Extron electronics Control Panel CTL208CM Скачать руководство пользователя страница 8

CTL208CM Control Panel Module • Installation

CTL208CM Control Panel Module • Installation

Installation, cont’d

9

Program the control panel module’s buttons as desired,
using either the Extron ICS100 control software or the
Extron serial character command set.  See 

ICS100 Windows

Control Program

 and/or 

Serial Commands

 in chapter 4, 

Serial

Communications

, for details.

10

If necessary, configure the control panel module’s serial
control protocol settings (baud rate, data bits, and stop
bits) to match those of the device to be controlled.  See

ICS100 Windows Control Program

 and/or 

Serial Commands

in chapter 4, 

Serial Communications

, for details.

11

If necessary, reconfigure the control panel module’s rear
panel DIP switch 1 to match the serial protocol (RS-232,
RS-422, RS-485) of the device to be controlled.  See 

Rear

Panel Setup

, in this chapter for details.

12

If the computer, control panel module, and the device to
be controlled are not part of an RS-485 serial port daisy
chain, disconnect the serial control cable from the
computer and install the serial control cable between the
control panel module and the device to be controlled.

If the rear of the control panel module will be inaccessible
when the installation is complete, the operation of the
module should be tested before the final mounting.

13

Apply or connect power to all devices in the system.

14

Test the system: 

Ensure that the controlled device

responds as desired to the control panel module buttons.
If necessary, correct the programming and/or the system
wiring.  Ensure that you remove electrical power if you
need to change the system wiring.  Test the system again.

15

Disconnect power

 from the control panel module and

other devices.

16

Mount the control panel module into any Extron four-
space mini-AAP connector panel.

If the rear of the control panel module will be inaccessible
when the installation is complete, all cables, including
the power connector on the CTL208, must be connected
before the permanent installation.

17

Mount the mini-AAP connector panel to the mini-AAP
mounting option as necessary.  See 

Wall mounting

 in this

chapter for details about wall mounting the panel.

18

Restore power to all devices.

2-3

Installation Overview

CAUTION

Installation and service must be performed by
authorized personnel only.  UL Listed electrical
boxes are recommended.  See 

UL Requirements

for Wall Box Installation

 in this chapter.

1

If desired, order a custom engraved front panel.  Contact
the Extron S

3

 Sales & Technical Support Hotline to order

the panel.

2

Power off all devices and disconnect them from the
power source, if necessary.

3

Run a serial cable between the site where the CTL208CM
control panel module will be installed and the site of the
serial-controlled device.

4

For installation in a wall or furniture

, prepare the site:

cut a hole in the surface, install the electrical box or
mounting bracket, and prepare the cables.  See 

Wall

Mounting Site Preparation

 in this chapter.  See appendix A,

Reference Information

, for a partial list of devices that can

accept four space mini-AAPs.

5

For other installations

, install a tabletop or in-table

connector bay, or other mini-AAP mounting option.
Refer to the manual for the device in which the control
panel module will be installed.  See appendix A, 

Reference

Information

, for a partial list of devices that can accept four

space mini-AAPs.

6

Connect a serial cable between the control panel module
and a computer.  See 

Rear Panel Setup

, in this chapter for

details.

Alternatively, you can connect the control panel module
to an RS-485 serial port daisy chain that includes the
programming computer and the device to be controlled.
In a daisy-chain configuration, you can make changes to
the control panel module’s button programming as
needed, without removing the panel from its installation.

7

If necessary, configure the control panel module’s rear
panel DIP switches to match the serial protocol (RS-232,
RS-422, RS-485) of the computer used to program the
control panel module.  See 

Rear Panel Setup

, in this chapter

for details.

8

Connect the power source to the control panel module.
See 

Rear Panel Setup

, to wire the power connector.

Installation

2-2

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание Control Panel CTL208CM

Страница 1: ...PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2003 Extron Electronics All rights reserved 8 Button Control Panel Module with Serial Control Output 68 836 01 Rev A Printed in the USA 07 03 CTL208CM im Vertrieb von CAMBOARD Electr...

Страница 2: ...nur von qualifiziertem Servicepersonal durchgeführt werden Die internen Komponenten des Gerätes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Gerät selbst öffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und Öffnungen Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist die...

Страница 3: ...module s rear panel DIP switches Step 5 Connect a serial cable between the control panel module and a computer Step 6 Connect the external power supply to the control panel module Step 7 Program the control panel module s buttons as desired using either the Extron ICS100 control software or the Extron ASCII character command set Step 8 If necessary set the control panel module s serial control set...

Страница 4: ...gramming the CTL208 4 13 Table of Contents Step 10 If the rear of the control panel module will be inaccessible when the installation is complete the module should be powered up and its operation should be tested before the final installation Apply or connect power to all devices in the system Step 11 Test the system Ensure that the controlled device responds as desired to the control panel module...

Страница 5: ...ademarks mentioned in this manual are the properties of their respective owners Appendix Reference Information A 1 Specifications A 2 Parts List A 3 Included parts A 3 Mini AAP mounting options A 3 Wall mounting solutions A 3 Architectural solutions A 4 Table solutions A 4 Wall mounting hardware A 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camb...

Страница 6: ...I or hex string programmed to a button when you press that button The module sends the secondary string when you press the button a second time Button grouping Buttons that are in toggle mode can also be assigned to a group When one button is selected the control panel module deselects all other buttons in the group Button timeout Buttons that are in toggle mode can be further set to automatically...

Страница 7: ...odule 2 Chapter Two Installation Installation Overview UL Requirements for Wall Box Installation Wall Mounting Site Preparation DeviceConfiguration Wall Mounting Rear Panel Setup 1 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Страница 8: ...e mini AAP mounting option as necessary See Wall mounting in this chapter for details about wall mounting the panel 18 Restore power to all devices 2 3 Installation Overview CAUTION Installation and service must be performed by authorized personnel only UL Listed electrical boxes are recommended See UL Requirements for Wall Box Installation in this chapter 1 If desired order a custom engraved fron...

Страница 9: ...shield can be cut back to the point where the cable exits the cable clamp Both braided and foil shields should be connected to an equipment ground at the other end of the cable 2 5 2 4 UL Requirements for Wall Box Installation The following Underwriters Laboratories UL requirements pertain to the installation of the CTL208CM into a wall or furniture figure 2 1 2 5 Installation Cable Conduit Extron...

Страница 10: ...rt the wall box into the opening and attach it to the wall stud or furniture with nails or screws leaving the front edge flush with the outer wall or furniture surface figure 2 3 The illustration applies to both two gang and four gang wall boxes Wall opening flush with edge of box Installation Cable Cable Clamp Screws or Nails Wall Stud Figure 2 3 Attaching a wall box to a stud If attaching the wa...

Страница 11: ... 1 SERIAL MODE 0 RS232 2 3 TERMINATION 1 RS485 RS422 1 120 OHMS 0 OPEN END UNIT 4 RESERVED 5 FACTORY RESET 0 NORMAL SPARE 6 1 3 2 Figure 2 7 Rear panel view 2 9 2 8 Wall Mounting The physical orientation of the control panel module is important when you are programming and operating the buttons Buttons 1 and 5 figure 2 5 are on top when the CTL208 is right side up Orient the CTL208 so that the tex...

Страница 12: ...tch Function On 1 On 1 1 Serial mode RS 485 position RS 422 position 2 Rx termination On 1 or Off 0 On 1 or Off 0 On 1 if full duplex or Off 0 if half duplex 3 Tx termination Off 0 Off 0 Off 0 Off 0 RS 232 position If the CTL is the last unit in a daisy chain The default settings for all switches for an RS 232 connection is off 0 DIP switch 3 should be turned on for an RS 485 full duplex connectio...

Страница 13: ...on Installation cont d CTL208CM Control Panel Module 3 Chapter Three Operation ButtonModes Send Programmed Commands Factory Reset 2 12 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Страница 14: ...er set to automatically toggle off after a user defined period of time up to 255 minutes Timeouts cannot be assigned to buttons that are set to operate in groups Send Programmed Commands 5 6 7 8 1 Button number Button number 2 3 4 Figure 3 1 Power connector wiring The actions that occur when you push a programmed button vary depending on how the button is programmed Single mode Push the button to ...

Страница 15: ...curs on the full minute Thus the timeout can occur up to 59 seconds earlier than the number of minutes programmed Over the length of the average timeout setting this early timeout is considered of no consequence Factory Reset With power removed set rear panel DIP switch 5 to on up Reapply power Set switch 5 back to off down The DIP switch factory reset performs the following functions Resets the c...

Страница 16: ...he Browse button An open file window appears 3 Navigate to the drive or folder that contains the software 4 Double click the setup icon 5 Click Ok in the Run window 6 Click Ok in the InlineControl Setup window 7 Click the icon button in the next InlineControl Setup to install the software in the default Extron directory in the Program group If you want to specify a different directory click on the...

Страница 17: ...nel module can also take commands after receiving a broadcast address of 00 but it will not send responses Broadcast addressing is for multiple units on an RS 485 serial line in half duplex mode After you are finished sending commands to the control panel module always end the session by selecting a different address than the one assigned to the CTL208 This prevents the module from responding to c...

Страница 18: ...ss the button the CTL sends the hex value 6 In the Button Codes window figure 4 7 enter the desired primary code in the Code 1 window Codes that are intended to be hex codes must be in pairs Use a leading 0 if necessary Letters must be upper case Many common keyboard key codes which are often required for ASCII or hex control of another device are available in the selection buttons on the bottom o...

Страница 19: ... module s serial port is factory configured to 9600 baud no parity no flow control half duplex mode If you change the serial protocols communications between the computer and the control panel module are lost until the computer is updated to match the new control panel module settings The communications protocols of the control panel module should match the protocols of the device to be controlled...

Страница 20: ...y last command that you send to the control panel module should be the connect CC X1 command where X1 is a different address This prevents the control panel module from accepting and responding to commands for other devices X2 Button number and string primary or secondary figure 4 8 Buttons 1 and 5 are closest to the top of the CTL208 Orient the CTL208 so that the text on the rear of the unit is r...

Страница 21: ...ature Any character other than 0 is the character that will be replaced by a bracket or when the X3 code is saved to a CTL208 button X6 Hex button code Similar to the ASCII button code X3 with the addition of an ASCII to hex conversion before the value is stored For example if you send the ASCII value 0F the CTL converts it to the hex value 0F When you press the button the CTL sends 0F hex Entries...

Страница 22: ...t to default CPp R0 X1 CPp Reset the control panel module to its default serial port settings 9600 baud no parity Xoff and half duplex mode View serial port parameters CPp R0 X1 CPp X11 X12 X13 X14 Button code programming continued View a button s hex code PCHp X2 R0 X1 PCHp X2 X6 Reset button code ASCII or hex PCLp X2 R0 X1 PCLp X2 Clear any codes assigned to a button The CTL will not send any co...

Страница 23: ...l lockout FP R0 X1 FP Toggle front panel status enabled to disabled or disabled to enabled View front panel lockout FP R0 X1 FP X15 Enable disable responses Enable serial responses RES1 R0 X1 RES1 Control panel module sends responds to serial port commands Disable serial responses RES0 none Control panel module does not send responses to serial port commands Control panel module reset Reset contro...

Страница 24: ...rence Information A 2 Specifications Control remote Serial control port 1 RS 232 RS 422 or RS 485 5 pole captive screw connector Baud rate and protocol 1200 2400 4800 9600 default 19200 or 38400 baud 8 bit 1 stop bit no parity default even parity or odd parity half default fullduplex Pin configurations RS 232 3 TX 5 RX 1 Gnd RS 422 RS 485 3 TX 2 TX 5 RX 4 RX 1 GND Program control Extron s ICS100 c...

Страница 25: ...CIA112 2 CIA112 black without cable guards CIA112 3 CIA112 Inline white without cable guards CIA112 4 RGB 478 Mxi black 60 592 02 RGB 48 Mxi white 60 592 03 Table solutions Description Part number CPM208 1 Mini AAP bay 60 589 13 CPM212 1 Tabletop mini AAP bay black 60 590 11 CPM212 2 Tabletop mini AAP bay white 60 590 21 Wall mounting harware Description Part number One gang J box 2 5 deep 980130 ...

Отзывы: