Figure 189: STK-RPS-150PS Installation in an STK-RPS-150CH8 Shelf
1 = STK-RPS-150CH8 shelf
3 = Captive screws (2)
2 = STK-RPS-150PS power supply
4 = Shelf power supply slot
3 Fasten the power supply to the RPS shelf using the captive screws on the PSM front panel.
4 Repeat the two previous steps for each additional power supply.
5 Proceed to
Installing the RPS Shelf into the Rack
Installing the RPS Shelf into the Rack
To install an STK-RPS-150CH2 or STK-RPS-150CH8 into a 19-inch (48.3 cm) rack, you need the following:
•
For the STK-RPS-150CH2: four customer-supplied screws to fasten the shelf to the rack rails.
•
For the STK-RPS-150CH8: ten customer-supplied screws to fasten the shelf to the rack rails.
After installing the power supplies as described in
Installing an STK-RPS-150PS in an RPS Shelf
on page
242, rack mount the RPS shelf as follows:
1 Refer to the installation guidelines (
Guidelines for Rack Mount Installation
).
2 Install the RPS shelf into the rack (
on page 244).
3 Connect the RPS cables and AC power cords of the power supplies (
Installing External Power Supplies
ExtremeSwitching and Summit Switches: Hardware Installation Guide
243