background image

Installing the Virtual Services Platform
8000 Series

Release 6.1

NN47227-300

Issue 11.02

December 2017

Содержание Virtual Services Platform 8000 Series

Страница 1: ...Installing the Virtual Services Platform 8000 Series Release 6 1 NN47227 300 Issue 11 02 December 2017...

Страница 2: ...TERMS OF USE IF YOU ARE ACCEPTING THE TERMS OF USE ON BEHALF A COMPANY OR OTHER LEGAL ENTITY YOU REPRESENT THAT YOU HAVE THE AUTHORITY TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE SUCH...

Страница 3: ...TREME NETWORKS CHANNEL PARTNER IS RESPONSIBLE FOR ANY AND ALL RELATED FEES AND OR ROYALTIES THE G 729 CODEC IS LICENSED BY SIPRO LAB TELECOM INC SEE WWW SIPRO COM CONTACT HTML THE H 264 AVC CODEC IS L...

Страница 4: ...For additional information on Extreme Networks trademarks please see http www extremenetworks com company legal...

Страница 5: ...32 Electrostatic discharge 33 Technical specifications 34 Package contents 36 Installing the VSP 8000 Series in an equipment rack 37 Using the optional slide rack mount kit 38 Using the supplied brack...

Страница 6: ...port LED state indicators 87 Channelized LED state indicators 88 Enterprise Device Manager EDM representation of physical LED status 89 40GBASE QSFP ports 89 Chapter 6 Translations of safety messages...

Страница 7: ...ar from you We welcome all feedback but especially want to know about Content errors or confusing or conflicting information Ideas for improvements to our documentation so you can find the information...

Страница 8: ...eme Networks service contract number and or serial numbers for all involved Extreme Networks products A description of the failure A description of any action s already taken to resolve the problem A...

Страница 9: ...e added to or changed on the Avaya Support website About this task You can subscribe to different types of general notifications for example Product Correction Notices PCN which apply to any product o...

Страница 10: ...NS area click Add More Products 8 Scroll through the list and then select the product name 9 Select a release version 10 Select the check box next to the required documentation types Preface December...

Страница 11: ...11 Click Submit Subscribing to e notifications December 2017 Installing the VSP 8000 Series 11...

Страница 12: ...Chapter 2 New in this document There are no feature changes in this document December 2017 Installing the VSP 8000 Series 12...

Страница 13: ...01 E6 Note Replace the x with a country specific power cord code See the footnote for details VSP 8284XSQ DC This model number ships with one field replaceable 800 watt DC power supply Includes all of...

Страница 14: ...rd common in Austria Belgium Finland France Germany The Netherlands Norway and Sweden C Includes power cord commonly used in the United Kingdom and Ireland D Includes power cord commonly used in Japan...

Страница 15: ...ve components EC8400A01 E6GS VSP 8404 AC PS NA PC GSA This model number is also TAA compliant and ships with an AC power supply However it includes a North American power cord Includes all of the abov...

Страница 16: ...oper letter to indicate desired product nationalization See the following for details A No power cord included B Includes European Schuko power cord common in Austria Belgium Finland France Germany Th...

Страница 17: ...8408QQ TAA compliant Note Two ports are reserved for future use 8 port 40GBASE QSFP Ethernet Switch Module EC8404003 E6GS 8418XSQ 16 port 10GBASE SFP and 2 port 40GBASE QSFP Combination Ethernet Switc...

Страница 18: ...me up The switch logs the device as an unsupported or unknown device For more information about compatible transceivers see Installing Transceivers and Optical Components on VSP Operating System Softw...

Страница 19: ...nd cables Phillips 2 screwdriver RJ 45 console port cable ESD cable See Cable requirements for the VSP 8000 Series on page 71 4 Unpack the equipment Observe ESD precautions when you unpack the equipme...

Страница 20: ...No Task Description permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrode Preinstallation checklist December 2017 Installing the VSP 8000 Series 20...

Страница 21: ...optional slide rack mount kit on page 38 Using the supplied brackets on page 70 2 Install the primary or redundant power supply Important A combination of AC input and DC input power supplies in the s...

Страница 22: ...fer to the port below For a description of what the LEDs mean see SFP SFP QSFP and QSFP28 port LED state indicators on page 86 2 Eighty SFP ports that support 1G SFPs and 10G SFP s 40 ports in Slot 1...

Страница 23: ...1 4 from left to right and the power supplies are numbered PSU 1 on top and PSU 2 on the bottom Figure 2 VSP 8284XSQ Rear view VSP 8400 The VSP 8400 consists of four slots to install ESMs For more in...

Страница 24: ...on page 17 2 LEDs for system power PWR switch status Status redundant power supply RPS and fan modules Fan 3 USB port 4 Console port 5 OOB management port Ethernet Switch Module An Ethernet Switch Mo...

Страница 25: ...RU H 20 32cm W 29 21cm D Weight 4 05 lbs 1 84 kg Power and thermal 118 69W max 404 97 BTU hr Figure 5 8424XT 8408QQ 8408QQ EC8404003 E6 provides 8 40G QSFP ports 8408QQ GSA version EC8404003 E6GS 8 40...

Страница 26: ...4006 E6 16 1 10G Copper and 2 40G QSFP ports 8418XTQ GSA version EC8404006 E6GS 16 1 10G Copper and 2 40G QSFP ports Dimension 4 4cm 1RU H 20 32cm W 29 21cm D Weight 4 0 lbs 1 81 kg Power and thermal...

Страница 27: ...and thermal 12 62W max 47 90 BTU hr Figure 10 8424GT 8402CQ 8402CQ EC8404009 E6 2 100G QSFP28 ports 8402CQ GSA version EC8404009 E6GS 2 100G QSFP28 ports Note The 8402CQ ESM can operate only on the VS...

Страница 28: ...c discharge always wear an antistatic wrist strap connected to an ESD jack Always place the modules on appropriate antistatic material Support the module from underneath with two hands Do not touch co...

Страница 29: ...Apply gentle pressure anywhere on the faceplate to fully insert the module and then screw the module in to ensure a good connection and to secure it to the chassis Ethernet Switch Module December 2017...

Страница 30: ...ave either a module or a module bay cover in each bay to ensure proper ventilation Leaving a module bay unpopulated or uncovered impairs the ability of the fans to cool the chassis Hot swap of VSP 840...

Страница 31: ...24XS or 8408QQ The rest of the configuration continues to work as original until the replacement ESM comes online When the replacement ESM is online the previous configuration for that slot is removed...

Страница 32: ...slot slot 40G channelization Channelization allows you to configure each 40Gbps QSFP ports to operate as four separate 10Gbps ports You can use QSFP to four SFP breakout cables or QSFP transceivers w...

Страница 33: ...g measures before you connect data cables to the device Always use antistatic wrist straps Make sure you adjust the strap to provide good skin contact Ensure that you properly ground work surfaces and...

Страница 34: ...pecifications for the individual switches in this series Ensure that the area where you install the switch and where it operates meets these requirements Warning To avoid bodily injury from hazardous...

Страница 35: ...15 6 years 800W AC Power Supply 361 361 hours 800W DC Power Supply 536 691 hours Chassis 241 723 hours ESMs 8424GS 676 000 hours 8424GT 857 000 hours 8424XS 691 864 hours 8424XT 582 142 hours 8408QQ 6...

Страница 36: ...ch If any components are missing contact Extreme Networks 1 VSP 8000 Series switch 2 Rack mounting hardware that includes Rack mount brackets Screws to attach brackets to the switch Screws to secure t...

Страница 37: ...replaceable fan modules 6 Documentation Note A 300mm 900mm slide rack mounting kit is available as an option Installing the VSP 8000 Series in an equipment rack Note The instructions in this section...

Страница 38: ...ng brackets cannot support multiple units For a translation of this statement see Translations of safety messages on page 90 Using the optional slide rack mount kit The Universal Slide Rack Mount Kit...

Страница 39: ...n for a 300mm 600mm equipment rack This configuration comes with the short rear bracket installed The slide rail actually consists of two separate rails that slide into each other Rack rail This rail...

Страница 40: ...rackets Short rear bracket The slide rail kit comes with this bracket installed for the 300mm 600mm default configuration Figure 15 Short rear bracket Installing the Virtual Services Platform 8000 Ser...

Страница 41: ...ows the extension bracket and the long rear bracket Both are used for a 600mm 900mm configuration Figure 16 Extension and long rear brackets Locks and latches This section describes the locks and latc...

Страница 42: ...ock This feature is on the front end of the chassis rails and is used to lock the switch in the home position of the equipment rack Figure 18 Thumbscrew lock Installing the Virtual Services Platform 8...

Страница 43: ...e white release latches to remove a switch from an equipment rack if necessary Figure 19 White release latch Blue release latch This latch is a blue plastic tab that is also on the chassis rail Use th...

Страница 44: ...itch in a rack and then pull the switch out this mechanism automatically locks the slide rail in a fully extended position Retaining latch These latches are on the front and back of the slide rails Us...

Страница 45: ...o the holes in the rack For racks with large round holes the pin block retracts halfway when you insert the rail into the rack For racks with small round holes the pin block retracts all the way when...

Страница 46: ...features Procedure 1 Disconnect the power cord from the switch 2 Open the shipping carton and remove the bag of screws and the two slides used in 300mm 600mm racks Note The 300mm 600mm slides are the...

Страница 47: ...b Pull the inner chassis rail and slide it out as far as you can Installing the VSP 8000 Series in an equipment rack December 2017 Installing the VSP 8000 Series 47...

Страница 48: ...ed on the lock and pull the chassis rail out of the rack rail 4 Lift the blue locking mechanism on the rack rail to slide the outer section back into the main section Installing the Virtual Services P...

Страница 49: ...sis rail with the thumbscrew lock towards the front and position the rail over the standoffs on the chassis b Slide the chassis rail to the rear until the rail locks into the standoffs Installing the...

Страница 50: ...h the black retaining latch is facing front b Adjust the length of the rack rail so it fits the rack depth by loosening the two screws on the rack rail and adjusting the length Make sure the screws ar...

Страница 51: ...ommodates three different rack types In the default position the pin block fits into racks with square holes When retracted halfway it fits into racks with large round holes When fully retracted it fi...

Страница 52: ...these steps for the rack rail on the other side of the frame 7 Use the following steps to install the switch in the equipment rack to complete the installation a Insert the chassis rails on the switc...

Страница 53: ...lide it out until the lock shown above engages To slide the switch back into the rack push the blue release latches on the chassis rails towards the back and slide the switch into the frame 8 Connect...

Страница 54: ...section to familiarize yourself with the slide components and features Procedure 1 Disconnect the power cord from the switch 2 Open the shipping carton The 300mm 600mm slides are the default configur...

Страница 55: ...b Pull the inner chassis rail and slide it out as far as you can Installing the VSP 8000 Series in an equipment rack December 2017 Installing the VSP 8000 Series 55...

Страница 56: ...ed on the lock and pull the chassis rail out of the rack rail 4 Lift the blue locking mechanism on the rack rail to slide the outer section back into the main section Installing the Virtual Services P...

Страница 57: ...sis rail with the thumbscrew lock towards the front and position the rail over the standoffs on the chassis b Slide the chassis rail to the rear until the rail locks into the standoffs Installing the...

Страница 58: ...curing the short rear bracket to the rack rail This bracket is for 300mm 600mm equipment racks only and is not used in this installation Save the bracket for possible future use Installing the Virtual...

Страница 59: ...he extension bracket and the long rear bracket Use these brackets to extend the rack rail for 600mm 900mm racks Installing the VSP 8000 Series in an equipment rack December 2017 Installing the VSP 800...

Страница 60: ...ssible b Note the order and position of how the components are installed The extension bracket with the flat side down goes on top of the rack rail and then the long rear bracket slides into the exten...

Страница 61: ...he rack rail by inserting the screws from the rack rail side and then into the extension bracket The following figure shows the extension bracket attached to the rack rail Installing the VSP 8000 Seri...

Страница 62: ...he end of the long rear bracket f Lift the blue locking mechanism and slowly slide the rail back into the main assembly This exposes a window over the screw holes so you can install the remaining thre...

Страница 63: ...rail so that the end with the black retaining latch is in the front of the rack b Adjust the length of the rack rail so it fits the rack depth by sliding the long rear bracket into the extension brack...

Страница 64: ...mmodates three different rack types In the default position the pin block fits into racks with square holes When retracted halfway it fits into racks with large round holes When fully retracted it fit...

Страница 65: ...t these steps for the rack rail on the other side of the frame 11 Use the following steps to install the switch in the equipment rack to complete the installation a Insert the chassis rails on the swi...

Страница 66: ...a rack slide it out until the lock shown above engages To slide the switch back into the rack push the blue locks on the chassis rails towards the back and slide the switch into the frame 12 Connect p...

Страница 67: ...not bolted to the floor This can happen even if there are other devices installed in your equipment rack To avoid this danger refer to the guidelines in the graph below the figure If your rack meets...

Страница 68: ...e the switch from an equipment rack Important This procedure requires two people Procedure 1 Disconnect the power cord from the switch 2 Slide the switch out until the lock engages Installing the Virt...

Страница 69: ...oth of the white release locks one on each side of the chassis towards the front the person standing in front of the chassis pulls the chassis out of the rack Installing the VSP 8000 Series in an equi...

Страница 70: ...brackets in the front position without using a tray under the chassis The chassis weight will cause damage to a rack when mounted by the front panel especially in an environment with vibration or in...

Страница 71: ...ements Required Cable Description 10 100 1000BASE TX Ports The interconnect cabling must conform to the Cat5e Cat6 or Cat6e specification of the Commercial Building Telecommunications Cabling Standard...

Страница 72: ...e protective packaging 2 Verify that the transceiver is the correct model for the network configuration 3 Grasp the transceiver between your thumb and forefinger 4 Insert the transceiver into the prop...

Страница 73: ...a RXD mandatory 7 Data set ready DSR optional 8 Clear to send CTS optional can swap or link with pin 1 Note The Table 15 Console port pin assignments shows only the console signalling AC power supply...

Страница 74: ...e power supply into the slot 3 Verify that the power supply is fully seated in the slot The spring latch should engage and return to its original position Note The chassis design prevents an incorrect...

Страница 75: ...rating normally Important You can hot swap power supplies while the switch is operational One power supply is required for continued switch operation AC power supply specifications The VSP 8000 Series...

Страница 76: ...also see the following table for plug specifications Table 11 International power cord specifications Country and Plug Specification Specifications Typical Plug Continental Europe CEE7 standard VII ma...

Страница 77: ...laceable 800 W power supplies One comes with the switch and you can install a second power supply to provide redundancy and load sharing There are two power supply slots PSU1 on top and PSU2 on the bo...

Страница 78: ...000 Series does not have a power switch When you connect the DC power source to the DC power supply wiring assembly and then plug the assembly into the DC power supply the switch powers up immediately...

Страница 79: ...power inputs are connected to the correct connectors and that the switch is properly grounded before connecting it to a power source d Use a screwdriver to crimp the cables to the DC power supply wir...

Страница 80: ...warning events such as high temp high power high current or a slow fan Important You can hot swap power supplies while the switch is operational One power supply is required for continued switch oper...

Страница 81: ...power Important 12 V output rise time from 10 to 90 percent must be the maximum of 70 ms and monotonic under all defined input and output conditions Efficiency 88 minimum at 100 load level 92 minimum...

Страница 82: ...d the alarm threshold temperature value C Important The system does not shutdown when it exceeds the threshold temperature When the temperature cools by 2 below the threshold the alarm clears and the...

Страница 83: ...lowing command to determine which fan module failed show sys info fan This command shows the status of each fan module up down or Not Present when a fan is removed 3 Remove the fan module that failed...

Страница 84: ...test Warning Fiber optic equipment can emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to...

Страница 85: ...the AC input has been disconnected Fan Amber steady A fan module has been removed Amber blinking A fan module has failed Green steady All fan modules are operating normally Management port LED state...

Страница 86: ...Link down Green blinking Operating at 1Gbps link speed Green Solid Operating at 10Gbps link speed QSFP QSFP28 port LED state indicators The QSFP QSFP28 used in the system includes one bi colored ambe...

Страница 87: ...ingle LED labelled as Link Activity The following table shows the status of the one LED Table 18 100 1G 10G RJ45 port LED state indicators Label Color and Status Description Link Activity Off The port...

Страница 88: ...ere is data activity Green slow blinking The port is administratively disabled Channelized LED state indicators The following table describes the channelization LED state indications provided by the c...

Страница 89: ...tical to the actual LED blinking rates on the switch For more information about the LEDs and a description of the blinking rates see the preceding LED sections 40GBASE QSFP ports When a port is channe...

Страница 90: ...le dans une baie ne l empilez pas directement sur un autre Chaque module doit tre fix sa propre baie l aide des supports de montage appropri s Ces supports ne sont pas con us pour r sister plusieurs m...

Страница 91: ...installez pas le module dans une baie veillez laisser la plaque m tallique sur la baie Si vous la retirez l a ration du module ne peut pas s effectuer correctement Important Precaution Si no instala...

Страница 92: ...d alimentation En outre vous devez d gager un espace minimal dans la zone de c blage pour pouvoir y acc der facilement en cas d urgence Important Advertencia Para apagar el dispositivo debe desenchufa...

Страница 93: ...imentaci n con toma de tierra De lo contrario al tocar el interruptor puede recibir una descarga el ctrica Si no hay un circuito de toma de tierra en el enchufe puede producirse un exceso de emisiones...

Отзывы: