Summit WM3700 Wireless LAN Controller Installation Guide
13
Fan LED
Temperature Status LED
Fan LED
Event
Off
System Off / POST Start
Green Blinking
POST in Process
Green Solid
All System Fans Normal Operation
Amber Solid
Redundant Cooling Failure
System Operational
Amber Blinking
System Cooling Failure
System will be held in reset until the issue
is resolved
Temperature LED
Event
Off
System Off
Green Solid
Ambient Inlet Temperature is within
specified operating limit
Amber Solid
Ambient Inlet Temperature is near the
maximum operating temperature
During controller start up this LED will be
lit Solid Amber. This is normal behavior
and does not indicate an error.
Amber Blinking
Ambient Inlet Temperature is above the
maximum specified operating temperature
System will be held in reset until the issue
is resolved