Configuring the ExtremeXOS Switch Software

To initialize the ReachNXT 100-8t, perform the following steps on the uplinked ExtremeXOS switch:

1

If the ReachNXT 100-8t will be powered using Power over Ethernet (PoE) from the uplinked 
ExtremeXOS switch, configure PoE on the uplinked switch, using the following commands:

enable inline-power

 (enabled by default)

show inline-power

configure inline-power 

For more information about configuring PoE, refer to the 

ExtremeXOS Concepts Guide

.

2

Enable LLDP for the port to which the ReachNXT 100-8t will be connected. Use the following 
command to enable LLDP:

enable lldp ports

 [

all

 | <port_list>]

3

Connect the ReachNXT 100-8t uplink port (port 9 or 9x) to the uplinked ExtremeXOS switch. 

This step initializes the ReachNXT 100-8t. When initialization is complete, and the uplinked 
ExtremeXOS switch is detected, the MGMT LED on the ReachNXT 100-8t lights solid green.

4

To verify that the uplinked ExtremeXOS switch detects the ReachNXT 100-8t, enter the following 
command on the uplinked switch:

show lldp neighbors detailed

For an LLDP neighbor that is a ReachNXT 100-8t, the command output is similar to the following:

show lldp neighbors detailed

--------------------------------------------------------------------------

LLDP Port 4:1 detected 1 neighbor

  Neighbor: 00:04:96:1F:A8:00/9, age 29 seconds

    - Chassis ID type: MAC address (4)

      Chassis ID     : 00:04:96:1F:A8:00

    - Port ID type: ifName (5)

      Port ID     : "9"

    - Time To Live: 120 seconds

    

- System Name: "Reach 100-8t 800284-00-01 0840G-00560"

    

- System Description: "Reach 100-8t 1.6.1.6"

NOTE

To function, the ReachNXT 100-8t must be connected to an ExtremeXOS switch. The ReachNXT 100-8t only 
operates when it detects an ExtremeXOS switch connected to the uplink port via LLDP. LLDP must be enabled on 
the ExtremeXOS switch to which the ReachNXT 100-8t is connected. The ReachNXT 100-8t disables its user ports 
if no ExtremeXOS switch is detected, or the uplink port is down. The user ports are re-enabled when the uplink port 
is up, and an ExtremeXOS switch is detected.