3
Installation
1.
Mount the DTP T DSW 4K unit in a suitable location (see the
Mounting
section of the
DTP T DSW 4K Series User Guide
for
mounting options). Follow the instructions provided with the mounting kit.
2.
Connect the USB or RS-232 connector (see
G
on the previous page) to a PC for configuration and maintenance. Use SIS
commands or the Extron PCS program to configure EDID Minder, mute the video signal, mute the audio signal, adjust the
video color bit depth, or monitor the signal and HDCP status, as required (see the
DTP T DSW 4K Series User Guide
for more
information)
.
3.
Connect the rear panel transmitter output (see
D
on the previous page) to a rear panel receiver input using shielded twisted
pair (STP) cable.
NOTES:
•
The DTP T DSW 4K 233 can transmit video, control, and audio (if applicable) signals up to 230 feet (70 meters).
•
The DTP T DSW 4K 333 can transmit video, control, and audio (if applicable) signals up to 330 feet (100 meters).
For optimal performance, Extron highly recommends the following:
•
RJ-45 termination with STP cable must comply with TIA/EIA-T568B wiring standard for all connections. For more
information on cable wiring and termination, see the full product user guide at
www.extron.com
.
•
Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.
ATTENTION:
•
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.
•
N’utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d’Extron ou le câble STP201.
•
Use shielded RJ-45 plugs to terminate the cable.
•
Overall transmission distance capabilities vary depending on the number of patches used. If possible, limit the number of
patches to 2 total.
•
If RJ-45 patches must be used in the system, Extron recommends shielded CAT 6 (or better) patches.
4.
Connect control devices.
a.
Connect contact closure devices or Extron “Show Me” cables to the Contact In 4-pole captive screw connector (see
G
on the previous page).
b.
Connect tally devices or Extron “Show Me” cables to the Tally Out 4-pole captive screw connector (see
G
on the
previous page).
c.
For serial RS-232 control, connect a host device to the RS-232 3-pole captive screw connector (see
F
on the previous
page) or the 3-pole captive screw connector (see
G
on the previous page).
d.
For control or configuration through USB, connect a host device to the front panel USB mini-B port (see
B
on page 1).
5.
Connect and power on related devices to the switcher and compatible receivers.
6.
At the power outlet, connect the power supply to power on the unit (see the
DTP T DSW 4K Series User Guide
for information
on power connector wiring and remote power).