2 Line up the bracket holes on the junction/gang box and ensure that they align. If the holes do not
align, drill new holes.
Note
When you line up the holes, the locking tab on the bracket must be pointing up and the
junction/gang box must be fully covered by the bracket. The bracket must be square to
the rest of the room walls and the two holes that are being used must be on the opposite
sides of large center hole on the bracket.
3 Using the holes aligned together or the new ones drilled, attach the bracket to the junction/gang
box using the screws removed from the box earlier.
4 Connect the LAN/Ethernet cable to the AP.
5
.
Mounting the AP to a Beam
The AP3915e access point can be mounted onto a beam using a beam clip accessory
(BRKT-000147A-01) to the main mounting bracket.
Pre-installation checklist:
•
The beam must be able to support the AP in all environmental conditions.
•
The beam should be flat.
Before attaching the AP onto a beam, verify that:
•
Beam attachment area is at least 0.5” (12.7mm) wide and as long as the AP’s largest dimension.
•
Beam mounting surface is less than 0.650” (16.5mm) thick.
To attach an AP to a beam, attach a beam clip (Accessory BRKT-000147A-01) to the main mounting
bracket:
Installation Process
ExtremeWireless™ AP3915e FCC/ROW Install Guide