Extron electronics DMP 128 Plus Скачать руководство пользователя страница 4

Extron Headquarters

+800.633.9876 Inside USA/Canada Only

 
Extron USA - West 

Extron USA - East

+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX 

+1.919.850.1001 FAX

Extron Europe

+800.3987.6673
Inside Europe Only

+31.33.453.4040
+31.33.453.4050 FAX

Extron Asia

+65.6383.4400
+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656 FAX

Extron China

+86.21.3760.1568
+86.21.3760.1566 FAX

Extron Middle East

+971.4.299.1800
+971.4.299.1880 FAX

Extron Australia

+61.8.8113.6800
+61.8.8351.2511 FAX

Extron India

1800.3070.3777
(Inside India Only)

+91.80.3055.3777
+91.80.3055.3737  FAX  

© 

2017 Extron Electronics   All rights reserved.  All trademarks mentioned are the property of their respective owners. 

 

www.extron.com

Configure Dante Device Settings (AT Models Only):

Dante settings on DMP 128 Plus AT models can be configured from DSP Configurator. The Dante device can be named here, 
which aids in device identification in the Dante Controller software when there are multiple Dante devices on the audio network.

ATTENTION:

 It is essential that a Dante device be named before audio subscriptions with other devices are 

established. Existing subscriptions are removed when a device is renamed.

To configure Dante device settings:

1. 

Open DSP Configurator and connect Live to the DMP 128 Plus AT (see step 3b on the previous page).

2. 

Select 

Tools>Device Settings

. The 

Device Settings

 dialog box opens.

3. 

From the tabs at the top of the 

Device Settings

 dialog box, select 

Dante 

Device

.

a. 

It may be necessary to use the right navigation arrow (

) at the top right 

corner of the 

Device Settings

 dialog box to navigate to the 

Dante 

Device

 tab (see figure to the right).

4. 

In the 

Device name

 field, give the DMP 128 Plus AT a meaningful name 

(such as device model and location) so that it can be easily identified in 
Dante Controller.

5. 

Dante device network settings can also be configured from this dialog box. 
Use the radio buttons and text fields to choose 

DHCP

 (recommended) or 

Static IP

 and enter a static IP address configuration.

NOTE:

  The device name and IP configuration in the 

Dante Device

 tab 

only affect the Dante interface of the DMP 128 Plus AT. These settings 
do not affect the device name recognized in DSP Configurator or the IP 
address of the rear panel LAN port.

6. 

Select 

Enable Redundant Mode

 only if configuring the DMP 128 Plus AT 

for use on redundant networks. A separate set of redundancy network settings opens for configuration (see 

Physical Dante 

Network Setup

 in the 

DMP 128 Plus User Guide

 for more information on redundant configuration).

7. 

Click 

Apply

.

8. 

Click 

OK

 to confirm changes and close the 

Device Settings

 dialog box.

For more information on configuring a DMP 128 Plus AT model in Dante Controller, refer to the 

Dante Controller

 section of the 

DMP 128 Plus User Guide

 (

www.extron.com

).

 

68-2826-50 Rev. C 

07 17