the positions Rotary Switch Position Resolution 0 User Recorded EDID 1 800x600 2 1024x768 3 1280x720 4 1280x768 5 1280x800 6 1280x1024 7 1360x768 8 1366x768 9 1400x1050 A 1440x900 B 1600x1200 C 1680x1050 D 1920x1080 E 1920x1200 F Digital Dual Link DVI Analog Not Used Table 1 Rotary Switch positio...

Страница 16: ...t EDID 101D digital signals Number signal type 1 dual or single link DVI D Connectors 1 female DVI I Video EDID 101D analog signals EDID 101V Bandwidth 350 MHz 3dB Gain Unity Video input EDID 101D analog signals EDID 101V Number signal type 1 analog VGA UXGA RGBHV RGBS RGsB RsGsBs Connector 1 female 15 pin HD Nominal level 0 7 Vp p for RGB Minimum maximum levels Analog 0 3 V to 1 5 Vp p with no of...

Страница 17: ...0 C 10 to 90 noncondensing Cooling Convection no vents Mounting Rack mount Yes with optional 1U rack shelf Enclosure type Metal Enclosure dimensions 1 0 H x 2 2 W x 3 0 D one eighth rack wide 2 5 cm H x 5 6 cm W x 7 6 cm D Product weight 0 4 lbs 0 2 kg Shipping weight 2 lbs 1 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE c UL UL EMI EMC CE C ...

Страница 18: ...PS 1210C 12 VDC 1 A power supply 70 775 01 RSU 129 universal rack shelf kit for 9 5 deep products gray 60 190 01 RSB 129 basic rack shelf kit for 9 5 deep products black gray 60 604 01 02 RSU 126 universal rack shelf kit for 6 deep products 60 190 10 RSB 126 basic rack shelf kit for 6 deep products 60 604 11 RSF 123 rack shelf kit for 3 5 deep products with faceplates 60 190 20 RSB 123 basic rack ...

Страница 19: ...Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 383 4400 Asia o...

Страница 20: ...USA Canada Only 1 919 863 1794 1 919 863 1797 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 2991800 971 4 2991880 FAX ...