112
Advanced System Diagnostics and Troubleshooting Guide
Limited Operation Mode and Minimal Operation Mode
Triggering Limited Operation Mode
On a BlackDiamond system with a single MSM, if a diagnostics test detects errors or if the POST fails,
the system goes into limited operation mode. Similarly, on a Summit or Alpine system, if a diagnostics
test detects errors, the Summit or Alpine switch will go into limited operation mode. When a failure
occurs, the system retains an error code.
In limited operation mode, you must use the
clear log diag-status
command to clear the hardware
error code so that the module—in the case of a BlackDiamond system, or the switch—in the case of an
Alpine or Summit system, can be brought up after the next reboot.
Bringing a Switch Out of Limited Operation Mode
To bring a switch out of limited operation mode, perform these steps:
1
Begin collecting background information that might help isolate the causes of the problem and
contact Extreme Networks technical support and notify them about the problem.
a
Note any recent hardware or configuration changes.
b
Create a detailed description of all the known symptoms.
c
Capture the output from the
show log
command.
d
Capture the output from the
show diagnostics
command.
e
On a sheet of paper, write down the state of all LEDs on the switch.
2
Use the
clear log diag-status
command to clear the hardware error codes.
3
Use the
reboot
command to reboot the system.
4
Use the
show tech
CLI command to collect system information.
5
Send all of the information about the problem to Extreme Networks technical support.
Minimal Operation Mode
If the system reboots due to a failure that persists after the reboot, the system will reboot again when it
detects the failure again, and will continue that behavior across an endless cycle of reboots—referred to
as a
reboot loop
.
The ExtremeWare reboot loop protection feature provides a mechanism to detect a reboot loop and
force the system into
minimal operation mode
. In minimal mode, only the CPU, NVRAM, management
port, a minimal set of system tasks, and a minimal subset of CLI commands are active.
Triggering Minimal Operation Mode
To protect against reboot loops, you can configure reboot loop protection using the command:
configure reboot-loop-protection threshold <time-interval> <count>
If the switch reboots the specified number of times (
<count>
) within the specified time interval
(
<time-interval>
), the switch stops rebooting and comes up in minimal operation mode.
For more information on the use of this command, see
“Configuring Reboot Loop Protection” on
page 43
.
Содержание ExtremeWare Version 7.8
Страница 8: ...8 Advanced System Diagnostics and Troubleshooting Guide Contents...
Страница 14: ...14 Advanced System Diagnostics and Troubleshooting Guide Introduction...
Страница 24: ...24 Advanced System Diagnostics and Troubleshooting Guide i Series Switch Hardware Architecture...
Страница 48: ...48 Advanced System Diagnostics and Troubleshooting Guide Software Exception Handling...
Страница 102: ...102 Advanced System Diagnostics and Troubleshooting Guide Additional Diagnostics Tools...
Страница 110: ...110 Advanced System Diagnostics and Troubleshooting Guide Troubleshooting Guidelines...
Страница 114: ...114 Advanced System Diagnostics and Troubleshooting Guide Limited Operation Mode and Minimal Operation Mode...
Страница 120: ...120 Advanced System Diagnostics and Troubleshooting Guide Index...